• 제목/요약/키워드: Voltage Frequency

검색결과 5,126건 처리시간 0.033초

능동보조회로를 이용한 전압형 PWM 인버어터 시스템에서의 커먼 모드전압과 고주파 누설전류 억제방법에 관한 연구 (Reduction of common mode voltage and high frequency leakage current generated by the PWM voltage source inverter using common mode voltage damper)

  • 전진휘;박성준;김광태;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.373-376
    • /
    • 1999
  • This paper propose a "common mode voltage damper" that is capable of reducing the common mode voltage produced in the PWM VSI. An push-pull circuits and high frequency leakage current damper[1] are incorporated into the "common mode voltage damper", the design method of which is presented. Effect of "common mode voltage damper" is simulated in this paper verifies the viability and effectiveness in 2.2kW induction motor drive using IGBT inverter. Simulated results show that "common mode voltage damper" makes significant contributions to reducing a high frequency leakage current.ducing a high frequency leakage current.

  • PDF

스크린 인쇄 기법에 의해 제작된 옥외 광고용 분산형 무기 EL 램프의 색좌표 변화와 광고 효과 (Effects of Advertising according to the Altering Color Coordinates of the Outdoor Billboards a Inorganic Powder EL Lamp That was made by Screen Printing Technique)

  • 문길환;이광숙
    • 한국인쇄학회지
    • /
    • 제30권1호
    • /
    • pp.47-58
    • /
    • 2012
  • The inorganic powder EL lamp was made by screen printing technique with a phosphor ink and a dielectric ink. Value of color coordinates X and Y increased under the condition of supplying driving power to the inorganic powder EL lamp and changing voltage with constant frequency. When frequency was changed under the constant voltage, value of color coordinates X and Y were decreased with increasing frequency. However, level of change of color coordinates X was different from color coordinates Y. When voltage was increased under constant frequency, changing degree of color coordinates X and Y shows similarity. But under the constant voltage with changing frequency, color coordinates X and Y were differently changed that degree of change of color coordinates Y showed five times more than that of color coordinates X. As increasing thickness of phosphor ink and dielectric ink, level of voltage and frequency, color coordinates X and Y were slightly changed. According to the thickness of phosphor ink and dielectric ink, and level of voltage and frequency, color coordinate of color light was changed. Frequency was most important element influencing on the change of color coordinate.

전류 컨베어 회로를 이용한 차동전압-주파수 변환기의 설계 (Design of Differential Voltage-to-Frequency Converter Using Current Conveyor Circuit)

  • 최진호
    • 한국정보통신학회논문지
    • /
    • 제15권4호
    • /
    • pp.891-896
    • /
    • 2011
  • 이 논문에서는 전류 컨베이어 회로를 이용하여 입력 전압의 차에 비례하는 주파수 신호를 생성하는 회로를 설계하였다. 설계된 회로는 HSPICE를 이용하여 회로의 동작을 분석하였으며, 입력 전압 차는 수V에서 수mV 단위까지 변화시키면서 출력 주파수를 시뮬레이션하였다. 회로의 시뮬레이션 결과 이론적인 계산값과 비교하였을 때 에러는 -1.9%에서 +1.8% 이내였다.

AC 전압원에서 주파수 및 전압변화에 따른 양극산화 알루미늄 박막성장 특성 (Alumina characteristic fabricated by AC voltage at different potential and frequency)

  • 이정택;최재호;김근주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.268-268
    • /
    • 2010
  • AC anodizing on aluminum foil was investigated by the variation of AC voltage and frequency. The voltage and frequency were applied in the range of approximately 40~200V, 0~400Hz. The porous alumina film was formed and the growth rate of oxide film is increased with frequency. The structural property was analyzed by SEM and XRD. SEM results show the approximate relation between frequency, voltage and growth rate. The AC voltage effect on the structural modulation of porous alumina indicates that AC anodizing is useful for the application to nanocapacitor material.

  • PDF

PLL을 이용한 무선 전력전송 장치의 공진 주파수의 계측 및 주파수 제어 (Measurement and Control of the Resonance Frequency for the Transcutaneous Energy Transmission System (TET) Using the Phase Locked Loop Circuit (PLL))

  • 최성욱;심은보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1613-1616
    • /
    • 2008
  • A Transcutaneous Energy Transmission System (TET) has been developed for the wireless energy transmission with two magnetically coupled coils. A resonance circuit is used to raise the induced voltage and current of the secondary coil. Its resonance frequency depends on the internal resistance of circuit and the transferred energy. Because the transferred energy usually changes in wide range, the output voltage is unstable and the energy transferring efficiency decrease. A push-pull class E amplifier is usedto generate high frequency AC voltage. To maintain proper resonance frequency, the voltage output of the amplifier was continuously monitored and adjusted to the optimized resonance frequency. Because of its high frequency (370 kHz), a phase lockedloop circuit and a comparator are used to monitor the output waveform. The results of experimentaldata show that the PLL circuit can increase the transmission efficiency and stabilize the output voltage of TET.

  • PDF

교류구동방식에 의한 형광 OLED의 주파수 응답 특성 (Frequency Response Characteristics of Fluorescent OLED with Alternating Current Driving Method)

  • 서정현;주성후
    • 한국전기전자재료학회논문지
    • /
    • 제32권1호
    • /
    • pp.40-46
    • /
    • 2019
  • To study the frequency response characteristics of alternating-current-driven organic light-emitting diodes (OLEDs), we fabricated blue-fluorescent OLEDs and analyzed their electroluminescent characteristics according to the alternating current voltage and frequency. The luminance-frequency characteristics of alternating-current-driven OLED was similar to that of a low-pass filter, and the luminance of high-voltage OLED decreased at higher frequency than low-voltage OLED. The luminance characteristics of the OLED according to the frequency is due to the capacitive reactance in the OLED, generated during the alternating current driving. The frequency response characteristics of the OLED according to the voltage is due to the decrease in internal resistance of the organic layer. In addition, the negative voltage component of the alternating current did not affect the frequency response of the OLED. Therefore, the electroluminescent characteristics of OLED with an alternating current power of 60 Hz are not influenced by the frequency.

Common Mode Voltage Cancellation in a Buck-Type Active Front-End Rectifier Topology

  • Aziz, Mohd Junaidi Abdul;Klumpner, Christian;Clare, Jon
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.276-284
    • /
    • 2012
  • AC/AC power conversion is widely used to feed AC loads with a variable voltage and/or a variable frequency from a constant voltage constant frequency power grid or to connect critical loads to an unreliable power supply while delivering a very balanced and accurate sinusoidal voltage system of constant amplitude and frequency. The load specifications will clearly impose the requirements for the inverter stage of the power converter, while wider ranges of choices are available for the rectifier. This paper investigates the utilization of a buck-type current source rectifier as the active front-end stage of an AC/AC converter for applications that require an adjustable DC-link voltage as well as elimination of the low-frequency common mode voltage. The proposed solution is to utilize a combination of two or more zero current vectors in the Space Vector Modulation (SVM) technique for Current Sources Rectifiers (CSR).

Novel Carrier-Based PWM Strategy of a Three-Level NPC Voltage Source Converter without Low-Frequency Voltage Oscillation in the Neutral Point

  • Li, Ning;Wang, Yue;Lei, Wanjun;Niu, Ruigen;Wang, Zhao'an
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.531-540
    • /
    • 2014
  • A novel carrier-based PWM (CBPWM) strategy of a three-level NPC converter is proposed in this paper. The novel strategy can eliminate the low-frequency neutral point (NP) voltage oscillation under the entire modulation index and full power factor. The basic principle of the novel strategy is introduced. The internal modulation wave relationship between the novel CBPWM strategy and traditional SPWM strategy is also studied. All 64 modulation wave solutions of the CBPWM strategy are derived. Furthermore, the proposed CBPWM strategy is compared with traditional SPWM strategy regarding the output phase voltage THD characteristics, DC voltage utilization ratio, and device switching losses. Comparison results show that the proposed strategy does not cause NP voltage oscillation. As a result, no low-frequency harmonics occur on output line-to-line voltage and phase current. The novel strategy also has higher DC voltage utilization ratio (15.47% higher than that of SPWM strategy), whereas it causes larger device switching losses (4/3 times of SPWM strategy). The effectiveness of the proposed modulation strategy is verified by simulation and experiment results.

순시전력 합성 개념을 이용한 가상주파수 3상 실효전압 계측기법 (3-Phase RMS Voltage Measurement Method of Virtual Frequence using Instantaneous Power Component Concept)

  • 박성미;양지훈;박성준
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.251-257
    • /
    • 2019
  • This paper proposes a new measurement method using virtual power concept to measure the effective value of 3-phase voltage with variable frequency. The conventional effective value measurement method uses a method of integrating data sampled during one or half cycle of the power voltage and averaging it. In this method, since the effective voltage is calculated every cycle, a time delay occurs in the measured effective voltage and it is s a problem to measure the effective value of a device whose frequency varies from time to time, such as a generator. The proposed 3-phase voltage rms measurement method has an advantage that it can measure accurate voltage RMS value regardless of measurement frequency variation. In particular, there is an advantage in that it is possible to measure a 3-phase effective voltage rather than an average value of the effective voltage of each phase in a 3-phase unbalance voltage. In addition, the validity of the proposed method is verified by using the Psim simulation tool and the experimental results are analyzed by applying the proposed measurement algorithm to the actual three phase synchronous generator voltage measurement experiment.

Accurate Voltage Parameter Estimation for Grid Synchronization in Single-Phase Power Systems

  • Dai, Zhiyong;Lin, Hui;Tian, Yanjun;Yao, Wenli;Yin, Hang
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1067-1075
    • /
    • 2016
  • This paper presents an adaptive observer-based approach to estimate voltage parameters, including frequency, amplitude, and phase angle, for single-phase power systems. In contrast to most existing estimation methods of grid voltage parameters, in this study, grid voltage is treated as a dynamic system related to an unknown grid frequency. Based on adaptive observer theory, a full-order adaptive observer is proposed to estimate voltage parameters. A Lyapunov function-based argument is employed to ensure that the proposed estimation method of voltage parameters has zero steady-state error, even when frequency varies or phase angle jumps significantly. Meanwhile, a reduced-order adaptive observer is designed as the simplified version of the proposed full-order observer. Compared with the frequency-adaptive virtual flux estimation, the proposed adaptive observers exhibit better dynamic response to track the actual grid voltage frequency, amplitude, and phase angle. Simulations and experiments have been conducted to validate the effectiveness of the proposed observers.