• Title/Summary/Keyword: Vertical distribution pattern

Search Result 237, Processing Time 0.026 seconds

The FEM Analysis on the Crestal Cortical Bone around the Implant according to the Cancellous Bone Density and Loading Positions (임프란트 매식시 해면골질의 차이에 따른 치밀골 상 응력분석)

  • Jeung, Sin-Young;Kim, Chang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • This study was performed to compare the stress distribution pattern in the crestal cortical bone and cancellous bone using 3-dimensional finite element stress analysis when 2 different Young's modulus(high modulus, model 1; low modulus, model 2) of cancellous bone was assumed. For the analysis, a finite element model was designed to have two square-threaded implants fused together and located at first and second molar area. Stress distribution was observed when vertical load of 200N was applied at several points on the occlusal surfaces of the implants, including central fossa, points 1.5mm, 2mm, 3mm and 3.5mm buccally away from central fossa. The results were as follows; 1. In both model, the maximum Von-Mises stress in the crestal cortical bone was greater when the load was applied at the central point, points 1.5mm and 2mm buccally away from central fossa than other cases. 2. In the cortical bone around first and second molar, model 2 showed greater Von-Mises stress than model 1. It is concluded that when the occlusal contact is afforded, the distribution of stress varies depending on the density of cancellous bone and the location of loading. More favorable stress distribution is expected when the contact load is applied within the diameter of fixtures.

Influence of changing various parameters in miniscrew-assisted rapid palatal expansion: A three-dimensional finite element analysis

  • Yoon, Soungjun;Lee, Dong-Yul;Jung, Seok-Ki
    • The korean journal of orthodontics
    • /
    • v.49 no.3
    • /
    • pp.150-160
    • /
    • 2019
  • Objective: This study aimed to analyze the effect of changing various parameters of the bone-borne rapid palatal expander (RPE) using the finite element method (FEM). Methods: In eight experimental groups, we investigated the effect of the number, position, and length of miniscrews; positional changes of the expander; and changes in the hook length on maxillary expansion. In finite element analysis, we compared the magnitude and distribution of stress, and the displacement changes following expansion of the bone-borne RPE. Results: When we compared the number and position of miniscrews, placing miniscrews in the anterior and posterior sides was advantageous for maxillary expansion in terms of stress distribution and displacement changes. Miniscrew length did not significantly affect stress distribution and displacement changes. Furthermore, anteroposterior displacement of the expander did not significantly affect transverse maxillary expansion but had various effects on vertical changes of the maxilla. The maxilla rotated clockwise when the miniscrews were placed in the anterior region. The hook length of the expander did not show consistent results in terms of changes in stress distribution and magnitude or in displacement changes. Conclusions: The findings of this study suggest that changes in the location and length of the miniscrews and displacement of the bone-borne RPE could affect the pattern of the maxillary expansion, depending on the combination of these factors.

STRESS DISTRIBUTION PATTERN OF THE DIFFERENT DIAMETER AND LENGTH OF SHORT IMPLANTS ACCORDING TO THE BONE QUALITY : 3-D FINITE ELEMENTS ANALYSIS (상이한 골질과 제원에 따른 짧은 임프란트의 응력 분포: 3차원 유한 요소 분석)

  • Kim, Han-Koo;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.116-126
    • /
    • 2009
  • The use of short implants has been accepted risky from biomechanical point of view. However, short implants appear to be a long term viable solution according to recent clinical reports. The purpose of this study was to investigate the effect of different diameter and length of implant size to the different type of bone on the load distribution pattern. Stress analysis was performed using 3-dimensional finite element analysis(3D-FEA). A three-dimensional linear elastic model was generated. All implants modeled were of the various diameter(${\phi}4.0$, 4.5, 5.0 and 6.0 mm) and varied in length, at 7.0, 8.5 and 10.0 mm. Each implant was modeled with a titanium abutment screw and abutment. The implants were seated in a supporting D2 and D4 bone structure consisting of cortical and cancellous bone. An amount of 100 N occlusal load of vertical and $30^{\circ}$ angle to axis of implant and to buccolingual plane were applied. As a result, the maximum equivalent stress of D2 and D4 bones has been concentrated upper region of cortical bone. As the width of implant is increased, the equivalent stress is decreased in cancellous bone and stress was more homogeneously distributed along the implants in all types of bone. The short implant of diameter 5.0mm, 6.0mm showed effective stress distribution in D2 and D4 bone. The oblique force of 100N generated more concentrated stress on the D2 cortical bone. Within the limitations of this study, the use of short implant may offer a predictable treatment method in the vertically restricted sites.

A PHOTOELASTIC STUDY OF STRESS DISTRIBUTIONS AROUND SURROUNDING BONE TISSUES OF IMPLANTS DEPENDING UPON THE LENGTH OF IMPLANT FIXTURES SUPPORTING FIXED BRIDGES (고정성 가공의치를 지지하는 임프란트의 길이에 따른 임플란트 주위 골조직에서의 응력분산에 관한 광탄성 연구)

  • Bae Hyong-Su;Cho Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.4
    • /
    • pp.611-621
    • /
    • 1992
  • The Present study was performed to evaluate the stress distribution patterns of bone tissues around two Branemark implant fixtures with varying lengths. Six models were used with the combination of 10mm, 7mm, 5mm Branemark implant fixture analogs. The load distribution characteristics of surrounding bone tissues were observed under 64kg vertical static loading on central part of fixed bridge using 2 dimensional photoelastic technique. Through observing the pattern of stress distribution around the implant fixtures, I got the results as follow : 1. Stress distribution pattern of model I(10mm, 10mm) was best among those of six models. 2. When two fixtures were in equal length, stress was increased in proportion to the reduction of implant surface area. 3. When two fixtures were in unequal length, stress was concentrated on the neck portion of the shorter one.

  • PDF

Finite Element Stress Analysis of Implant Prosthesis According to Friction Fit or Slip Fit of Internal Connection System between Implant and Abutment (임플랜트와 지대주 간 내측연결 시스템에서 Friction Fit와 Slip Fit에 따른 유한요소 응력분석)

  • Jang, Doo-Ik;Jeong, Seung-Mi;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.2
    • /
    • pp.113-132
    • /
    • 2005
  • The purpose of this study was to assess the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to a friction-fit joint (Astra; Model 1) or slip- fit joint (Frialit-2; Model 2) in the internal connection system under vertical and inclined loading using finite element analysis. In conclusion, in the internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to the abutment connection form had difference among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the abutment post. The magnitude of the stress distributed in the supporting bone, the implant fixture, the abutment and the abutment screw was higher in the friction-fit joint than in the slip-fit joint. But it is considered that the further study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

Species Composition and Vertical Distribution Pattern of Fish in Rock Tidal Pools at Mohang, Taeanhaean National Park (태안해안국립공원 모항 암반조간대 웅덩이의 어류 종조성과 수직분포)

  • Choi, Youn;Lee, Heung-Heon
    • Korean Journal of Ichthyology
    • /
    • v.25 no.4
    • /
    • pp.227-233
    • /
    • 2013
  • Speceis composition and distribution by altitude of fish in the rock tide pools in Taean were determined using montly samples collected in the 9 tide pools from January to December 2010. Among 16 species collected, a forktongue goby Chaenogobius annularis was dominant accounting for 34.6% in the total number of individuals, and followed by Dictysoma burgeri (22.0%), Sebastes schlegelii (6.9%) and Tridentiger trigonocephalus (6.8%). A resident fish Dictyosoma burger occurred at all tide pools, and Chasmichthys dolichognathus was dominant in the upper tide pools and was collected throughout the study period. The resident fish is more abundant than the transient fish and occasional fish accounted for 61.4%, 14.2% and 24.4% in biomass, respectively.

Vertical distribution and vascular plants in the Gakho mountain (Yeongdong-gun), Korea (각호산(영동군)의 관속식물과 수직분포)

  • Jung-Hyun Kim;Jin-Suk Kim;Sookyung Shin;Tae-Im Heo;Young Hoon Kim;Sunghyuk Park;Jin-Seok Kim
    • Korean Journal of Environmental Biology
    • /
    • v.41 no.1
    • /
    • pp.60-88
    • /
    • 2023
  • This study was conducted to investigate the vertical distribution and vascular plants in the Gakho mountain. Form the results of three field surveys from May 2022 to September 2022, a total of 478 total taxa, representing 426 species, 11 subspecies, 35 varieties, four forms, and two hybrids were identified, which were categorized in 282 genera and 94 families. We identified the elevational distribution ranges of 398 taxa of vascular plants. Among them, 19 taxa were endemic to Korea, one taxon was identified as a rare plant. The floristic target plants amounted to 72 taxa, specifically two taxa of grade V, two taxa of grade IV, 16 taxa of grade III, 27 taxa of grade II, and 25 taxa of grade I. Further, 71 taxa were identified as northern lineage plants. A total of 19 taxa of alien plants were identified, with a Naturalized Index of 4.0%, an Urbanization Index of 6.6%, and three plants that disturbed the ecosystem. The result of analyzing the pattern of species richness showed a reversed hump shape with minimum richness at mid-high elevation. A cluster analysis showed a high degree of similarity between adjacent elevation sections that are geographically adjacent with similar habitat environments. Warmth index in the Gakho mountain ranged from 57.2℃·month to 84.2℃·month. Our results provide basic data on vascular plants and valuable information on elevational distribution ranges of current plant species in the Gakho mountain, which could serve as a baseline for comparison of the shifts in elevation under future climate change.

Stiffness Reduction Effect of Vertically Divided Reinforced Concrete Shear Walls Under Cyclic Loading (반복하중을 받는 수직분할된 철근콘크리트 전단벽의 강성저감효과)

  • Hwangbo, Dong-Sun;Son, Dong-Hee;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.103-110
    • /
    • 2022
  • The purpose of this study is to experimentally evaluate the stiffness and strength reduction according to the reinforcing bar details of the vertically divided reinforced concrete shear walls. To confirm the effect of reducing strength and stiffness according to vertical division, four real-scale specimens were fabricated and repeated lateral loading tests were performed. As a result of the experiment, it was confirmed that the strength and stiffness were decreased according to the vertical division. In particular, as the stiffness reduction rate is greater than the strength reduction rate, it is expected that safety against extreme strength can be secured when the load is redistributed according to vertical division. As a result of checking the crack pattern, a diagonal crack occurred in the wall subjected to compression control among the divided walls. It was confirmed that two neutral axes occurred after division, and the reversed strain distribution appeared in the upper part, showing the double curvature pattern. In future studies, it is necessary to evaluate the stiffness reduction rate considering the effective height of the wall, to evaluate additional variables such as wall aspect ratio, and to conduct analytical studies on various walls using finite element analysis.

Sources and Distributions of Dissolved Organic Matter by Fluorescence Method in the Northeastern Pacific Ocean (북동태평양에서 형광 기법을 이용한 용존유기물의 기원 및 분포)

  • Son, Ju-Won;Son, Seung-Kyu;Ju, Se-Jong;Kim, Kyeong-Hong;Kim, Woong-Seo;Park, Yong-Chul
    • Ocean and Polar Research
    • /
    • v.29 no.2
    • /
    • pp.87-99
    • /
    • 2007
  • This study was conducted to understand the source and behavior of organic matter using the fluorescent technique (excitation-emission matrix) as a part of environmental monitoring program in the Korea manganese nodule mining site in the Northeastern Pacific Ocean. Water samples were collected at $0^{\circ},\;6^{\circ}N$, and $10.5^{\circ}N$ along $131.5^{\circ}W$ in August 2005. The concentration of total organic carbon (TOC) ranged from 58.01 to $171.93\;{\mu}M-C$. The vertical distribution of TOC was characterized as higher in the surface layer and decreased with depth. At $6^{\circ}N$, depth-integrated (from surface to 200 m depth) TOC was $337.1\;gC/m^2$, which was 1.4 times higher value than other stations. The exponential decay curve fit of vertical profile of TOC indicated that 59% of organic carbon produced by primary production in the surface layer could be decomposed by bacteria in the water column. Dissolved organic matter is generally classified into two distinctive groups based on their fluorescence characteristics using three-dimensional excitation/emission (Ex/Em) fluorescence mapping technique. One is known as biomacromolecule (BM; protein-like substance; showing max. at Ex 280/Em 330), mainly originated from biological metabolism. The other is geomacromolecule (GM; humic-like substance; showing max. at Ex 330/Em 430), mainly originated from microbial degradation processes. The concentration of BM and GM was from 0.42 to 7.29 TU (tryptophan unit) and from 0.06 to 1.81 QSU (quinine sulfate unit), respectively. The vertical distribution of BM was similar to that of TOC as high in the surface and decreased with depth. However, the vertical distribution of GM showed the reverse pattern of that of BM. From these results, it appeared that BM occupied a major part of TOC and was rapidly consumed by bacteria in the surface layer. GM was mainly transformed from BM by microbial processes and was a dominant component of TOC in the deep-sea layer.

Analysis of Pattern Change of Real Transaction Price of Apartment in Seoul (서울시 아파트 실거래가의 변화패턴 분석)

  • Kim, Jung Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.1
    • /
    • pp.63-70
    • /
    • 2014
  • This study is to analyze impact of geography and timing on the real transactions prices of apartment complexes in Seoul using data provided by the Ministry of Land, Infrastructure and Transport. The average real transactions and location data of apartment complex was combined into the GIS data. First, the pattern of apartment real transaction price change by period and by area was analyzed by kriging, the one of the spatial interpolation technique. Second, to analyze the pattern of apartment market price change by administrative district(administrative 'Dong' unit), the average of market price per unit area was calculated and converted to Moran I value, which was used to analyze the clustering level of the real transaction price. Through the analysis, spatial-temporal distribution pattern can be found and the type of change can be forecasted. Therefore, this study can be referred as of the base data research for the housing or local policies. Also, the regional unbalanced apartment price can be presented by analyzing the vertical pattern of the change in the time series and the horizontal pattern of the change based on GIS.