1 |
Levine RA, et al. A multicenter retrospective analysis of ITI implant system used for single-tooth replacements: Preliminary results at six or more months of loading. Int J Oral Maxillofacial Implants 1997; 12: 237-242
|
2 |
Chung KM, Chung CH, Jeong SM. Finite element analysis of implant prostheis according to platform width of fixture. J Korean Acad Prosthodont 2003; 41:674-688
|
3 |
Morimoto K, Kihara A, Takeshita F, Suetsugu T. An experimental study on the tissue compatibility of the titanium blade-vent implant coated with HAP-alumina in the semi- functional state. J Oral Implantol 1987; 13:387-401
|
4 |
Rangert B, Jemt T, Jomeus L. Forces and moments on Branemark implants. Int J Oral Maxillofac Implants 1989; 4:241-247
|
5 |
Weinberg LA. Force distribution in splinted anterior teeth. Oral Surg Oral Med Oral Pathol. 1957; 10:484-494
DOI
ScienceOn
|
6 |
Clelland NL, Lee JK, Bimbenet OC, Gilat A. Use of an axisymmetric finite element method to compare maxillary bone variables for a loaded implant. J Prosthodont 1993; 2:183-189
DOI
ScienceOn
|
7 |
Akca K, Iplikcioglu H. Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II : 3-D finite element stress analysis. Implant Dent 2001; 10:239-245
|
8 |
Norton MR. Assessment of cold welding properties of internal conical interface two commercially available implant system. J Prosthet Dent 1999; 81:159-166
DOI
PUBMED
ScienceOn
|
9 |
Sutter F, Webber HP, Sorensen J, Belser U. The new restorative concept of the ITI dental implant system: design and engineering. Int J Perodont Rest Dent 1993; 13:409-431
|
10 |
Patterson EA, Burguete RL, Thoi MH, Johns RB. Distribution of load in an oral orosthesis system: an in vitro study. Int J Oral Maxillofac Implants 1995; 10:552-560
|
11 |
Rangert B, Krogh PHJ, Langer B, van Roekel NB. Bending overload and implant fracture: A retrospective clinical analysis. Int J Oral Maxillofac Implants 1995; 10:326-334
|
12 |
Holmes DC, Grigsby WR, Goel VK, Keller JC. Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: A finite element stress analysis. Int J Oral Maxillofac Implants 1992; 7:450-458
|
13 |
Rangert B, Enouard F, Amoux JP, Sarment DP. Load factor control for implants in the posterior partially edentulous segment. Int J Oral Maxillofac Implants 1997; 12:360-370
|
14 |
Jemt T, Lekholm U, Grondahl K. A 3-year follow-up study of early single implant restorations ad modem Branemark, Int J Oral Perodont Rest Dent 1990; 10: 340-349
|
15 |
Mollersten L, Lockowandt P, Linden LA. Comparison of strength and failure mode of seven implant systems: An in vitro test. J Prosthet Dent 1997;78:582-591
DOI
ScienceOn
|
16 |
Merz BR. Hunenbart S, Belser UC. Mechanics of the implant-abutment connection. An 8-degree taper compared to a butt joint connection. Int J Oral Maxillofac Implants 2000; 15: 519-526
|
17 |
Krennmair G. Schmidinger S, Waldenberger O. Single-tooth replacement with frialit-2 system: A retrospective clinical analysis of 146 implants. Int J Oral Maxilofac Implanst. 2002; 17:78-85
|
18 |
Dan ET, William RL. Tissue-integrated prostheses complication. Int J Oral Maxillofac Implants 1992; 7:477-484
|
19 |
Norton MR. In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems.. J Prosthet Dent 2000; 83:567-571
DOI
PUBMED
ScienceOn
|
20 |
Weinberg LA. Force distribution in splinted posterior teeth. Oral Surg Oral Med Oral Pathol. 1957; 10:1268-1276
DOI
ScienceOn
|
21 |
Matsushita Y, Kithoh M, Mizuta K, Ikeda H, Suetsugu T. Two-dimentional FEM analysis of hydroxyapatite implants: diameter effects on stress distribution. J Oral Implantol 1990; 16:6-11
|
22 |
Jemt T, Linden B, Lekholm U. Failures and complications in 127 consecutive placed fixed partial prostheses supported by Branemark implants. Int J Oral Maxillofac Implants 1992; 7:40-44
|
23 |
Balfour A, O'Brien GR. Comparative study of antirotational single tooth abutments. J Prosthet Dent 1995; 73:36-43
DOI
ScienceOn
|
24 |
Weinberg LA. The biomechanics of force distribution in implant- supported prostheses. Int J Oral Maxillofac Implants 1993; 8:19-31
|
25 |
Boggan RS, Strong JT, Misch CE, Bidez MW. Influence of hex geometry and prosthetic table width on static and fatigue strength of dental implants. J Prosthet Dent 1999; 82:436-440
DOI
ScienceOn
|
26 |
Kim NH, Chung CH, Son MK, Back DH. A study on the fit of the implant-abutment-screw interface. J Korean Acad Prosthodont 2003; 41:503-518
|
27 |
Kirsch A, Neuendorff G, Ackermann KL, Nagel R, Durr W. Camlog connection: Requirements for a reliable implant prosthetic treament concept; tooth for tooth restoration. Quintessenz 1999; 50:1-18
|
28 |
Jemt T et al. Osseointegrated implants for single tooth replacement. A l-year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991; 6:29-36
|
29 |
Akca K, Cehreli MC, lplikcioglu H. Evaluation of the mechanical characteristics of the implant abutment complex of a reduced diameter morse taper implant: a nonlinear finite element stress analysis, Clinical Oral Implants Research 2003;14:444-455
DOI
ScienceOn
|
30 |
Haraldson T, Zarb GA. A 10-year follow-up study of the masticatory system after treatment with osseointegrated implant bridges. Scand J Dent Rec 1988; 96:243-252
|
31 |
Lum LB. A biomechanical rationale for the use of short implants. J. Oral Implantol 1991; 17:126-131
|
32 |
Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res 1997; 8:290-298
DOI
PUBMED
ScienceOn
|
33 |
Sutter F, et al. The new concept of ITI hollow-cylinder and hollow-screw implants : Part 1. Engineering and design. Int J Oral Maxilofac Implant. 1988; 3:161-172
|
34 |
Lum LB, Osier J.F. Load transfer from endosteal implants to supporting bone: An analysis using statics. Part one: Horizontal loading. J Oral Implantol 1992; 18:343-348
|