• 제목/요약/키워드: Umbilical

Search Result 653, Processing Time 0.025 seconds

Reconstruction of Scarred Umbilicus Using an Inverted C-V Flap: A Case Report (Inverted C-V 피판을 이용한 반흔 배꼽의 재건 치험례)

  • Hong, Yoon Gi;Cho, Jong Je
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.653-655
    • /
    • 2007
  • Purpose: The umbilicus is an important aesthetic component of the abdomen. Its absence is both cosmetically and psychologically distressing to the patient. Umbilical reconstruction should always be aimed at creating an umbilicus of sufficient depth and good morphology with less scarring. The C-V flap developed for nipple reconstruction was used in an inverted fashion in case of umbilical reconstruction. The aim of this article is to report our experience of scarred umbilical reconstruction using inverted C-V flap. Methods: A 22-year-old woman presented with contracted scar tissue in the umbilical region because she had undergone surgical correction of an umbilical hernia at 5 year of age. Pedicle of the inverted C-V flap was based cephalically. For enhancing depth of the umbilicus, three anchoring sutures to linea alba were done at both lateral and caudal aspects of the umbilical tube. Primary closures were done at donor sites of the V flaps and bolster sutures were done in the caudal direction of the inverted umbilical tube. Results: The patient was satisfied with the appearance of umbilicus. Major complications such as dehiscence, infection, and delayed healing did not occur. Conclusion: The inverted C-V flap is easy and simple technique, and it can produce a satisfactory reconstruction of umbilical structure.

A Study on the Hidden Type Separation Device for Missile Umbilical Connector (발사 후 은닉형 배꼽연결기 분리장치에 관한 연구)

  • Ahn, Soo-Hong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.598-606
    • /
    • 2013
  • After the missile is launched, the umbilical connector should be separated from it without any physical interference. The umbilical separation device, for this purpose, was developed by means of new concept. Using the investigation of various methods to separate the umbilical connector, a suitable method was selected and a corresponding device was designed and manufactured. To ensure the performance of the developed device, numerical analysis and performance test were conducted and correction was followed. The umbilical separation device was applied to real system operation test and its operation performance was tested. In consequence, several problems were founded, however, good results were generally obtained.

Factors Affecting Serum Lipids in Maternal and Infants Umbilical Cord Blood (산모혈과 제대혈의 혈청 지질치에 영향을 미치는 요인에 대하여)

  • 민재희;정규혁;연제덕
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.66-71
    • /
    • 1997
  • To investigate the effect of several factors on serum lipids in maternal and infants umbilical cord blood, 111 cases of newborn infants and women delivered of a child who had delivered at hospital located in Chung-Ju city from Feb. 1, 1996 to Aug. 31, 1996 were studied. The gestational ages of cases were 37 to 42 weeks and the average maternal ages were 28.1$\pm$4.25 years old without any other medical or obstetric problems. No relationships between maternal consumption of coffee and maternal serum lipid levels were observed. However, serum total cholesterol and LDL-cholesterol levels in infants'umbilical cord were significantly increased in proportion to increasing maternal consumption of coffee. The other factors such as alcohol drinking habits and residency affected maternal serum lipid levels and not serum lipid levels in infants' umbilical cord. Delivery frequency showed very little or no effects on serum lipid levels in both maternal blood and infant's umbilical cord blood. In conclusion, maternal consumption of coffee significantly correlated with increasement of serum lipid levels in infants'umbilical cord.

  • PDF

Totally Umbilical Slant Lightlike Submanifolds of Indefinite Kaehler Manifolds

  • Sachdeva, Rashmi;Kumar, Rakesh;Bhatia, Satvinder Singh
    • Kyungpook Mathematical Journal
    • /
    • v.57 no.3
    • /
    • pp.503-516
    • /
    • 2017
  • In this paper, we study totally umbilical slant lightlike submanifolds of indefinite Kaehler manifolds. We prove that there do not exist totally umbilical proper slant lightlike submanifolds in indefinite Kaehler manifolds other than totally geodesic proper slant lightlike submanifolds. We also prove that there do not exist totally umbilical proper slant lightlike submanifolds of indefinite Kaehler space forms. Finally, we give a characterization theorem on minimal slant lightlike submanifolds.

Relation between Folate Levels of Maternal-Umbilical Cord Blood, Placenta Tissue and Pregnancy Outcomes

  • Ahn, Hong Seok
    • Journal of Community Nutrition
    • /
    • v.6 no.2
    • /
    • pp.91-96
    • /
    • 2004
  • The purpose of this study was to evaluate the folate nutritional status of Korean pregnant women and to investigate the relation between folate levels of maternal-umbilical cord blood, placenta tissue, and pregnancy outcomes. The study subjects consisted of 25 pregnant women who have had normal term deliveries. Dietary folate intakes of the pregnants were estimated by semi quantitative frequency questionnaire and the serum and placenta tissue folate level was measured by microbiological analysis. The total folate intakes of the pregnant women was 655.6 ${\mu}$g/d, which was 131.1% of the Korean RDA for pregnants. Maternal serum folate level was 16.18ng/ml, which was significantly lower than that of umbilical cord blood (34.98ng/ml, p<0.05). Mean folate concentration of the placental tissue was 998.0ng/ml, which was the highest compared to maternal and umbilical cord serum level. Umbilical cord serum folate level and placental tissue folate level were highly influenced by maternal serum folate level. The umbilical cord folate levels of the infant group whose birth weight was higher than 3500g were significantly higher than the group whose birth weight was less than 3500g (p<0.05). The placental folate level was significantly higher in maternal group who showed desirable weight gain during pregnancy (11 - 14kg). In conclusion, the birth weigt was related to the umbilical cord folate level and the maternal weight gain was affected by the placental folate level.

Serum Folate Levels of Maternal-Umbilical Cord Blood and Pregnancy Outcomes (임신말 모체 및 제대 혈청의 엽산 농도와 임심결과)

  • 안홍석;김지선;이금주;김영태
    • Journal of Nutrition and Health
    • /
    • v.33 no.8
    • /
    • pp.840-847
    • /
    • 2000
  • This study was out to evaluate the folate nutritional status of Korean pregnant women and to investigate the relationship between serum folate levels of maternal-umbilical cord blood and pregnancy outcomes. Folate intakes of the pregnants was estimated by dietary folate intakes obtained from semiquantitative frequency questionnaire and supplementary folate intakes. The serum folate levels in both maternal blood and umbilical cord of 29 pregnant women at delivery and 13 nonpregnant controls were measured by redioimmunoassay. The total folate intakes(dietary and supplementary)of the pregnant women was 465. 4$\mu\textrm{g}$/d which was 93% of the Korean RDA for folate. Maternal mean serum folate levels of the pregnants was 6.1$\mu\textrm{g}$/ml, significantly lower than that of nonpregnant women(8.9ng/ml). Mean serumfolate level of umbilical cord blood was 14.2ng/ml, which was 2.3 folds higher than that of maternal blood. This finding indicates that the uptake of folate in the fetus may be due to an active placental transport mechanism. Maternal serum folate level correlated positively with that of umbilical cord blood, showing that folate concentration of umbilical cord blood is affected by maternal status. There was no significant correlation between the serum folate levels in maternal-umbilical cord blood and the pregnancy outcomes.(Korean J Nutrition 33(8) : 840-847, 2000)

  • PDF

A Study on Realization of Wireless Umbilical Device for Missile Systems (유도무기체계의 무선배꼽장치 구현연구)

  • Eun, Heehyun;Jung, Sukjong;Jung, Jaewon;Ro, Donggyu;Kang, Cheewoo;Park, Youngsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.813-821
    • /
    • 2017
  • This paper presents the study result on a realization of wireless umbilical device for missile systems. In general, a missile system is connected to a fire control equipment via an umbilical connector to get the electrical power for its internal equipment and communicate with each other. And these connectors inherently have many problems of mis-contact between pin and socket, and mis-separation during missile firing, etc. A wireless umbilical device using LC resonance is devised to solve these problems of the current technology. For hundreds of watts power transmission under the missile system environment of restricted space, we designed and made a prototype of wireless umbilical device. And we tested this wireless umbilical device with an aluminum cylinder having cutout windows which simulate missiles. We realized that the wireless technology can be used as a substitute for the conventional umbilical connectors, and EMI and environment tests should be followed further.

Application of Umbilical System for Launch Vehicle (우주 발사체 엄빌리칼 시스템의 현황 및 적용사례)

  • Kim, Dae Rae;Lim, Chankyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.21-25
    • /
    • 2017
  • The umbilical system used for launch vehicle is to connect all ground supply lines (Pneumatic, hydraulic and electrical) to launch vehicle and disconnect those at few second before launch vehicle lift-off (or simultaneously with launch vehicle lift-off). During launch preparation stage, all umbilical shall be securely connected and also at separation stage, separation of all umbilical line shall be guaranteed. Therefore finding an appropriate connection force is a key factor on development of umbilical system. According to these design requirement, various kind of umbilical system has been developed from early stage of space development till today. In this paper, various kind of umbilical system developed so far is introduced according to its feature and operational concept. Also, umbilical system used for KSLV-II is introduced

  • PDF

Coffee Consumption During Pregnancy in Korean and Effect upon Serum Lipids Level in Maternal and Umbilical Cord Blood (우리나라 여성의 임신 중 커피 음용 실태와 산모혈 및 제대혈 중 지질치 변화에 미치는 영향)

  • Oh, Seung-Min;Chung, Kyu-Hyuck
    • YAKHAK HOEJI
    • /
    • v.42 no.4
    • /
    • pp.459-466
    • /
    • 1998
  • To investigate the effect of coffee consumption during pregnancy on serum lipids in maternal and infants` umbilical cord blood, 76 cases of newborn infants and women delivered o f a child who had delivered at hospital located in Chung-Ju city from Feb. 1, 1996 to Aug. 31, 1996 were studied. The gestational ages of cases were 37 to 42 weeks and the average maternal ages were $28.3{\pm}4.63$ years old without any other medical or obstetric problems. Infants` Apgar scores and birth weights were decreased by above 3 cups per day of coffee consumption during pregnancy. No relationships between coffee consumption during pregnancy and maternal serum lipid levels were observed. However, serum total cholesterol and LDL-cholesterol levels in infants` umbilical cord were significantly increased with increasing coffee consumption during pregnancy. In contrary to coffee consumption, alcohol drinking habits affected maternal serum lipid levels but not serum lipid levels in infants` umbilical cord blood. Coffee consumption during pregnancy increased caffeine concentration in infants` umbilical cord blood. These results suggest that caffeine from maternal consumption of coffee can easily pass to the fetus and significantly affect serum lipids levels in infants` umbilical cord blood rather than those in maternal blood.

  • PDF

A Case of Modified Umbilical Herniorraphy in Thoroughbred Foal (더러브렛 망아지에서 제허니아 정복술 치료예)

  • 양영진;조길재;양재혁;남치주
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.239-242
    • /
    • 2002
  • A two-month-old female Thoroughbred foal was referred to the Equine Hospital, Jeju Stud Fm, Korea Racing Association. The foal was presented with opening of the abdominal ring by congenital predisposition. In physical examination, the foal revealed a mild heating, fluctuant swelling at umbilicus. The umbilical hernia was diagnosed, and then modified umbilical herniorraphy was performed and resulted in successful treatment. We conclude this method is of great value within the six-month-old foal with hernial ring size less than 10 cm.