• Title/Summary/Keyword: Ultrasonic Table

검색결과 20건 처리시간 0.027초

초음파 테이블을 이용한 단결정 사파이어 웨이퍼의 ELID 연삭가공 특성 연구 (A Study on the ELID Grinding Properties of Single Crystal Sapphire Wafer using Ultrasonic Table)

  • 황진하;곽태수;이득우;정명원;이상민
    • 한국기계가공학회지
    • /
    • 제12권4호
    • /
    • pp.75-80
    • /
    • 2013
  • Single crystal sapphire being used in high technology industry is a brittle material with a high hardness and excellent physical properties. ELID(Electrolytic In-Process Dressing) grinding technology was applied to material removal machining process of single crystal sapphire wafer. Ultrasonic vibration which added to material using ultrasonic table was adopted to efficient ELID grinding of sapphire materials. The evaluation of the ground surface of single crystal sapphire wafer was carried out by means of surface measuring by using AFM(Atomic Force Microscope), surface roughness tester and optical microscope device. As the results of experiment, it was shown that more efficient grinding was conducted when using ultrasonic table. In case of using #170 grinding wheel, surface roughness of ELID ground specimen in using ultrasonic table was superior to ELID ground specimen without ultrasonic table. However, In case of using #2000 grinding wheel, surface roughness of ELID ground specimen in using ultrasonic table was inferior to ELID ground specimen without ultrasonic table.

초음파 진동 테이블이 질화알루미늄 세라믹의 ELID 연삭 가공에 미치는 영향 (The Effect of Ultrasonic Vibration Table on ELID Grinding Process of Aluminum Nitride Ceramics)

  • 곽태수;정명원;김건희;곽인실
    • 한국정밀공학회지
    • /
    • 제30권12호
    • /
    • pp.1237-1243
    • /
    • 2013
  • This study has focused on the effect of ultrasonic vibration table in ELID grinding process of aluminum nitride ceramics. Aluminum nitride ceramics has superior physical and chemical properties and widely used in IC, LSI substrate, package and so on. To achieve the high effective machining of brittle and high strength ceramics as like aluminum nitride, machining method combined ELID grinding and ultrasonic vibration has been adopted in this study. From the experimental results, material removal rate, MRR has been increased maximum 36 percent and spindle resistance has been decreased in using ultrasonic table. Surface roughness of ground surface became a little worse in using ultrasonic table but was somewhat improved in feed direction.

불연속부의 위치를 고려한 초음파비파괴검사 등급보정 (Level Calibration of Ultrasonic Nondestructive Testing Considering Flaw Position)

  • 신병철;송호산;정화영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권4호
    • /
    • pp.155-160
    • /
    • 2001
  • KS-code(KS B 0896) for nondestructive ultrasonic testing classifies the quality level by relative flaw size only. But flaw position is more important than the flaw size. Test blocks having artificial holes near surface show lower yield load than the blocks having deeply located holes from the surface. So, level calibration table was proposed for classifying the quality level of welded steel structures.

  • PDF

Al6061의 엔드밀 절삭가공에서 초음파 진동이 가공 표면에 미치는 영향 (Effects of Ultrasonic Vibration on Machined Surface of Aluminium 6061 in Endmill Cutting Process)

  • 정명원;곽태수;김명규;김건희
    • 한국기계가공학회지
    • /
    • 제13권3호
    • /
    • pp.96-102
    • /
    • 2014
  • This study focused on the effects of ultrasonic vibration on a machined surface of Al6061 material in the endmill cutting process. It is known that ultrasonic vibration greatly increases the efficiency of the machining process when cutting or grinding. An ultrasonic vibration table was developed for application to ultrasonic vibration endmill machining experiments.Inthisstudy,the surface roughness and actual depth of the cut measured confirm the effects of ultrasonic vibration. As a result of the experiments, the actual depth of the cut increased during endmill machining when using ultrasonic vibration. The surface roughness was improved with increases in the amplitude of the vibration and the depth of the cut.

MLCC 적층용 진공척의 자기연마와 ELID연삭을 이용한 미세버 제거 기술 (Deburring Technology of Vacuum Plate for MLCC Lamination Using Magnetic Abrasive Polishing and ELID Process)

  • 이용철;신건휘;곽태수
    • 한국기계가공학회지
    • /
    • 제14권3호
    • /
    • pp.149-154
    • /
    • 2015
  • This study has focused on the deburring technology of a vacuum plate for MLCC lamination using electrolytic in-process dressing (ELID) grinding, and the magnetic-assisted polishing (MAP) process. The surface of the vacuum plate has many micro-holes for vacuum suction. They are easily blocked by the burrs created in the surface-flattening process, such as the conventional grinding process. In this study, the MAP process, the ELID grinding process, and an ultrasonic vibration table are examined to remove the micro-burrs that lead to the blockage of the holes. In the results of the experiments, the MAP process and ELID grinding technology showed significant improvements of surface roughness and deburring performance.

Measurement Uncertainties for Vacuum Standards from a Low to an Ultra-high Vacuum

  • Hong, S.S.;Shin, Y.H.;Lim, J.Y.
    • Applied Science and Convergence Technology
    • /
    • 제23권3호
    • /
    • pp.103-112
    • /
    • 2014
  • The Korea Research Institute of Standards and Science (KRISS) has three major vacuum systems: an ultrasonic interferometer manometer (UIM; Section II, Figs. 1 and 2) for a low vacuum, a static expansion system (SES; Section III, Figs. 3 and 4) for a medium vacuum, and an orifice-type dynamic expansion system (DES, Section IV, Figs. 5 and 6) for high and ultra-high vacuum systems. For each system, explicit measurement model equations with multiple variables are given. According to ISO standards, all of these system variable errors were used to calculate the expanded uncertainty (U). For each system, the expanded uncertainties (k = 1, confidence level = 95%) and relative expanded uncertainty (expanded uncertainty/generated pressure) levels are summarized in Table 4. Within the uncertainty limits, our bilateral and key comparisons [CCM.P-K4 (10 Pa to 1 kPa)] are extensive and in good agreement with those of other nations (Fig. 8 and Table 5).

Ultrasonic Instrumentation이 근관충전에 미치는 영향에 관한 연구 (AN EXPERIMENTAL STUDY ON THE EFFECT OF ULTRASONIC INSTRUMENTATION ON THE ROOT CANAL OBTURATION)

  • 허수범;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.181-189
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of apical seal produced by ultrasonic instrumentation. 120 extracted, permanent single rooted teeth were randomly divided into 6 groups of 20 teeth and root canals were enlarged & obturated according to Table I. After canal obturation, the obturated teeth were immersed in 2.5 % Methylene blue for 72 hrs. at $37^{\circ}C$ incubator and longitudinally sectioned. The apical sealing ability was evaluated by measuring the degree of dye penetration into the canal. The results were as follows: 1. All groups showed varying depth of dye penetration. 2. There were no significant differences between Group I and N, Group II and V, Group III and VI. (P>0.05) 3. Regardless of obturation method, there were no significant differences between hand instrumented group and ultrasonic instrumented group.(P>0.05).

  • PDF

전자빔 용접 측정 시스템에 관한 연구 (A Study of the Measurements System in Electron Beam Welding)

  • 홍민성;김종민
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.258-263
    • /
    • 2005
  • Because of its high performance and accuracy, electron beam welding has an important role in industrial applications such as semi-conductor and LCD manufactures. Since its operation has been done in a vacuum room, it is very difficult to check out their weldability as well as the correct welding area of the specimen. In this study, a measurement system of the electron beam welding has been developed based on the 3-axis LVDT controlled table. In addition, the algorithm to tracking the welding line has been developed. Welded regions were measured by using an A-scan ultrasonic sensor only. Weldability of the aluminum specimen has been tested by newly developed measuring system. The results are compared with those by using an C-scan ultrasonic sensor, which show good agreements with each other.

  • PDF

Evaluation of the seismic performance of butt-fusion joint in large diameter polyethylene pipelines by full-scale shaking table test

  • Jianfeng Shi;Ying Feng;Yangji Tao;Weican Guo;Riwu Yao;Jinyang Zheng
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3342-3351
    • /
    • 2023
  • High-density polyethylene (HDPE) pipelines in nuclear power plants (NPPs) have to meet high requirements for seismic performance. HDPE pipes have been proved to have good seismic performance, but joints are the weak links in the pipelines, and pipeline failures usually initiate from the defects inside the joints. Limited data are available on the seismic performance of butt-fusion joints of HDPE pipelines in NPPs, especially in terms of defects changes inside the joints after earthquakes. In this paper, full-scale shaking table tests were performed on a test section of suspended HDPE pipelines in an NPP, which included straight pipes, elbows, and 10 butt-fusion joints. During the tests, the seismic load-induced strain of the joints was analyzed by strain gauges, and it was much smaller than the internal pressure and self-weight-induced strain. Before and after the shaking table tests, phased array ultrasonic testing (PA-UT) was conducted to detect defects inside the joints. The locations, numbers, and dimensions of the defects were analyzed. It was found that defects were more likely to occur in elbows joints. No new defect was observed after the shaking table tests, and the defects showed no significant growth, indicating the satisfactory seismic performance of the butt-fusion joints.