• Title/Summary/Keyword: Thermometer

Search Result 355, Processing Time 0.053 seconds

Design and Implement of 50MHz 10 bits DAC based on double step Thermometer Code (50MHz 2단 온도계 디코더 방식을 사용한 10 bit DAC 설계)

  • Jung, Jun-Hee;Kim, Young-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.6
    • /
    • pp.18-24
    • /
    • 2012
  • This paper reports the test results of a 50MHz/s 10 bits DAC developed with $0.18{\mu}m$ CMOS process for the wireless sensor network application. The 10bits DAC, not likely a typical segmented type, has been designed as a current driving type with double step thermometer decoding architecture in which 10bits are divided into 6bits of MSB and 4bits of LSB. MSB 6bits are converted into 3 bits row thermal codes and 3 bits column thermal codes to control high current cells, and LSB 4 bits are also converted into thermal codes to control the lower current cells. The high and the lower current cells use the same cell size while a bias circuit has been designed to make the amount of lower unit current become 1/16 of high unit current. All thermal codes are synchronized with output latches to prevent glitches on the output signals. The test results show that the DAC consumes 4.3mA DC current with 3.3V DC supply for 2.2Vpp output at 50MHz clock. The linearity characteristics of DAC are the maximum SFDR of 62.02dB, maximum DNL of 0.37 LSB, and maximum INL of 0.67 LSB.

에코콘 탐사시스템을 이용한 지반특성 및 지반환경 조사

  • 정하익;김영진;홍승서;강동우;이경국
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.67-70
    • /
    • 2004
  • The purpose of this study is to develop the investigation technology of ground characteristics and environments using eco cone penetration system. The underground environments of landfill was investigated and analyzed by this eco cone system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in eco cone penetration system. This eco cone penetration system provides a continuous profile of measurements in underground, and provides repeatable, reliable and cost effective results for investigation of clean and contaminated ground.

  • PDF

Geo-Environmental Site Investigation for Underground Oil Storage facilities and Landfill Using the Envi-Cone Penetrometer System (환경콘 관입시스템을 이용한 유류저장소 및 폐기물매립지 지중환경특성 조사)

  • 정하익;홍승서;김영진;홍성완;곽무영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.33-36
    • /
    • 2000
  • The purpose of this study investigated underground oil storage(USTs) and Landfill using the envi-cone penetrometer system. The electrical resistivity sensor, pH sensor, ORP sensor, and thermometer are installed in envi-cone penetrometer system. This envi-cone penetrometer system provides a continuous profile of measurements, and it is rapid, repeatable, reliable and cost effective for investigation of contaminated ground.

  • PDF

A Study on High Resolution Time to Digital Converter for All Digital PLL (디지털 PLL을 위한 높은 해상도를 갖는 시간-디지털 변환기의 연구)

  • Kim, Yong-Woo;Ahn, Tae-Won;Moon, Yong
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.587-588
    • /
    • 2008
  • Digital PLL을 위한 높은 해상도를 갖는 TDC(Time to Digital Converter)를 $0.18{\mu}m$ CMOS 공정으로 설계하였다. 2단 구조를 갖는 TDC를 제안하였고 이를 Cadence Spectre를 이용하여 검증하였다. TDC는 Difference pulse generator, coarse 변환기와 fine 변환기로 구성된다. 그리고, 2단 변환기와 Thermometer decoder를 이용하여 delay cell의 수를 적게 유지하면서도 높은 해상도를 얻을 수 있었다.

  • PDF

Estimating evapotranspiration using leaf temperatured (엽온도 측정을 통한 증발산량 산정(관개배수 \circled1))

  • 이훈선;이남호
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.151-156
    • /
    • 2000
  • This study was to evaluate the effect of leaf temperature on daily evapotranspiration of crop. A transpiring crop will be cooled by the vaporization of water to a temperature below that of the surrounding air. Leaf temperature was measured a infrared thermometer. Crop evapotranspiration was measured by the method of lysimeter. A statistical model for estimating evapotranspiration was developed and tested. It was showed that the model was applicable.

  • PDF

Low power 3rd order single loop 16bit 96kHz Sigma-delta ADC for mobile audio applications. (모바일 오디오용 저 전압 3 차 단일루프 16bit 96kHz 시그마 델타 ADC)

  • Kim, Hyung-Rae;Park, Sang-Hune;Jang, Young-Chan;Jung, Sun-Y;Kim, Ted;Park, Hong-June
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.777-780
    • /
    • 2005
  • 모바일 오디오 적용을 위한 저전력 ${\Sigma}{\Delta}$ Modulator 에 대한 설계와 layout 을 보였다. 전체 구조는 3 차 단일 피드백 루프이며, 해상도는 16bit 을 갖는다. 샘플링 주파수에 따른 Over-sampling Ratio 는 128(46kHz) 또는 64(96kHz) 가 되도록 하였다. 차동 구조를 사용한 3 차 ${\Sigma}{\Delta}$ modulator 내의 적분기에 사용된 Op-Amp 는 DC-Gain 을 높이기 위해서 Gain-boosting 기법이 적용되었다. ${\Sigma}{\Delta}$ modulator 의 기준 전압은 전류 모드 Band-Gap Reference 회로에서 공급이 되며, PVT(Process, Voltage, Temperature) 변화에 따른 기준 전압의 편차를 보정하기 위하여, binary 3bit 으로 선택하도록 하였다. DAC 에서 사용되는 단위 커패시터의 mismatch 에 의한 성능 감소를 막기 위해, DAC 신호의 경로를 임의적으로 바꿔주는 scrambler 회로를 이용하였다. 4bit Quantizer 내부의 비교기 회로는 고해상도를 갖도록 설계하였고, 16bit thermometer code 에서 4bit binary code 변환시 발생하는 에러를 줄이기 위해 thermometer-to-gray, gray-to-binary 인코딩 방법을 적용하였다. 0.18um CMOS standard logic 공정 내 thick oxide transistor(3.3V supply) 공정을 이용하였다. 입력 전압 범위는 2.2Vp-p,diff. 이며, Typical process, 3.3V supply, 50' C 시뮬레이션 조건에서 2Vpp,diff. 20kHz sine wave 를 입력으로 할 때 SNR 110dB, THD 는 -95dB 이상의 성능을 보였고, 전류 소모는 6.67mA 이다. 또한 전체 layout 크기는 가로 1100um, 세로 840um 이다.

  • PDF

Analysis and Improvement for Method of Boiling Point Measurement described in Middle School Science Textbooks (중학교 과학 교과서에 기술된 끓는점 측정 방법 분석 및 개선점 제안)

  • Noh, Eul;Jang, Nak Han
    • Journal of Science Education
    • /
    • v.39 no.3
    • /
    • pp.446-456
    • /
    • 2015
  • We have analyzed affecting factors of boiling point measurement and proposed to improve these after identifying errors of boiling point experiment in 7th grade science textbooks of 2009 revised curriculum. In the result of analyzing affecting factor of boiling point measurement for nine kinds of science textbooks, we have identified six affecting factors like as types of thermometer, heating instrument, sealing or not of stopper, position of thermometer, shape of container, and volume ratio of material and container. When performing experiment of boiling point measurement, we identified the best results when heating with a hot plate, positioning thermo sensor of MBL near neck branch after filling and sopping 10% volumes of material in round bottom flask. Based on this result, we have compared nine kinds of 7th grade science textbooks and found many errors that must be corrected in most of textbooks. Therefore it should be improved the experiment of science textbooks to enhance the understanding of students and to prevent from misconceptions for boiling point measurement.

  • PDF

An Analysis of Textbooks and an Investigation of Science Teacher's Views on 'Boiling Point' and 'Melting Point' (끊는점과 녹는점에 대한 교과서 내용 분석 및 과학교사들의 인식조사)

  • Kim, Seong-Su;Baek, Seong-Hui
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.3
    • /
    • pp.252-264
    • /
    • 2002
  • In this study, the experimental apparatus for boiling point and melting point in science textbooks of various curriculums were analyzed. Science teachers' views on the difference between the experimental value and the value written in textbooks were inquired, too. Their views on the experimental apparatus, nd results of freezing point,melting point, boiling point, fractional distillation, and thermometer calibration were also investigated. The results of this study showed that the types of experimental apparatus for boiling point and melting point were somewhat dif-ferent with science textbooks and curriculum. The teachers' views were also various according to their background. In the experiment of the fractional distillat ion, a large number of teachers recognized mismatch between the exper-imental value and the value written in textbooks as mistake of textbook contents or problem of experiment itself. The teachers of chemistry background take higher recognition of the requirement of thermometer calibration than those of non-chemistry background in middle school.

Output Noise Reduction Technique Based on Frequency Hopping in a DC-DC Converter for BLE Applications

  • Park, Ju-Hyun;Kim, Sung Jin;Lee, Joo Young;Park, Sang Hyeon;Lee, Ju Ri;Kim, Sang Yun;Kim, Hong Jin;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.371-378
    • /
    • 2015
  • In this paper, a different type of pulse width modulation (PWM) control scheme for a buck converter is introduced. The proposed buck converter uses PWM with frequency hopping and a low quiescent.current low dropout (LDO) voltage regulator with a power supply rejection ratio enhancer to reduce high spurs, harmonics and output voltage ripples. The low quiescent.current LDO voltage regulator is not described in this paper. A three-bit binary-to-thermometer decoder scheme and voltage ripple controller (VRC) is implemented to achieve low voltage ripple less than 3mV to increase the efficiency of the buck converter. An internal clock that is synchronized to the internal switching frequency is used to set the hopping rate. A center frequency of 2.5MHz was chosen because of the bluetooth low energy (BLE) application. This proposed DC-DC buck converter is available for low-current noise-sensitive loads such as BLE and radio frequency loads in portable communications devices. Thus, a high-efficiency and low-voltage ripple is required. This results in a less than 2% drop in the regulator's efficiency, and a less than 3mV voltage ripple, with -26 dBm peak spur reduction operating in the buck converter.

An Anxiety, Depressed Mood, and Insomnia in Newly Diagnosed Women Breast Cancer Patients and Thyroid Cancer Patients (처음 진단받은 여성 유방암 환자와 갑상선암 환자에서 나타나는 불안, 우울 및 불면 증상)

  • Park, So-Hyun;Choi, Hee-Yeon;Lim, Weon-Jeong;Moon, Byung-In;Lim, Woo-Sung
    • Korean Journal of Biological Psychiatry
    • /
    • v.24 no.4
    • /
    • pp.204-211
    • /
    • 2017
  • Objectives In this study, we identified the symptoms of insomnia, anxiety, and depressed mood in newly diagnosed women breast and thyroid cancer patients. Methods The subjects of this study were 1794 women patients who visited the Ewha Womans University Cancer Center for Women. They included 1119 newly diagnosed primary breast cancer patients and 675 newly diagnosed primary thyroid cancer patients. The patients completed the National Cancer Center Psychological Symptom Inventory (NCC-PSI) during their first follow-up visit after surgery, before starting chemotherapy or radiotherapy. The NCC-PSI is composed of the modified distress thermometer (MDT) and the modified impact thermometer (MIT) for insomnia, anxiety, and depressed mood. Results Anxiety severity was found to be greater in breast cancer patients than in thyroid cancer patients. Significant levels of anxiety, depressed mood and insomnia were present in 28, 24.5, and 20.7% in all the subjects, respectively. Moreover, anxiety symptoms, depressed mood and insomnia interfered with the daily lives of 20, 18.4, and 14.2% of all the subjects, respectively. Dealing with anxiety (18.8%) was found to need the most help, followed by dealing with insomnia (8.9%) and depressed mood (8.7%). Conclusions A significant level of distress was found in about 40% of the total subjects. Nearly 30% of newly diagnosed breast cancer patients reported significant anxiety symptoms and interferences with daily living caused by anxiety, which most commonly needed special care. Early assessment and management of psychological distress, especially anxiety, in breast and thyroid cancer treatment are very important to establish integrated cancer care.