• Title/Summary/Keyword: Tester

Search Result 2,186, Processing Time 0.033 seconds

A study on the tester design of Autonomous station control system (자율분산 역 제어시스템의 테스터 설계 연구)

  • Kim, Young-Hoon;Hong, Soon-Heum
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1531-1535
    • /
    • 2008
  • The Tester of Autonomous station control system is a system which can test the main function of Autonomous station control system through the data field. The purpose of this paper is to meet the system requirements and design a main function, menu and user interface using Use-case. The main function is a time-deadline test, a schedule broadcast test, a route control test and a version-up test, etc. The design of Autonomous station control system tester plays a primary role of the important document for the upcoming future system development of the tester.

  • PDF

Anti-wear performance and life evaluation of wheel bearing type greases

  • Kim Jung-Young;Chung Keun-Wo;Kim Young-Wun;Jo Won-Oh
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.111-116
    • /
    • 2004
  • Li-complex and urea type greases (each 10 species) which were furnished by Chang-Am LS, analyzed anti-wear performance into fretting wear tester & four-bail wear tester. from the results of fretting wear test, the wear volume of Li-complex greases are $4.6\~8.9mg\;and\;8.3\~14.4mg$ with the test of urea greases. The anti-wear performance for 4-ball wear test of greases produced results around 0.5mm at the value of WSD. The grease life performance were evaluated by SKF-ROF Grease Tester and wheel bearing life tester. From the results of SKF-ROF tester, the life performance evaluated by whole working time produced results $50\~300hr$ with the Li-complex greases and 100-1000hr with the urea greases. That is to say, in spite of severe condition at the higher of $10^{\circ}C$ reaction temp, the life performance with Urea type greases are much superior to Li-complex type greases. Prior to wheel bearing life tester, the grease selected performance evaluation(=anti-wear test) are tested by wheel bearing tester. In this results, we can confirm results those are similar with SKF-ROF tester. In this study, we can draw two major conclusions, one is that Li-complex greases are superior to urea greases with anti-wear properties and the other is that urea greases are much superior to Li-complex greases with life performance.

  • PDF

CTIS: Cross-platform Tester Interface Software for Memory Semiconductor (메모리 반도체 검사 장비 인터페이스를 위한 크로스플랫폼 소프트웨어 기술)

  • Kim, Dong Su;Kang, Dong Hyun;Lee, Eun Seok;Lee, Kyu Sung;Eom, Young Ik
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.10
    • /
    • pp.645-650
    • /
    • 2015
  • Tester Interface Software (TIS) provides all software functions that are necessary for a testing device to perform the test process on a memory semiconductor package from the time the device is put into the test equipment until the device is discharged from the equipment. TIS should perform the same work over all types of equipment regardless of their tester models. However, TIS has been developed and managed independently of the tester models because there are various equipment and computer models that are used in the test process. Therefore, more maintenance, time and cost are required for development, which adversely affects the quality of the software, and the problem becomes more serious when the new tester model is introduced. In this paper, we propose the Cross-platform Tester Interface Software (CTIS) framework, which can be integrated and operated on heterogeneous equipment and OSs.

Effect of Thermal Grease on Thermal Conductivity for Mild Steel and Stainless Steel by ASTM D5470 (ASTM D5470 방법으로 연강과 스테인리스강의 열전도도 측정시 열그리스의 영향)

  • Cho, Young-Wook;Hahn, Byung-Dong;Lee, Ju Ho;Park, Sung Hyuk;Baeg, Ju-Hwan;Cho, Young-Rae
    • Korean Journal of Materials Research
    • /
    • v.29 no.7
    • /
    • pp.443-450
    • /
    • 2019
  • Thermal management is a critical issue for the development of high-performance electronic devices. In this paper, thermal conductivity values of mild steel and stainless steel(STS) are measured by light flash analysis(LFA) and dynamic thermal interface material(DynTIM) Tester. The shapes of samples for thermal property measurement are disc type with a diameter of 12.6 mm. For samples with different thickness, the thermal diffusivity and thermal conductivity are measured by LFA. For identical samples, the thermal resistance($R_{th}$) and thermal conductivity are measured using a DynTIM Tester. The thermal conductivity of samples with different thicknesses, measured by LFA, show similar values in a range of 5 %. However, the thermal conductivity of samples measured by DynTIM Tester show widely scattered values according to the application of thermal grease. When we use the thermal grease to remove air gaps, the thermal conductivity of samples measured by DynTIM Tester is larger than that measured by LFA. But, when we did not use thermal grease, the thermal conductivity of samples measured by DynTIM Tester is smaller than that measured by LFA. For the DynTIM Tester results, we also find that the slope of the graph of thermal resistance vs. thickness is affected by the usage of thermal grease. From this, we are able to conclude that the wide scattering of thermal conductivity for samples measured with the DynTIM Tester is caused by the change of slope in the graph of thermal resistance-thickness.

Development of a Precision Friction Tester (미세마찰실험장치의 개발)

  • 김충현;안효석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.64-68
    • /
    • 2002
  • It is an object of this research to develop a fine friction tester capable of analyzing a friction characteristics of a small size specimens in a load range of 0.03 ∼ 2.0 N. According to the test results using the developed precision friction tester, it is expected to get the experimental data with fine resolution and high reliability.

  • PDF

Development of Live-line Insulator Tester and Its Application to 154kV Power Lines - Part 1 : Tester Development (활선애자점검기의 개발 및 154kV 선로에의 적용 - 제1부 : 점검기 개발)

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak;Oh, Ki-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.83-88
    • /
    • 2010
  • A new live-line insulator tester was developed to detect faulty insulators in 154kV power transmission lines. This paper is the first part of the two-part paper and deals with its tester development. The developed tester has the following characteristics. First, it automates parts of the insulator inspection process by using a sensor and an actuator, and secondly, it sustains its weight by itself, not by a lineman. Finally, it measures the insulation resistance of an insulator together with its distribution voltage to provide more information for its analysis and diagnosis. These leads to the improvement of its operation efficiency, measurement reliability and usability. Its effectiveness was validated by live-line field tests in actual power lines.

Development of Laser Diode Tester and Position Compensation using Feedback with Machine Vision (Laser Diode Tester 개발과 비젼 피드백을 이용한 위치 보정)

  • 김재희;유철우;박상민;유범상
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.30-36
    • /
    • 2004
  • The development of LD(Laser Diode) tester and its control system based on the graphical programming language(LabVIEW) is addressed. The ill tester is used to check the optic power and the optic spectrum of the LD Chip. The emitter size of LD chip and the diameter of the Detector(optic fiber and photo diode) are very small, therefore the test device needs high accuracy. But each motion part of the test device could not accomplish high accuracy due to the limit of the mechanical performance. So, an image processing with machine vision is proposed to compensate for the error. By adopting our method we can reduce the error of position within $\pm$5$\mu\textrm{m}$.

The development of CB Characteristic Tester for 25.8kV GIS (25.8kV GIS용 차단기 동작특성 시험장치 개발)

  • Lee, Bong-Hee;Park, Soon-Kyu;An, Young-Ho;Yoon, Kap-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.666-668
    • /
    • 2001
  • In this paper we are to explain the development of circuit breaker characteristic tester for 25.8kV Gas Insulated Switchgear. Because of hermetically sealed cubicle, we have the difficulties of installation and usage of tester. Therefore we developed measuring tester and software. This tester can measure CB close/trip time, coil current, stroke, chattering time. And it has CB positive/ negative discrimination program, trend management program, DB management program.

  • PDF

Effects of Flow Settling Means on the Performance of Fan Tester (유동안정화 장치가 홴 테스터의 성능에 미치는 영향)

  • Choi, Young-Seok;Kim, Deok-Su;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.5 s.32
    • /
    • pp.29-34
    • /
    • 2005
  • In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics (CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

Developement of Consolidation Cell of Horizontal Drainage using Standard Consolidation Tester (표준압밀시험기를 사용하는 수평배수 압밀셀의 개발)

  • Ju, Jae-Woo;Cheong, Gyu-Hyang;Cho, Sam-Deok;Lee, Chun-Ju;Park, Jong-Beom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.678-683
    • /
    • 2004
  • The most popular consolidation tester is a standard consolidatiion tester, which performs consolidation using the step load weight. However this apparatus is used to obtain only the vertical consolidation coefficient. Therefore the purpose of this study is to develope the horizontal consolidation cell for a horizaontal consolidation coefficient. Various size of tests have been peroformed to investigate the effect of scale effect. From the test results, it has turned out that this horizontal consolidation cell has a good function for a horizontal consolidation coefficient.

  • PDF