DOI QR코드

DOI QR Code

Effects of Flow Settling Means on the Performance of Fan Tester

유동안정화 장치가 홴 테스터의 성능에 미치는 영향

  • 최영석 (한국생산기술연구원) ;
  • 김덕수 (한양대학교 대학원, 한국생산기술연구원) ;
  • 윤준용 (한양대학교 기계공학부)
  • Published : 2005.10.01

Abstract

In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics (CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.

Keywords

References

  1. ANSI/AMCA 210-99, 1999, 'Laboratory Methods of Testing Fans for Aerodynamic Performance Rating'
  2. ISO 5801, 1997, 'Industrial fans-Performance testing using standardized airways'
  3. B. Sahin and A. J. Ward-Smith, 1987, 'The use of perforated plates to control the flow emerging from a wide-angle diffuser with application to electrostatic precipitator design,' Journal of Heat Fluid Flow, Vol. 8, pp. 124-131 https://doi.org/10.1016/0142-727X(87)90011-7
  4. E.M Laws and J. L. Livesey, 1978, 'Flow through screens,' Annual review of Fluid Mechanics, Vol. 10, pp. 247-266 https://doi.org/10.1146/annurev.fl.10.010178.001335
  5. B. Sahin, 1985, 'Flow control in a wideangle diffuser using perforated plates,' Ph. D. thesis, Department of Mechanical Engineering, Brunel University, London
  6. I.E. Idelchik, 1994, 'Handbook of hydraulic resistance'