Application Case of Test Construction of Hydro-Seeding Measures with Seed-Fertilizer-Soil Materials on the Slopes Along the National Road Between Munduk and Wubokgu (문덕우복구간 국도비탈면 종비토뿜어붙이기 시험시공 적용사례)

  • Jeon, Gi-Seong;Woo, Kyung-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.6
    • /
    • pp.130-138
    • /
    • 2007
  • To protect the surface of ground-cutting slopes occurring at the national road substitute detour [roundabout road]construction jobsite between Munduk and Wubokgu within the jurisdiction of Pohang-si and environment-friendly road construction, a test execution of re-vegetation measures on the major slopes was done and the results are as follows : As a result of finding out the number of sprouting individuals on the test construction site, the average number of sprouting individuals on the three test spots by the method of revegetation measures D, revegetation measures A, and revegetation measures B was 1,292 number of per square meter, 1,190 number of per square meter, and 1,095 number of per square meter respectively, which statistics were higher than those of test spot by the revegetation measures C. As a result of finding out living plant's breeding index [weight in dried state], the average dried weight of living plant at the test spot by the method of revegetation measures B, in case of foreign herbal species, was the highest marking 8.96 grams per square meter, and the next was 6.86grams per square meter by the method of revegetation measures D, and the next after was 6.80 grams per square meter by the method of revegetation measures A, and the last 5.93 grams per square meter by the method of revegetation measures C. As a result of finding out the covering degree on the slopes, the same average covering degree of 80% and 77.5% in revegetation measures A and revegetation measures D individually, which showed a somewhat higher covering degree than those of revegetation measures B and revegetation measures C. As a result of finding out appearing plants on the test construction site, seeding plant life was found to be sprouting on all test spot while native and foreign herbal species and herbaceous plant as well as shrubs were growing in good harmony with each other. However, in case of revegetation measures B and revegetation measures C method, foreign plant species are dominantly growing. As a result of inspecting rifts on the slopes and the excavated state by water, there existed cracks in some of base materials only in revegetation measures C method applied spot.

Modeling and verification of generator/control system of Seo-Inchon combined-cycle plant by load rejection test (부하차단시험에 의한 서인천복합화력 발전기.제어계의 모델링 및 검증)

  • 최경선;문영환;김동준;추진부;류승헌;권태원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.501-510
    • /
    • 1996
  • The gas-turbine generator of Seo-Incheon combined-cycle plant was tested for derivation of a model for dynamic analysis. Load rejection and AVR step test was performed to get the dynamic response of generator. The parameters of generator/control system model were determined by these measured data. No-load saturation test was performed for the saturation characteristics of the generator under steady state. V-curve test was also performed so as to find exact generator parameters. Q-axis parameters of generator was derived by measuring power angle. AVR and governor constants have been tuned by their oscillatory period and setting time characteristics. The derived parameters of generator control system is verified by one-machine infinite bus system simulation. (author). 7 refs., 20 figs., 5 tabs.

  • PDF

Comparison of tuberculin skin test with Interferon-γ assay for the diagnosis of bovine tuberculosis in Korean cattle (국내 우군에서 소 결핵 진단을 위한 피내검사법과 Interferon-γ 생성 검사의 비교)

  • Shin, Seung Won;Shin, Min Kyoung;Cha, Seung Bin;Woo, Jong Tae;Lee, Sung Mo;Ku, Bok Kyung;Cho, Yun Sang;Jung, Suk Chan;Yoo, Han Sang
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.2
    • /
    • pp.117-122
    • /
    • 2011
  • Bovine tuberculosis (bTB), caused primarily by Mycobacterium bovis, continues to exert an economic loss, even in countries with active control measures, and is one of zoonotic diseases enable to be transmitted to human. The control and eradication of bTB are mainly based on a test and slaughter policy and/or abattoir surveillance. Various factors including limitation of diagnostic tests have been considered as major constraints to eradication. Single intradermal test (SIT) is the official diagnostic test. New diagnostic methods are needed to be developed, because of limitations of the test. In the present study SIT was compared with single intradermal comparative cervical test (SICCT) and interferon (IFN)-${\gamma}$ assay. There was very low correlation between SIT and SICCT. However, high correlation was shown between SIT and IFN-${\gamma}$ assay while no correlation was observed between SICCT and IFN-${\gamma}$ assay. Therefore, our results suggest the possibility of replacement of SIT with IFN-${\gamma}$ assay for the diagnosis of bovine tuberculosis.

Natural Purification Treatment using Soil Brick with Combined Effective Microorganisms and Emergent Plants (복합유용미생물 및 수생식물을 활착시킨 흙블록을 이용한 자연정화 처리방법 연구)

  • Sim, Hagjae;Oh, Yongkeol;Park, Chulhwi;Kang, Wonsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.5
    • /
    • pp.543-550
    • /
    • 2015
  • In this study, using soil brick with combined effective microorganisms and emergent plants was identified which it can increase the effect of conservation and improvement of water. Lab-test was consist of four kind of reactors and each of reactors were A(rawwater), B(soil brick), C(emergent plant) and D(soil brick+emergent plant). Iris pseudoacorus, Phargmites australis, Typha angustifolia and Zizania latifolia were used for emergent plant. Evaluation of application on various environment were performed on agricultural waterway and pond. The pH measurement test of soil brick was performed due to evaluate whether a strong alkaline water flows out of the soil brick. Result of lab-test, removal efficiency of D was better than removal efficiency of A presenting 20.9%, 27.9% 21.5%, 33.8% and 58.4% for $COD_{Cr}$, $BOD_5$, TN, TP and TSS respectively. Removal efficiency of soil brick on agricultural waterway was revealed to be 49.5%, 45.0%, 43.7%, 37.3% and 28.6% for $COD_{Cr}$, $BOD_5$, TN, TP and TSS respectively. And removal efficiency of soil brick on the pond was revealed to be 12.7%, 10.5%, 9.32%, 10.4% and 36.3% for $COD_{Cr}$, $BOD_5$, TN, TP and TSS respectively. Result of pH measurement test of soil brick was neutral which was about 6 to 8.

Apparent digestibility coefficients of plant feed ingredients for olive flounder (Paralichthys olivaceus)

  • Mostafizur Rahman;Buddhi E. Gunathilaka;Sang-Guan You;Kang-Woong Kim;Sang-Min Lee
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.2
    • /
    • pp.87-96
    • /
    • 2023
  • This study was designed to determine the apparent digestibility coefficients of soybean meal, soy protein concentrate (SPC), soy protein isolate (SPI), rapeseed meal (RSM), pea protein concentrate (PPC), wheat gluten meal (WGM) and wheat flour (WF) for olive flounder, Paralichthys olivaceus. A reference diet (RF) was formulated to meet the nutrient requirements of olive flounder with 1% chromic oxide (Cr2O3) as an inert indicator. Test diets were prepared to contain 70% RF and 30% of the test ingredient. Olive flounder, averaging 150 ± 8.0 g, was cultured in 400-L fiberglass tanks at a density of 25 fish per tank. Fecal collection columns were attached to each tank. Fecal samples were obtained from triplicate groups of fish for 4 weeks. Dry matter digestibility of SPC (75%) and WGM (76%) were significantly higher than the other test ingredients. Protein digestibility of SPC (85%), PPC (88%) and WGM (89%) were significantly higher than the other test ingredients, and protein digestibility of RSM (77%) and WF (76%) was lower than the other ingredients tested. Lipid digestibility of SPC (72%) and SPI (69%) were significantly higher than the other test ingredients. Energy digestibility of SPC (85%) and WGM (82%) were significantly higher than that of others tested ingredients. The availability of amino acids in WGM was generally higher than in other plant-feed ingredients. Therefore, SPC and WGM were seems to be efficient as potential protein sources for olive flounder compared to other tested ingredients. Overall, findings of the current study may assist in more efficient and economical formulation of diets using plant feed ingredients for olive flounder.

Risk Assessment for Abolition of Gross Containment Leak Monitoring System Test in CANDU Design Plant (중수로 원자로건물 총누설감시계통 시험 중지에 따른 리스크 영향 평가)

  • Bae, Yeon-Kyoung;Na, Jang-Hwan;Bahng, Ki-In
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.5
    • /
    • pp.123-130
    • /
    • 2015
  • Wolsong Unit 2,3&4 has been performing a containment integrity test during power operation. This test could impact to the safe operation during test. If an accident occurs during pressure dropping phase, reactor trip can be delayed because of the increased pressure difference which causes a time delay to reach the trip set-point. On the contrary, if an accident occurs during pressure increasing phase, reactor trip could be accelerated because the pressure difference to the trip set-point decrease. Point Lepreau nuclear power plant, which installed GCLMS (Gross Containment Leakage Monitoring System) in 1990, has discontinued the test since 1992 due to these adverse effects. Therefore, we evaluated the risk to obviate the GCLMS test based on PWR's ILRT (Integrated Leak Rate Test) extension methodologies. The results demonstrate that risk increase rate is not high in case of performing only ILRT test at every 5 years instead of doing GCLMS test at every 1.5 years. In addition, the result shows that GCLMS test can be removed on a risk-informed perspective since risk increasement is in acceptable area of regulatory acceptance criteria.

Applied Cases and Application Technologies of Ultrasonic Nanocrystalline Surface Modification and Accelerated Fatigue Life Evaluation Using Ultrasonic Elastic Vibrational Energy (초음파탄성진동에너지를 이용한 표면개질처리 및 가속피로수명평가 기술의 적용사례 및 응용기술)

  • Jo, In-Sik;Jo, In-Ho;Oh, Joo-Yeon;Lee, Chang-Soon;Pyoun, Young-Sik;Park, In-Gyu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.115-121
    • /
    • 2013
  • It is greatly expected that the technologies of durability enhancement and evaluation for the core structures of plant facilities, marine plant and bridge constructures will be greatly expanded in the plant industry fields. In this study, the actively ongoing applied cases were tried to be analyzed in the present domestic industry fields through the Ultrasonic Nanocrystalline Surface Modification (UNSM) and Ultrasonic Fatigue Test (UFT) technologies using ultrasonic elastic vibrational energy, and the new application technology to improve the durability of plant industry field, especially plant facilities, marine plant and core weld components of bridge constructures will be presented.

Functional Test of A Station of Control System for Power Plant (발전소 제어시스템 기본 스테이션 기능 검증)

  • Byun, Seung-Hyun;Park, Doo-Yong;Lim, Ick-Hun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.25-32
    • /
    • 2011
  • A control system has been developed by korean engineers for 500MW korean standard type fossil power plant with the advent of retrofit of old control system. The developed control system is required to verify in terms of function and reliability prior to application to a power plant because a power plant is a very important facility in the industry. It is difficult to secure the enough period for installing the control system and commissioning due to the gradual increase of power demand and competitive power market environment. It is essential to verify the control system in order to reduce trial and error cases during overhaul period for application of control system to the power plant. This paper shows the case study of a functional test of a station of control system for power plant.

Bioassays of Plant Hormones and Plant Growth Regulating Substances II. Abscisic Acid and Brassinolide (식물홀몬 및 생장조절물질의 생물검정기술 II. Abscisic Acid 및 Brassinolide)

  • 최충돈
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.s01
    • /
    • pp.16-25
    • /
    • 1989
  • A bioassay is a test system using a living organism (in whole or in part) to determine the presence or relative potency of chemical substances. The development and uses of bioassay are intimately linked to the discovery and characterization of the major classes of plant hormones. An application of this relationship is helpful for understanding the concept of plant hormones as well as the use of bioassay. And plant bioassay have been development and employed not only for the discovery and characterization of the biological activity of plant growth regulators but also have served several important secondary roles. The ideal bioassay should possess the characteristic of high specificity. great sensitivity. short response time, low cost and ease of obtaining plant material. acceptable ease of manipulation, and minimal space and equipment requirements.

  • PDF

A Study on the Corrosion and Degradation of Boiler Tubes Steel in Fossil Power Plant

  • Baik, Young Min;Jeong, Hee Don;Kweon, Young Gak
    • Corrosion Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.123-128
    • /
    • 2006
  • It was analyzed the causes of boiler tube rupture due to a degradation and corrosion on the boiler tubes in fossil power plant. The experiments were carried out among samples taken from the operating facilities. The result were analyzed based on experimental results from mechanical strength, microstructure observation, and hardness measurement in order to determine the cause of local rupture on boiler tubes. In general, 2.25Cr-1Mo steel generates carbides, it is coarsened, its ductility and strength abruptly decreased as degradation is in progress, In order to confirm this phenomenon, we observed changes of the mount of Cr and Mo of carbide by carrying out EDX chemical composition analysis. The amount of Cr and Mo in the degraded material or service exposed material gradually increased the amount of Mo but initially they were almost maintained at the same amount. Furthermore, we observed that the carbide become coarsened both in the grain and at the grain boundary. Tensile test was carried out to measure a material hardness and to recognize a drop-off of hardness. Overall result for tensile strength and hardness turned out to be lower than new material and mechanical strength and hardness was degraded as the material degradation was in progress.