• Title/Summary/Keyword: TEM Journal

Search Result 3,012, Processing Time 0.031 seconds

The Antenna Radiating Pattern and Gain's changes according to Insulating Material (절연재에 따른 TEM 안테나의 방사패턴 및 이득 변화)

  • Lee, Ye-Na;Choi, Sun-Ho;Huh, Chang-Su;Choi, Jin-Su;Park, Woo-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.666-670
    • /
    • 2014
  • TEM Horn antenna is typically used in HPEM area. It is necessary to apply a high voltage of the antenna for radiating HPEM. Then, it is necessary to insulate essentially of applying a high voltage to the antenna. At this time, radiation pattern and gain of the TEM Antenna is changed. For this reason, it is necessary to analyze changing characteristics by using simulation. In this paper, I analyzed the radiation pattern of the antenna in accordance with the lens and insulating material. As a result, it was observed that the value of the gain is changed in accordance with the frequency. The lens is used for the antenna, the gain characteristic is improved.

Transmission Electron Microscopy Sample Preparation of Ge2Sb2Te5 Nanowire Using Electron Beam

  • Lee, Hee-Sun;Lee, Jun-Young;Yeo, Jong-Souk
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.199-202
    • /
    • 2015
  • A simple and novel transmission electron microscopy (TEM) sample preparation method for phase change nanowire is investigated. A $Ge_2Sb_2Te_5$ (GST) nanowire TEM sample was meticulously prepared using nanomanipulator and gas injection system in a field emission scanning electron microscopy for efficient and accurate TEM analysis. The process can minimize the damage during the TEM sample preparation of the nanowires, thus enabling the crystallographic analysis of as-grown GST nanowires without unexpected phase transition caused by e-beam heating.

Transmission Electron Microscopy Specimen Preparation for Layer-area Graphene by a Direct Transfer Method

  • Cho, Youngji;Yang, Jun-Mo;Lam, Do Van;Lee, Seung-Mo;Kim, Jae-Hyun;Han, Kwan-Young;Chang, Jiho
    • Applied Microscopy
    • /
    • v.44 no.4
    • /
    • pp.133-137
    • /
    • 2014
  • We suggest a facile transmission electron microscopy (TEM) specimen preparation method for the direct (polymer-free) transfer of layer-area graphene from Cu substrates to a TEM grid. The standard (polymer-based) method and direct transfer method were by TEM, high-resolution TEM, and energy dispersive X-ray spectroscopy (EDS). The folds and crystalline particles were formed in a graphene specimen by the standard method, while the graphene specimen by the direct method with a new etchant solution exhibited clean and full coverage of the graphene surface, which reduced several wet chemical steps and accompanying mechanical stresses and avoided formation of the oxide metal.

Theory of High Resolution TEM Image Formation: Coherence (2) (TEM 관련 이론해설(7): 투과전자현미경의 고분해능 영상이론: 결맞음 (2))

  • Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.36 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • In this review, the important ideas of coherence theory are introduced. The transfer function and damping envelopes of the microscope due to temporal and spatial coherence are described. The passbands and the condition of Scherzer focus are discussed in associated with the resolution of transmission electron microscope. The characterization of coherence is also described.

Transmission Electron Microscopy Specimen Preparation for Two Dimensional Material Using Electron Beam Induced Deposition of a Protective Layer in the Focused Ion Beam Method

  • An, Byeong-Seon;Shin, Yeon Ju;Ju, Jae-Seon;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • v.48 no.4
    • /
    • pp.122-125
    • /
    • 2018
  • The focused ion beam (FIB) method is widely used to prepare specimens for observation by transmission electron microscopy (TEM), which offers a wide variety of imaging and analytical techniques. TEM has played a significant role in material investigation. However, the FIB method induces amorphization due to bombardment with the high-energy gallium ($Ga^+$) ion beam. To solve this problem, electron beam induced deposition (EBID) is used to form a protective layer to prevent damage to the specimen surface. In this study, we introduce an optimized TEM specimen preparation procedure by comparing the EBID of carbon and tungsten as protective layers in FIB. The selection of appropriate EBID conditions for preparing specimens for TEM analysis is described in detail.

TEM sample preparation using micro-manipulator for in-situ MEMS experiment

  • Hyunjong Lee;Odongo Francis Ngome Okello;Gi-Yeop Kim;Kyung Song;Si-Young Choi
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.8.1-8.7
    • /
    • 2021
  • Growing demands for comprehending complicated nano-scale phenomena in atomic resolution has attracted in-situ transmission electron microscopy (TEM) techniques for understanding their dynamics. However, simple to safe TEM sample preparation for in-situ observation has been limited. Here, we suggested the optical microscopy based micro-manipulating system for transferring TEM samples. By adopting our manipulator system, several types of samples from nano-wires to plate-like thin samples were transferred on micro-electro mechanical systems (MEMS) chip in a single step. Furthermore, the control of electrostatic force between the sample and the probe tip is found to be a key role in transferring process.

Defects analysis of RE : YAG (RE = Nd3+, Er3+) single crystal synthesized by Czochralski method (Czochralski법으로 성장된 RE : YAG(RE = Nd3+, Er3+) 단결정의 결함분석)

  • Park, Cheong Ho;Joo, Young Jun;Kim, Hye Young;Shim, Jang Bo;Kim, Cheol Jin
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • RE : YAG ($RE=Nd^{3+}$, $Er^{3+}$) single crystals are laser diodes and generally grown by Czochralski method with controlling the various growth parameter. Since the defects occurred by temperature gradient or the rotation speed of solid-liquid growth interface act as the decline of crystal optical property during the growth procedure, crystalline quality improvement via defects analysis is necessary. The etch pit density (EPD) analysis was used to confirm the surface defect of grown RE : YAG single crystal and to select the area of transmission electron microscopy (TEM) analysis. Defects in the specimen produced by tripod polishing method such as buckling, rod shaped, bend contours by internal stress, segregation and others were observed by using 200 kV TEM and 300 kV FE-TEM.

Detection of CTX-M and TEM type extended-spectrum β-lactamases in Escherichia coli isolated from livestocks in Korea (국내 가축 유래 대장균에서 CTX-M 및 TEM형 extended-spectrum β-lactamases의 검출)

  • Cho, Jae-Keun;Sung, Myung-Suk;Kim, Jin-Hyun;Kim, Ki-Seuk
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.1
    • /
    • pp.37-43
    • /
    • 2011
  • This study was conducted to investigate the prevalence and genotypes of extended-spectrum ${\beta}$-lactamase (ESBL) in 377 Escherichia coli isolated from healthy and sick animals. Two isolates (0.5%), each of which were isolated from diseased swine and chicken, respectively, were confirmed as ESBL producing isolates by double disk synergy test, and showed a multidrug resistant phenotype. Minimum inhibitory concentration of cefotaxime for the two ESBL producing isolates were 3~4 times higher than those of ceftazidime, respectively. By PCR and sequencing, one isolate from swine have both $bla_{CTX-15}$ and $bla_{TEM-1}$, and one isolate from chicken have $bla_{CTX-15}$ and $bla_{TEM-116}$. Also, these genes were transferred to E. coli J53 by conjugation. These two isolates showed unrelated pulsed-field gel electrophoresis. To our knowledge, this is the first time that $bla_{TEM-116}$ gene was identified in E. coli isolated from animals in Korea. These results suggest more prudent use of third- generation cephalosporins, and surveillance and monitoring for ESBL producing E. coli in both animals and their environments should be necessary.

Change in Engine Exhaust Characteristics Due to Automotive Waste Heat Recovery (엔진 배기 폐열회수로 인한 배기 특성 변화)

  • Kim, Kibum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4723-4728
    • /
    • 2014
  • In this study, a thermoelectric module (TEM) and a diesel engine were modeled using 1-D commercial software AMESim, and the performance of the TEM was evaluated when the engine was operated under the NEDC driving cycle. The goal of TEM modeling was to investigate not only the waste heat recovery (WHR) rate and energy converting efficiency, but also the heat transfer rate by taking the materials characteristics into account. In addition, a diesel oxidation catalyst (DOC) was designed, and it was found that the waste heat recovery with TEM affects the activation of DOC and alters engine exhaust composition. The simulation indicated that the WHR using TEM is beneficial for decreasing the fuel consumption of vehicles, but the reduction in the exhaust temperature affects the activation of DOC, resulting in an approximately 14% increase in CO and HC emissions. Therefore, the effect of waste heat recovery on the automotive emission characteristics must be considered in the development of automotive engine WHR systems.

Characterization and Analysis of UWB Antennas in Time Domain (시간 영역에서의 초광대역 안테나 특성 해석)

  • Song Jong-Hwa;Park Young-Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.287-294
    • /
    • 2006
  • In the paper, characterization and analysis of UWB(Ultra Wide Band) antennas in time domain are described. The impulse propagation channel including UWB antennas is proposed for the analysis in time domain. Using the proposed propagation channel, the technique of obtaining impulse response of UWB antenna is proposed. Also, ringing, peak value of the impulse response, and the width of the impulse response are introduced as parameters for characterizing a UWB antenna in time domain. A modified UWB conical monopole antenna, a UWB TEM horn antenna, and a UWB stepped fat monopole antenna were fabricated. From the measurement of reflection coefficients, three antennas had bandwidth more than 3 GHz. The impulse responses of the antennas were measured in an anechoic chamber. The results showed that the TEM horn with highest gain has the highest peak amplitude and the stepped fat monopole antenna with narrowest bandwidth for reflection coeffcient had the widest width of the impulse response. Also, ringing in the stepped fat monopole antennas and the UWB conical monopole antenna were observed.