• 제목/요약/키워드: T-testing

검색결과 1,530건 처리시간 0.026초

원자력 발전소용 Tilting Check Valve의 특성실험 (II) (Characterisic Experiment of Tilting Check Valve for Nuclear Power Plant(II))

  • 염만오
    • 대한기계학회논문집B
    • /
    • 제22권6호
    • /
    • pp.803-812
    • /
    • 1998
  • In this study, testing equipment with which several kinds of valves can be tested was composed. Two kinds of tilting check valves and a swing check valve were tested to analyze their dynamic characteristics. The results of the experiment showed that the tilting check valves protected the pump but that the swing check valve could not protect the pump when the reverse flow rate was high. Also the dynamic equation of the tilting check valve was formulated and simulated using system characteristic constant t$_{c}$ and one method of predicting t$_{c}$ by comparing the results of the simulation with the results of the experiment was proposed.sed.

Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

  • Kim, No-Hyu;Lee, Sang-Soon
    • 비파괴검사학회지
    • /
    • 제23권6호
    • /
    • pp.577-582
    • /
    • 2003
  • This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process.

Fourier 변환 모아레 간섭에 의한 이차원적 변형률 해석 (Tow-dimensional Strain Analysis by Fourier Transform Moire Interferometry)

  • 박두원;도전 태조;삼본 길춘;한응교
    • 비파괴검사학회지
    • /
    • 제12권1호
    • /
    • pp.16-24
    • /
    • 1992
  • Moire interferometry using a diffraction grating and a laser is a powerful technique for analizing small deformation of a specimen. In the method, the x and y-directional fringe patterns are obtained by using the x and y-directional sets of two beams. If the both sets of two beams are simultaneously incident to the specimen, the x and y-directional fringe patterns are super imposed. In this case, it is difficult to separate each directional fringe pattern. Therefore each fringe pattern has been separately recorded by selecting each set of two beams. In order to analyze a two-dimensional strain changing with time, Moire interferometry using the two-dimensional fourier transform method is proposed and the x and y-directional fringes are separated. By this method, the thermal deformation of a glass plate is analyzed.

  • PDF

물/섬유강화 고분자 복합재료/물 경계면에서의 초음파 반사 (Ultrasonic Reflection at a Water/Fiber Reinforced Polymer Composite/Water Interface)

  • 이재학;이수철;전정남;오세종
    • 비파괴검사학회지
    • /
    • 제13권1호
    • /
    • pp.15-20
    • /
    • 1993
  • This study describes ultrasonic reflection at a water/fiber reinforced polymer composite/water interface. Theoretical predictions of reflected beam amplitudes are also presented. Four different polymer composite laminates are investigated : T300/5208 graphite/epoxy $[0]_{31T},\;[45/90/-45/0]_{3S},\;[45/-45]_{2S}$, and S-2 glass/epoxy $[0/90]_{4S}$. The analytical leaky plate wave dispersion curves for the unidirectional laminate and other three laminates can be obtained by searching for the minimum magnitude of the reflection coefficient.

  • PDF

방폭형 제전기의 개발 및 평가방법에 관한 연구 (A Study on the Development of an Electrostatic Eliminator and Evaluating Method of Explosion-Protection Construction)

  • 최상원
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.49-54
    • /
    • 2014
  • Electrostatic eliminators are essential in various areas of manufacturing industries to protect electrostatic hazards and to reduce inferior products. For ion sources used in the charge neutralizers, there are corona discharge, soft X-ray, and ultraviolet and glow discharge. Among them, corona discharge is generally used, because the corona discharge can easily and economically produce positive and negative ions including electrons in air at atmospheric pressure. But it is necessary to equip explosion-protection electrostatic eliminators wherever hazardous atmosphere. The electrostatic eliminators and their testing method of explosion-protection type have been developed in this research. The contents and scope of the research as follows; developing the type 'Ex s IIB T4' electrostatic eliminator of explosion-protection; developing the type 'Ex s d IIB T4' electrostatic eliminator of explosion-protection; developing the explosion-protection performance testing method of electrostatic eliminator for using AC power source.

변곡점을 이용한 신속한 압밀시험에 관한 연구 (Rapid Inflection Point Method of Consolidation Testing)

  • 민덕기;황광모;최규환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.681-688
    • /
    • 2000
  • This study presented the new method for evaluating the coefficient of consolidation by using inflection point method which was based on the fact that time factor, T corresponding to the inflection point of a semilogarithmic plot of a time curve is fixed and equals to T = 0.405 at 70% consolidation. In the proposed method, the next load increment is applied as soon as the necessary time required to identify the inflection point. Thus, the coefficient of consolidation may be easily evaluated. The time required to complete the testing using this rapid consolidation method could be as low as 1.5-3 hours compared with 1 or 2 weeks in the case of the conventional consolidation test.

  • PDF

System-On-a-Chip(SOC)에 대한 효율적인 테스트 데이터 압축 및 저전력 스캔 테스트 (Low Power Scan Testing and Test Data Compression for System-On-a-Chip)

  • 정준모;정정화
    • 대한전자공학회논문지SD
    • /
    • 제39권12호
    • /
    • pp.1045-1054
    • /
    • 2002
  • System-On-a-Chip(SOC)에 대하여 테스트 데이터 압축 및 저전력 스캔테스팅에 대한 새로운 알고리즘을 제안하였다. 스캔벡터내의 don't care 입력들을 저전력이 되도록 적절하게 값을 할당하였고 높은 압축율을 갖도록 적응적 인코딩을 적용하였다. 또한 스캔체인에 입력되는 동안 소모되는 scan-in 전력소모를 최소화하도록 스캔벡터의 입력 방향을 결정하였다. ISCAS 89 벤치마크 회로에 대하여 실험한 결과는 평균전력 소모는 약 12% 감소되었고 압축율은 약 60%가 향상됨을 보였다.

계장화 충격시험법에 의한 구조용강 용접부의 동적 파괴인성에 관한 연구 (A Study on the Dynamic Fracture Toughness of Welding Structural Steels by Instrumented Impact Testing)

  • 김헌주;김경민;윤의박
    • Journal of Welding and Joining
    • /
    • 제11권1호
    • /
    • pp.42-51
    • /
    • 1993
  • In this study, investigations were conducted in calculating parameters of elastic-plastic fracture mechanics using single specimen. The validity of these testing methods was judged by the confirmation of multiple specimen method of stop block test. The results were as follows: In order to measure a fracture toughness using the instrumented impact test, two general requirement must be considered; One, setting up proper impact velocity considered the effect of loading and the other, the necessity of low blow test for obtaining true energy by the compliance correction. It was possible to detect a crack initiation point by calculating the compliance changing rate from a load-defection curve. Criterion of a stable crack growth, $T_{mat}$ could be estimated by using key-curve method for a base metal. and combining Kaiser's rebound compliance with Paris-Hutchison's $T_{appl}$ equation for the brittled zone of welding heat affected.at affected.d.

  • PDF

평균과 비율 비교 (Hypothesis Testing: Means and Proportions)

  • 박선일;이영원
    • 한국임상수의학회지
    • /
    • 제26권5호
    • /
    • pp.401-407
    • /
    • 2009
  • In the previous article in this series we introduced the basic concepts for statistical analysis. The present review introduces hypothesis testing for continuous and categorical data for readers of the veterinary science literature. For the analysis of continuous data, we explained t-test to compare a single mean with a hypothesized value and the difference between two means from two independent samples or between two means arising from paired samples. When the data are categorical variables, the $x^2$ test for association and homogeneity, Fisher's exact test and Yates' continuity correction for small samples, and test for trend, in which at least one of the variables is ordinal is described, together with the worked examples. McNemar test for correlated proportions is also discussed. The topics covered may provide a basic understanding of different approaches for analyzing clinical data.

RAM의 최소 테스트 패턴에 관한 연구 (A Study on the Minimal Test Pattern of the RAM)

  • 김철운;정우성;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.23-25
    • /
    • 1996
  • In this paper aims at studying the minimal test pattem of the RAM. This also propose a scheme of testing faults from the new fault model using the LLB. The length of test patterns are 6N(1-wsf), 9.5N(2-wsf), 7N(3-wsfl, 3N(4-wsf) operations in N-bit RAM. This test techniques can write into memory cell the number of write operations is reduced and then much testing time is saved. A test set which detects all positive-negative static t-ws faults for t=0, 1, 2, 3, 4 and detects all pattern sensitive fault in memory array. A new fault model, which encompasses the existing fault model Is proposed.

  • PDF