Characterisic Experiment of Tilting Check Valve for Nuclear Power Plant(II)

원자력 발전소용 Tilting Check Valve의 특성실험 (II)

  • 염만오 (경남대학교 기계공학부)
  • Published : 1998.06.01

Abstract

In this study, testing equipment with which several kinds of valves can be tested was composed. Two kinds of tilting check valves and a swing check valve were tested to analyze their dynamic characteristics. The results of the experiment showed that the tilting check valves protected the pump but that the swing check valve could not protect the pump when the reverse flow rate was high. Also the dynamic equation of the tilting check valve was formulated and simulated using system characteristic constant t$_{c}$ and one method of predicting t$_{c}$ by comparing the results of the simulation with the results of the experiment was proposed.sed.

Keywords