• Title/Summary/Keyword: Swing Phase

Search Result 254, Processing Time 0.027 seconds

Single-Electron Logic Cells and SET/FET Hybrid Integrated Circuits

  • Kim, S.J.;Lee, C.K.;Lee, J.U.;Choi, S.J.;Hwang, J.H.;Lee, S.E.;Choi, J.B.;Park, K.S.;Lee, W.H.;Paik, I.B.;Kang, J.S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.1
    • /
    • pp.52-58
    • /
    • 2006
  • Single-electron transistor (SET)-based logic cells and SET/FET hybrid integrated circuits have been fabricated on SOI chips. The input-output voltage transfer characteristic of the SET-based complementary logic cell shows an inverting behavior where the output voltage gain is estimated to be about 1.2 at 4.2K. The SET/FET output driver, consisting of one SET and three FETs, yields a high voltage gain of 13 and power amplification with a wide-range output window for driving next circuit. Finally, the SET/FET literal gate for a multi-valued logic cell, comprising of an SET, an FET and a constant-current load, displays a periodic voltage output of high/low level multiple switching with a swing as high as 200mV. The multiple switching functionality of all the fabricated logic circuits could be enhanced by utilizing a side gate incorporated to each SET component to enable the phase control of Coulomb oscillations, which is one of the unique characteristics of the SET-based logic circuits.

Low-area Dual mode DC-DC Buck Converter with IC Protection Circuit (IC 보호회로를 갖는 저면적 Dual mode DC-DC Buck Converter)

  • Lee, Joo-Young
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.586-592
    • /
    • 2014
  • In this paper, high efficiency power management IC(PMIC) with DT-CMOS(Dynamic threshold voltage Complementary MOSFET) switching device is presented. PMIC is controlled PWM control method in order to have high power efficiency at high current level. The DT-CMOS switch with low on-resistance is designed to decrease conduction loss. The control parts in Buck converter, that is, PWM control circuit consist of a saw-tooth generator, a band-gap reference(BGR) circuit, an error amplifier, comparator circuit, compensation circuit, and control block. The saw-tooth generator is made to have 1.2MHz oscillation frequency and full range of output swing from supply voltage(3.3V) to ground. The comparator is designed with two stage OP amplifier. And the error amplifier has 70dB DC gain and $64^{\circ}$ phase margin. DC-DC converter, based on current mode PWM control circuits and low on-resistance switching device, achieved the high efficiency nearly 96% at 100mA output current. And Buck converter is designed along LDO in standby mode which fewer than 1mA for high efficiency. Also, this paper proposes two protection circuit in order to ensure the reliability.

Effect of Annealing Temperature on the Electrical Performance of SiZnSnO Thin Film Transistors Fabricated by Radio Frequency Magnetron Sputtering

  • Kim, Byoungkeun;Lee, Sang Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.1
    • /
    • pp.55-57
    • /
    • 2017
  • Amorphous oxide thin film transistors (TFTs) were fabricated with 0.5 wt% silicon doped zinc tin oxide (a-0.5SZTO) thin film deposited by radio frequency (RF) magnetron sputtering. In order to investigate the effect of annealing treatment on the electrical properties of TFTs, a-0.5SZTO thin films were annealed at three different temperatures ($300^{\circ}C$, $500^{\circ}C$, and $700^{\circ}C$ for 2 hours in a air atmosphere. The structural and electrical properties of a-0.5SZTO TFTs were measured using X-ray diffraction and a semiconductor analyzer. As annealing temperature increased from $300^{\circ}C$ to $500^{\circ}C$, no peak was observed. This provided crystalline properties indicating that the amorphous phase was observed up to $500^{\circ}C$. The electrical properties of a-0.5SZTO TFTs, such as the field effect mobility (${\mu}_{FE}$) of $24.31cm^2/Vs$, on current ($I_{ON}$) of $2.38{\times}10^{-4}A$, and subthreshold swing (S.S) of 0.59 V/decade improved with the thermal annealing treatment. This improvement was mainly due to the increased carrier concentration and decreased structural defects by rearranged atoms. However, when a-0.5SZTO TFTs were annealed at $700^{\circ}C$, a crystalline peak was observed. As a result, electrical properties degraded. ${\mu}_{FE}$ was $0.06cm^2/Vs$, $I_{ON}$ was $5.27{\times}10^{-7}A$, and S.S was 2.09 V/decade. This degradation of electrical properties was mainly due to increased interfacial and bulk trap densities of forming grain boundaries caused by the annealing treatment.

Characteristics of Schottky Barrier Thin Film Transistors (SB-TFTs) with PtSi Source/Drain on glass substrate

  • O, Jun-Seok;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.199-199
    • /
    • 2010
  • 최근 평판 디스플레이 산업의 발전에 따라 능동행렬 액정 표시 소자 (AMOLED : Active Matrix Organic Liquid Crystral Display) 가 차세대 디스플레이 분야에서 각광을 받고있다. 기존의 TFT-LCD에 사용되는 a-Si:H는 균일도가 좋지만 전기적인 스트레스에 의해 쉽게 열화되고 낮은 이동도는 갖는 단점이 있으며, ELA (Eximer Laser Annealing) 결정화 poly-Si은 전기적인 특성은 좋지만 uniformity가 떨어지는 단점을 가지고 있어서 AMOLED 및 대면적 디스플레이에 적용하기 어렵다. 따라서 a-Si:H TFT보다 좋은 전기적인 특성을 보이며 ELA 결정화 poly-Si TFT보다 좋은 uniformity를 갖는 SPC (Solid Phase Crystallization) poly-Si TFT가 주목을 받고있다. 본 연구에서는 차세대 디스플레이 적용을 위해서 glass 기판위에 증착된 a-Si을 SPC 로 결정화 시킨 후 TFT를 제작하고 평가하였다. 또한 TFT 형성시에 저온공정을 실현하기 위해서 소스/드레인 영역에 실리사이드를 형성시켰다. 소자 제작시의 최고온도는 $500^{\circ}C$ 이하에서 공정을 진행하는 저온 공정을 실현하였다. Glass 기판위에 a-Si이 80 nm 증착된 기판을 퍼니스에서 24시간 동안 N2 분위기로 약 $600^{\circ}C$ 에서 결정화를 진행하였다. 노광공정을 통하여 Active 영역을 형성시키고 E-beam evaporator를 이용하여 약 70 nm 의 Pt를 증착시킨 후, 소스와 드레인 영역의 실리사이드 형성은 N2 분위기에서 $450^{\circ}C$, $500^{\circ}C$, $550^{\circ}C$에서 열처리를 통하여 형성하였다. 게이트 절연막은 스퍼터링을 이용하여 SiO2를 약 15 nm 의 두께로 증착하였다. 게이트 전극의 형성을 위하여 E-beam evaporator 을 이용하여 약 150 nm 두께의 알루미늄을 증착하고 노광공정을 통하여 게이트 영역을 형성 후 에 $450^{\circ}C$, H2/N2 분위기에서 약 30분 동안 forming gas annealing (FGA)을 실시하였다. 제작된 소자는 실리사이드 형성 온도에 따라서 각각 다른 특성을 보였으며 $450^{\circ}C$에서 실리사이드를 형성시킨 소자는 on currnet와 SS (Subthreshold Swing)이 가장 낮은것을 확인하였다. $500^{\circ}C$$550^{\circ}C$에서 실리사이드를 형성시킨 소자는 거의 동일한 on current와 SS값을 나타냈다. 이로써 glass 기판위의 SB-TFT 제작 시 실리사이드 형성의 최적온도는 $500^{\circ}C$로 생각되어 진다. 위의 결과를 토대로 본 연구에서는 SPC 결정화 방법을 이용하여 SB-TFT를 성공적으로 제작 및 평가하였고, 차세대 디스플레이에 적용할 경우 우수한 특성이 기대된다.

  • PDF

The Effects of Muscle, Balance and Walking Training on Gait Kinematics in Children with Down Syndrome (근력, 평형성, 보행 동작훈련이 다운증후군 아동의 보행에 미치는 효과)

  • Lim, Bee-Oh;Kim, Kye-Wan;Yu, Yeon-Joo
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.1
    • /
    • pp.107-115
    • /
    • 2009
  • The purpose of this study were to investigate the effects of muscle, balance and walking training on muscle, balance and gait kinematics in children with Down syndrome. Nine children ($9{\sim}12$ years old) with Down syndrome participated in this study. The participant with Down syndrome participated in muscle, balance and walking training for 12 weeks, three times a week Kinematic variables of gait were measured 3-dimentional motion capture system. The results indicated that the pelvis rotation decreased, the knee and hip flexion increased, decreased leg sway during the swing phase, the cadence increased, and the stride length decreased after the muscle, balance and walking training. In conclusion, Down syndrome's gait kinematic variables improved after the muscle, balance and walking training.

Gait Type Change for Decrease of Leg's Fatness (다리의 지방감소를 위한 보행형태 변화에 관한 연구)

  • Bae, Sung-Soo;Lee, Hea-Deok;Oun, Jung-Young;Yoon, Chang-Goo;Choi, Houng-Sik
    • Journal of Korean Physical Therapy Science
    • /
    • v.4 no.1
    • /
    • pp.303-313
    • /
    • 1997
  • We developed the shoes which is specially designed to decrease the leg's fatness during walking and to improve the body figure. The analysis of the gait cycle and the shoes gave changes at the swing phase. We examined the results to 30 girl students of Yeong Dong Junior College for 5 weeks from 27, October to 29, Nobember in 1996, and the results were also obtained in decrease of their thigh's size in circumference. The results of the analysis are as followings; 1) After experiment circumference of the right thigh was decreased 0.04cm in noncontrol group and significantly decreased 1.04 cm in control group(p<0.01). 2) After experiment circumference of the left thigh was decreased 0.27 cm in noncontrol group and significantly decreased 1.17cm in control group(p<0.01). 3) After experiment circumference of the right calf of the leg decreased 0.09 cm in noncontrol group and significantly decreased 0.54 cm in control group(p<0.01). 4) After experiment circumference of the left calf of the leg decreased 0.21 cm in noncontrol group and significantly decreased 0.47 cm in control group. 5) After experiment body weight were not changed significantly in both group. In these results, if the people want to exercise the analysis of fat in the thigh, put on the shoes which improves the body figure and do daily work, and it will be naturally decreased the fat in thigh and they will maintain the beauty lines of the legs. There weren't any changes in the body weight while the fat of thigh in circumsference was analysed and decreased. It means that because the weight of the fat is very light, there weren't any changes in body weight.

  • PDF

A Study on a Algorithm of Gait Analysis and Step Count with Pressure Sensors (보행수 측정 및 보행패턴 분류 알고리즘)

  • Do, Ju-pyo;Choi, Dae-yeong;Kim, Dong-jun;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1810-1814
    • /
    • 2017
  • This paper develops an approach to the algorithm of Gait pattern Analysis and step measurement with Multi-Pressure Sensors. The process of gait consists of 8 steps including stance and swing phase. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. As 3 parts of foot is supporting most of human weight, multiple pressure sensors are attached on the parts of foot: forefoot, big toe, heel. normal gait proceed from heel, forefoot and big toe over time. While normal gait proceeds, values of heel, forefoot and big toe can be changed over time. So Each values of pressure sensors over time could discriminate whether it is normal or abnormal gait. Measuring Device consists of non-inverting amplifiers and low pass filter. Through timetable of values, normal gait pattern can be analyzed, because of supported weight of foot. Also, the peak value of pressure can judge whether it is walking or running. While people are running, insole of shoes is floating in the air on moment. Using this algorithm, gait analysis and step count can be measured.

Kinematic Analysis of The Rider Postural Alignments According to The Fitting of Stirrups Lengths during Horse Walk of High Level Rider (승마 평보 시 숙련자의 등자길이 피팅에 따른 기승자세정열의 운동학적 비교분석)

  • Ryew, Che-Cheong;Hyun, Seung-Hyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.329-338
    • /
    • 2014
  • The purpose of this study was to analyze of the rider postural alignments according to the fitting of stirrups lengths during walk of high level riders. Participants selected as subject were consisted of horse riders of high level (age: $47.66{\pm}3.51yrs$, height: $168.40{\pm}4.84cm$, body weight: $73.36{\pm}15.58kg$, low extremity length: $94.76{\pm}3.98cm$, career: $23.33{\pm}5.77yrs$) and walk with 3 types of stirrup lengths(ratio of low extremity 68.04%, 73.25%, 78.48%). The variables analyzed were consisted of the displacement of Y axis (center of mass, head, thigh, shank and foot), FR angle, LR angle, dynamic postural stability index (DPSI), coefficient of variation (CV%), and distance (X axis) of low extremity limb between right and left. The displacement of Y axis in COM, thigh, shank, foot limbs were not statistically significant, but movements of head showed greater distance of B type and C type than that of A type during 1 stride of walk. The FR and LR angle in trunk of horse rider, dynamic postural stability index and, coefficient of variation didn't show significant difference statistically according to the fitting of stirrup lengths. Also the distance (X axis) of low extremity in thigh and shank didn't show significant difference statistically in between right and left, but right and left foot showed greater distance in C type than that of B and A types during walk in horse back riding. The hip and ankle joint angle not statistically significant according to stirrups lengths, But knee joint angle showed more extended according to the increase of stirrups lengths during stance and swing phase in walk.

Application of Gait Analysis to the Patients with Cervical Myelopathy (경척수증 환자에 대한 보행분석의 적용)

  • Yoon, Sang Won;Rhim, Seung Chul;Roh, Sung Woo;Yu, Jong Youn;Ha, Sang Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.4
    • /
    • pp.528-535
    • /
    • 2000
  • Objective : To investigate objectively the postoperative improvement of gait disturbance in patients with cervical myelopathy through a gait analysis. Patients and Methods : Ten patients who underwent cervical decompression and fusion for cervical myelopathy caused by spondylosis, OPLL, or concomitant hypertrophy of ligamentum flavum were studied. Preoperatively, gait disturbance was present in all patients. The patients were evaluated by gait analysis using three dimensional motion analyzer to collect data of linear and kinematic parameters before surgery, 1 week and 3 months after surgery. Statistical analysis of the related pre-and post-operative data were performed. Results : In the linear parameters, average value of cadence, walking speed, stride length, step time, width and double support were increased postoperatively compare to preoperative value. In the kinematic parameters, average value of knee flexion during initial swing phase, plantar flexion of ankle and range of motion of hip joint were increased as well. These differences were statistically significant(p<0.05). Conclusion : This study suggests that gait analysis can be used as a method of quantitative analysis of postoperative gait improvement in patients with cervical myelopathy.

  • PDF

Effects of Changes in the Indoor and Outdoor Environmental on the Walking Speed and Lower Extremity Muscle Activities in People Aged Forty and Older than Seventy Years (실내·외 보행환경의 변화가 40대와 노인의 보행속도와 다리 근활성도에 미치는 영향)

  • Lee, Jun-Young;Kim, Tack-Hoon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.4
    • /
    • pp.139-148
    • /
    • 2018
  • PURPOSE: This study compared the effects of indoor and outdoor environmental changes on the activity of the major lower limb muscles and walking factors in people 40-50 years and those aged older than 70 years. METHODS: Ten middle-aged people in their forties (age:$44.2{\pm}2.7$, BMI:$21.8{\pm}1.8$) and 10 elderly aged more than 70 years (age:$76.4{\pm}5.9$, BMI:$22.2{\pm}1.9$) with a normal walking ability were included. The participants walked 100 m both indoors and outdoors at their own speed. Using a 3D motion analyzer and EMG, the walking speed, angle of the ankle and activity changes of the lower limb muscles were compared. RESULTS: Significant differences in walking speed and peak-plantar flexion angle were observed between the two groups (p<.05). The muscular activity of the gastrocnemius muscle (GCM) was significantly different outdoors in the swing phase between the two groups (p<.05). In the people aged in their forties, the muscular activity of the rectus femoris (RF) was significantly higher outdoors than indoors (p<.05). In the elderly, however, the muscular activity of the RF was lower outdoors than indoors (p<.05). When compared to those in there forties, the muscular activity of the outdoor RF significantly decreased in the elderly group (P<.05). The muscular activity of the biceps femoris (BF) in the elderly decreased significantly outdoors compared to indoors (p<.05). CONCLUSION: For the elderly, increasing the exposure to the new environments or focusing on the performance of repeated movements for gradual speed control and precise movements is required to maintain normal gaits and movements that are less affected by environmental changes.