• Title/Summary/Keyword: Surface Measurement

Search Result 5,000, Processing Time 0.036 seconds

Study on Non-contact Detection of Surface Cracks of the Metals Using an Open-Ended Coaxial Line Sensor at X-band (마이크로파 X-밴드에서의 종단 개방 동축선 센서를 이용한 금속표면균열의 비접촉 검출 연구)

  • Yang, Seung-Hwan;Kim, Dong-Seok;Kim, Ki-Bok;Kim, Jong-Heon;Kang, Jin-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.192-197
    • /
    • 2012
  • In this paper, a non-contact microwave technique was presented to detect the surface crack of the metals. An open-ended coaxial cable line was used as a sensor at 11 GHz, and the reflection coefficients were measured by scanning along the metal surface including artificial surface cracks. A parameter, the K value which was defined as the difference between maximum and minimum reflection coefficients, was measured and used to estimate the crack depth. A linear relationship between the K value and crack depth was found. This study showed that non-contact detection of the surface cracks of metals is possible using the open-ended coaxial line sensor at X-band.

Effects of the Free-Stream Turbulence and Surface Trip Wire on the Flow past a Sphere (자유류 난류와 표면 트립 와이어가 구 주위 유동에 미치는 영향)

  • Son, Kwang-Min;Choi, Jin;Jeon, Woo-Pyung;Choi, Hae-Cheon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.187-190
    • /
    • 2006
  • In the present study, effects of tree-stream turbulence and surface trip wire on the flow past a sphere at $Re\;=\;0.4\;{\times}\;10^5\;{\sim}\;2.8\;{\times}\;10^5$ are investigated through wind tunnel experiments. Various types of grids are installed upstream of the sphere in order to change the tree-stream turbulence intensity. In the case of surface trip wire, 0.5mm and 2mm trip wires are attached from $20^{\circ}\;{\sim}\;90^{\circ}$ at $10^{\circ}$ interval along the streamwise direction. To investigate the flow around a sphere, drag measurement using a load cell, surface-pressure measurement, surface visualization using oil-flow pattern and near-wall velocity measurement using an I-type hot-wire probe are conducted. In the variation of free-stream turbulence, the critical Reynolds number decreases and drag crisis occurs earlier with increasing turbulence intensity. With increasing Reynolds number, the laminar separation point moves downstream, but the reattachment point after laminar separation and the main separation point are fixed, resulting in constant drag coefficient at each free-stream turbulence intensity. At the supercritical regime, as Reynolds number is further increased, the separation bubble is regressed but the reattachment and the main separation points are fixed. In the case of surface trip wire directly disturbing the boundary layer flow, the critical Reynolds number decreases further with trip wire located more downstream. However, the drag coefficient after drag crisis remains constant irrespective of the trip location.

  • PDF

A study on the applicability of invisible environment of surface image velocimeter using far infrared camera (원적외선 카메라를 이용한 표면영상유속계의 비가시 환경 적용성 검토)

  • Bae, Inhyuk;Yu, Kwonkyu;Yoon, Byungman;Kim, Seojun
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.9
    • /
    • pp.597-607
    • /
    • 2017
  • In this study, the applicability of the surface image velocimeter using the far-infrared camera was examined in order to solve the application problem of the measurement in night time, which has been pointed out in previous studies as the limit of the surface image velocimeter. For this purpose, the accuracy evaluation of measurement of the far-infrared camera was conducted for two conditions. Accuracy was evaluated by calculating the relative error of the results of the measurements of surface image velocimeter using the normal video camera during the daytime that was already verified. As a result, the relative error of the surface velocimeter using the far infrared camera was 4.3% at maximum, the average error was about 1%, and the error of the fog condition was maximum 5.2% with an average of 2%. In conclusion, it is possible to measure with high accuracy when using far-infrared camera in a invisible environments where the water flow can not be visualized with a general camera.

Measurement of combustor surface temperature using phosphor thermometry (형광체를 이용한 연소기 표면온도 측정기술)

  • Kim, Yong-Gyoo;Lee, Seok Hwan;Kim, Sunghun;Yang, Inyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.228-231
    • /
    • 2017
  • The surface temperature of a combustor such as an aircraft engine is one of the important measuring factors related to the combustion performance. However, a conventional temperature measurement technique have a large measurement error due to a bad environment such as a combustion flame, vibration, and dust. In order to solve this problem, a technology has been developed which can measure the surface temperature of the combustor in real time using the wavelength change or attenuation time change according to the temperature of the phosphor. In this study, we developed a technique that can measure surface temperature of scram-jet combustor using phosphor thermometry. The calibration curve was obtained according to the temperature from $200^{\circ}C$ to $800^{\circ}C$ in the calibrated temperature chamber. So, we confirmed that phosphor thermometry can be used for measuring surface temperature of scram-jet combustor.

  • PDF

Measuring Technique For Acoustic Roughness of Rail Surface With Homogeneous Displacement Sensors (동일 변위센서를 사용한 레일표면 음향조도의 측정방법)

  • Jeong, Wootae;Jang, Seungho;Kho, Hyo-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7941-7948
    • /
    • 2015
  • Rolling noises during train operation are caused by vibration excited from irregularities of surface roughness between wheel and rail. Therefore, a proper measurement and analysis techniques of acoustic roughness between wheel and rail surface are required for transmission, prediction, and analysis of the train rolling noise. However, since current measuring devices and methods use trolley-based manual handling devices, the measurements induce unstable measuring speed and vibrational interface that increases errors and disturbances. In this paper, a new automatic rail surface exploring platform with a speed controller has been developed for improving measurement accuracy and reducing inconsistency of measurements. In addition, we propose a data integration method of the rail surface roughness with multiple homogeneous displacement sensors and verified the accuracy of the integrated data through standard test-bed railway track investigation.

Installation of Induced Current Measurement Systems in Substations and Analysis of GIC Data during Geomagnetic Storms

  • Choi, Kyu-Cheol;Park, Mi-Young;Ryu, Youngsoo;Hong, Youngsu;Yi, Jong-Hyuk;Park, Sung-Won;Kim, Jae-Hun
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.427-434
    • /
    • 2015
  • Coronal Mass Ejections (CME), which originate from active regions of the Sun's surface, e.g., sunspots, result in geomagnetic storms on Earth. The variation of the Earth's geomagnetic field during such storms induces surface currents that could cause breakdowns in electricity power grids. Hence, it is essential to both monitor Geomagnetically Induced Currents (GICs) in real time and analyze previous GIC data. In 2012, in order to monitor the variation of GICs, the Korean Space Weather Center (KSWC) installed an induced current measurement system at SINGAPYEONG Substation, which is equipped with 765 kV extra-high-voltage transformers. Furthermore, in 2014, two induced current measurement systems were installed on the 345 kV high-voltage transformers at the MIGEUM and SINPOCHEON substations. This paper reports the installation process of the induced current measurement systems at these three substations. Furthermore, it presents the results of both an analysis performed using GIC data measured at the SINGAPYEONG Substation during periods of geomagnetic storms from July 2013 through April 2015 and the comparison between the obtained GIC data and magnetic field variation (dH/dt) data measured at the Icheon geomagnetic observatory.

A Study on Estimation of Doppler Frequency in a Current Velocity Measurement Radar (유속 측정 레이다에서의 도플러 주파수 추정에 관한 연구)

  • Lee, Jonggil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1551-1557
    • /
    • 2013
  • A current velocity measurement radar estimates Doppler frequencies to extract the corresponding surface velocity information. Therefore, it is required to maintain the high degree of reliability and accuracy of Doppler frequency estimates. However, Doppler spectra of water surface return echoes can have very widely varying shapes according to measurement environments and weather conditions. Therefore, serious problems may arise in maintaining the reliability and accuracy of conventional velocity estimating algorithm in a radar sensor. Therefore, in this paper, a newly suggested algorithm is proposed for improvement using estimation of peak Doppler frequencies. The proposed method shows that the more accurate velocity measurement can be possible comparing with the conventional one.

A study for null lens design of autostigmatic type and the limitation of measurement accuracy for ultra precision manufacturing of large aspherical surface (대형 비구면의 초정밀 가공을 위한 자동무수차점 방식의 널 렌즈 설계 및 측정 정밀도의 한계에 관한 연구)

  • Kim, Kil-Seon;Rim, Cheon-Seog
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.71-78
    • /
    • 2005
  • A null lens system of autostigmatic type, consisting of two mirrors, is designed for testing a large aspherical mirror. The system is theoretically analyzed to determine the limitation of measurement accuracy according to the manufacturing and alignment errors. We confirmed that irregularity of the null lens surface is the principal factor among tolerances in limiting measurement accuracy. Consequently, we can predict that measurement accuracy will be from 5λ/100 to 4λ/1000 according to the amount of this irregularity. That is, we can present the limitation of possible measurement accuracy with actual alignment and manufacturing errors.

Point-diffraction interferometer for 3-D profile measurement of light scattering rough surfaces (광산란 거친표면의 고정밀 삼차원 형상 측정을 위한 점회절 간섭계)

  • 김병창;이호재;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.5
    • /
    • pp.504-508
    • /
    • 2003
  • We present a new point-diffraction interferometer, which has been devised for the three-dimensional profile measurement of light scattering rough surfaces. The interferometer system has multiple sources of two-point-diffraction and a CCD camera composed of an array of two-dimensional photodetectors. Each diffraction source is an independent two-point-diffraction interferometer made of a pair of single-mode optical fibers, which are housed in a ceramic ferrule to emit two spherical wave fronts by means of diffraction at their free ends. The two spherical wave fronts then interfere with each other and subsequently generate a unique fringe pattern on the test surface. A He-Ne source provides coherent light to the two fibers through a 2${\times}$l optical coupler, and one of the fibers is elongated by use of a piezoelectric tube to produce phase shifting. The xyz coordinates of the target surface are determined by fitting the measured phase data into a global model of multilateration. Measurement has been performed for the warpage inspection of chip scale packages (CSPs) that are tape-mounted on ball grid arrays (BGAs) and backside profile of a silicon wafer in the middle of integrated-circuit fabrication process. When a diagonal profile is measured across the wafer, the maximum discrepancy turns out to be 5.6 ${\mu}{\textrm}{m}$ with a standard deviation of 1.5 ${\mu}{\textrm}{m}$.

Surface Plasmon Resonance Ellipsometry Using an Air Injection System with an Extraction of Air System (공기주입 장치와 공기제거 장치를 사용한 표면 플라즈몬 공명 타원계측기)

  • Lee, Hong-Won;Cho, Eun-Kyoung;Jo, Jae-Heung;Won, Jong-Myoung;Shin, Gi-Ryang;CheGal, Won;Cho, Yong-Jai;Cho, Hyun-Mo
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.3
    • /
    • pp.182-188
    • /
    • 2009
  • The surface plasmon resonance ellipsometer (SPRE), using a multiple air injection system with an extraction of air system, has been proposed and developed to minimize measurement error of signals due to diffusion of reagent into running buffer. Since the diffusion of reagent into running buffer affects the refractive index of the running buffer by changing the concentration, characteristics of binding between various bio-molecules don't appear clearly in measurement results. The diffusion between running buffer and reagent can be blocked by using an air bubble injection system. An extraction of air system is used to remove the noise signal due to unnecessary air bubbles flowing in a channel. Reliability of measurement results has been improved by using the valve system.