DOI QR코드

DOI QR Code

Point-diffraction interferometer for 3-D profile measurement of light scattering rough surfaces

광산란 거친표면의 고정밀 삼차원 형상 측정을 위한 점회절 간섭계

  • 김병창 (한국과학기술원 기계공학과) ;
  • 이호재 (한국과학기술원 기계공학과) ;
  • 김승우 (한국과학기술원 기계공학과)
  • Published : 2003.10.01

Abstract

We present a new point-diffraction interferometer, which has been devised for the three-dimensional profile measurement of light scattering rough surfaces. The interferometer system has multiple sources of two-point-diffraction and a CCD camera composed of an array of two-dimensional photodetectors. Each diffraction source is an independent two-point-diffraction interferometer made of a pair of single-mode optical fibers, which are housed in a ceramic ferrule to emit two spherical wave fronts by means of diffraction at their free ends. The two spherical wave fronts then interfere with each other and subsequently generate a unique fringe pattern on the test surface. A He-Ne source provides coherent light to the two fibers through a 2${\times}$l optical coupler, and one of the fibers is elongated by use of a piezoelectric tube to produce phase shifting. The xyz coordinates of the target surface are determined by fitting the measured phase data into a global model of multilateration. Measurement has been performed for the warpage inspection of chip scale packages (CSPs) that are tape-mounted on ball grid arrays (BGAs) and backside profile of a silicon wafer in the middle of integrated-circuit fabrication process. When a diagonal profile is measured across the wafer, the maximum discrepancy turns out to be 5.6 ${\mu}{\textrm}{m}$ with a standard deviation of 1.5 ${\mu}{\textrm}{m}$.

최근 전자산업계에 새롭게 널리 생산되는 마이크로 전자부품들은 왜곡이 최소화된 정밀한 외관 형상을 갖도록 제조되고 관리되지만, 측정 대상의 표면이 가시광 영역에서 광산란되는 특징을 가짐으로 인해, 기존의 피죠나 마이켈슨 형태의 비교간섭법으로는 고정밀의 삼차원 형상측정이 용이하지 아니하였다. 본 논문에서는 광섬유를 이용한 새로운 개념의 점회절 간섭계를 제안하고, 이를 광산란 거친표면의 대표적인 제품인 칩패키지와 실리콘 웨이퍼의 삼차원 형상 측정에 적용하였다. 측정결과 66 mm 측정영역에서 측정 형상오차 PV(peak-to-valley value) 5.6 $\mu\textrm{m}$, 분산값($\sigma$) 1.5 $\mu\textrm{m}$를 획득함으로써 기존의 비교 간섭 측정법에 비해 더욱 향상된 측정 정밀도를 획득하였다.

Keywords

References

  1. Appl. Opt. v.19 no.11 Rough surface inter ferometry at 10.6 μm O.Kwon;J.Wyant;C.Hayslett https://doi.org/10.1364/AO.19.001862
  2. J. Electron. Packaging v.122 no.3 Warpage measurement on dieledtric rough surface of microelectronics devices by far infra red fizeau interferomery K.Verma;B.Han https://doi.org/10.1115/1.1286315
  3. Opt. Lett. v.21 no.3 Grating interferometer for flatness testing P.J.de Groot https://doi.org/10.1364/OL.21.000228
  4. Appl. Opt. v.23 Tow-wavelength phase shifri interferometry Y.Y.Cheng;J.Wyant https://doi.org/10.1364/AO.23.004539
  5. Appl. Opt. v.29 The mirau correlation microscope G.Kino;S.Chim https://doi.org/10.1364/AO.29.003775
  6. Appl. Opt. v.26 Interferometric laser rangefinder using frequency modulated diode laser A.J.den Boef https://doi.org/10.1364/AO.26.004545
  7. Meas. Sci. Technol. v.9 The first measurement of a three-dimension coordinate by use of a laser tranking interferometer system based on trilateration T.Takatsuji;M.Goto;T.Kurosawa;Y.Tanimura;Koseki https://doi.org/10.1088/0957-0233/9/1/006
  8. Opt. Lett. v.28 no.7 Absolute interferometer three-dimensional profile measurement of rough surfaces B.C.Kim;S.W.Kim
  9. Appl.Opt. v.41 no.28 Absolute distance measurement by two point diffeaction interferometry H.G.Rhee;S.W.Kim https://doi.org/10.1364/AO.41.005921