• Title/Summary/Keyword: Signal Analysis

Search Result 7,924, Processing Time 0.032 seconds

Analysis of Heart Sound Using the Wavelet Transform (Wavelet Transform을 이용한 Heart Sound Analysis)

  • 위지영;김중규
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.959-962
    • /
    • 2000
  • A heart sound algorithm, which separates the heart sound signal into four parts; the first heart sound, the systolic period, the second heart sound, and the diastolic period has been developed. The algorithm uses discrete intensity envelopes of approximations of the wavelet transform analysis method to the phonocard-iogram(PCG)signal. Heart sound a highly nonstation-ary signal, so in the analysis of heart sound, it is important to study the frequency and time information. Further more, Wavelet Transform provides more features and characteristics of the PCG signal that will help physician to obtain qualitative and quantitative measurements of the heart sound.

  • PDF

Linear System Analysis Using Wavelets Transform: Application to Ultrasonic Signal Analysis (웨이브렛 변환을 이용한 선형시스템 분석: 초음파 신호 해석의 응용)

  • Joo, Young Bok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.77-83
    • /
    • 2020
  • The Linear system analysis for physical system is very powerful tool for system diagnostic utilizing relationship between the input signal and output signal. This method utilized generally to investigate physical properties of system and the nondestructive test by ultrasonic signals. This method can be explained by linear system theory. In this paper the Continuous Wavelets Transform is utilized to search the relation between the linear system and continuous wavelets transform.

An Algorithm for the Optimum Separation of Superimposed EMG Signal Using Wavelet Filter (웨이브렛 필터를 이용한 복합 중첩 근신호의 최적화 분리 알고리즘)

  • 이영석;김성환
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.319-326
    • /
    • 1996
  • Clinical myography(EMG) is a technique for diagnosing neuromuscular disorders by analyzing the electrical signal that can be records by needle electrode during a muscular contraction. The EMG signal arises from electrical discharges that accompany the generation of force by groups of muscular fiber, and the analysis of EMG signal provides symptoms that can distinguish disorder of mLecle from disor- ders of nerve. One of the methods for analysis of EMG signal is to separate the individual discharge-the motor unit action potentials(MVAPS) - from EMG signal. But we can only observe the EMG signal that is a superimposed version of time delayed MUAPS. To obtain the information about MUAP(, i.e., position, firing number, magnitude etc), first of all, a method that can separate each MUAP from the EMG signal must be developed Although the methods for MUAP separation have been proposed by many researcherl they have required heavy computational burden. In this paper, we proposed a new method that has less computational burden and performs more reliable separation of superimposed EMG signal using wavelet filter which has multiresolution analysis as major property. As a result, we develope the separation algorithm of superimposed EMG signal which has less computational burden than any other researchers and exacutes exact separation process. The performance of this method has been discussed in the automatic resolving procedure which is neccessary to identify every firing of every motor unit from the EMG pattern.

  • PDF

Design of ICA to Extract Respiration Signal From PPG Signal

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.2
    • /
    • pp.220-223
    • /
    • 2011
  • Respiration signal of the vital signs is an important parameter in clinical parts. To extract the respiration signal from PPG signal for mobile healthcare system is difficult because the bands of the motion artifacts and respiration in the frequency domain are overlapped. This study to improve this problem suggested a respiration extraction method using the independent component analysis and evaluated its performances. In results of evaluation, the ICA method showed better performance than LPF suggested recently.

Application assessments of concrete piezoelectric smart module in civil engineering

  • Zhang, Nan;Su, Huaizhi
    • Smart Structures and Systems
    • /
    • v.19 no.5
    • /
    • pp.499-512
    • /
    • 2017
  • Traditional structural dynamic analysis and Structural Health Monitoring (SHM) of large scale concrete civil structures rely on manufactured embedding transducers to obtain structural dynamic properties. However, the embedding of manufactured transducers is very expensive and low efficiency for signal acquisition. In dynamic structural analysis and SHM areas, piezoelectric transducers are more and more popular due to the advantages like quick response, low cost and adaptability to different sizes. In this paper, the applicable feasibility assessment of the designed "artificial" piezoelectric transducers called Concrete Piezoelectric Smart Module (CPSM) in dynamic structural analysis is performed via three major experiments. Experimental Modal Analysis (EMA) based on Ibrahim Time Domain (ITD) Method is applied to experimentally extract modal parameters. Numerical modal analysis by finite element method (FEM) modeling is also performed for comparison. First ten order modal parameters are identified by EMA using CPSMs, PCBs and FEM modeling. Comparisons are made between CPSMs and PCBs, between FEM and CPSMs extracted modal parameters. Results show that Power Spectral Density by CPSMs and PCBs are similar, CPSMs acquired signal amplitudes can be used to predict concrete compressive strength. Modal parameter (natural frequencies) identified from CPSMs acquired signal and PCBs acquired signal are different in a very small range (~3%), and extracted natural frequencies from CPSMs acquired signal and FEM results are in an allowable small range (~5%) as well. Therefore, CPSMs are applicable for signal acquisition of dynamic responses and can be used in dynamic modal analysis, structural health monitoring and related areas.

The Performance Advancement of Power Analysis Attack Using Principal Component Analysis (주성분 분석을 이용한 전력 분석 공격의 성능 향상)

  • Kim, Hee-Seok;Kim, Hyun-Min;Park, Il-Hwan;Kim, Chang-Kyun;Ryu, Heui-Su;Park, Young-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.20 no.6
    • /
    • pp.15-21
    • /
    • 2010
  • In the recent years, various researches about the signal processing have been presented to improve the performance of power analysis. Among these signal processing techniques, the research about the signal compression is not enough than a signal alignment and a noise reduction; even though that can reduce considerably the computation time for the power analysis. But, the existing compression method can sometimes reduce the performance of the power analysis because those are the unsophisticated method not considering the characteristic of the signal. In this paper, we propose the new PCA (principal component analysis)-based signal compression method, which can block the loss of the meaningful factor of the original signal as much as possible, considering the characteristic of the signal. Also, we prove the performance of our method by carrying out the experiment.

Performance Analysis for Secured Service Signals of RNSS Systems

  • Han, Kahee;Lee, Subin;Lee, Kihoon;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.4
    • /
    • pp.341-349
    • /
    • 2022
  • When designing a new RNSS signal, the performance analysis for the legacy signal providing the same service, is required to determine the performance requirements. However, there are few studies on the secured service (SS) signal performance analysis, and the waveform is the only published information on the signal design component of the SS signal. Therefore, in this paper, we introduce several figures-of-merit (FoMs) that can be used for performance analysis in terms of the waveform. And then, we calculate the FoMs, such as autocorrelation main peak to secondary peak ratio (AMSR), spectral efficiency, Gabor bandwidth, multipath error, and jamming resistance quality factor, for the existing SS signals and discuss the analysis results. Finally, we conclude that the superior waveform for each FoM is different, and that the consideration of the trade-off relationship between the FoMs is required for waveform design.

A Study on The Effective Classification of Signal Facilities using LCC Analysis (LCC 분석을 이용한 효과적인 신호 설비 분류에 관한 연구)

  • Kim, Doo-Suk;Kim, Young-Hoon;An, Chan-Gi;Jang, Seong-Yong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2711-2717
    • /
    • 2011
  • This paper presents the classification scheme of the signal facilities on the railroad considering the construction costs and maintenance costs in a low population area. The construction costs of the new signal facility system can be compare with the costs of the present signal facilities as the classification scheme. The signal facilities on the railroad were classified as the railroad security regulations and then the scheme is considered through the LCC analysis. In order to test this research, the costs of signal facilities obtained from ones on TAEBACK railroad line. The costs categorized the construction costs, the labor cost and the maintenance costs can be effectively applied to the LCC analysis. The scheme is very useful to make a decision whether the new signal facilities on railroad in low population area is build or not in terms of the costs.

  • PDF

IF Signal Generation for Intra-pulse Analysis System (인트라펄스 분석 시스템을 위한 IF신호 모의)

  • Jeong, Dae-young;Ko, Jae-heon;Park, Kyung-tae;You, Byung-sek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.839-840
    • /
    • 2013
  • In most EW ES equipment, S/W is developed before H/W development. The important thing is the validity of S/W algorithm should be tested before the integration between H/W and S/W. For S/W-alone test, the digital threat signal generation for the signal analysis system is needed. This paper is proposing the simulated IF signal generation which is similar with the real signal.

  • PDF

Analysis of Bobbin Probe Signal in Steam Generator Tube with Bulge Defect (증기발생기 세관의 Bulge결함에 대한 보빈프로브 신호해석)

  • Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.702-704
    • /
    • 2003
  • In this paper, analysis of bobbin probe signal in steam generator tube with bulge defect on CE system 80 nuclear power plant is represented. The CE system 80 steam generator is adopted in ULJIN-4 nuclear power plant. From Maxwell's equation, the electromagnetic governing equation for eddy current problem is derived and by performing the finite element formulation the 3-dimensional finite element code with brick element is developed. For the ease of the comparison the numerical results with experimental ones, the calculated signals are adjusted by using the ASME standard 100[%] through hole signal. For analysis of the effect of variation of the bulge depth on the impedance signal 0.2[mm] and 0.4[mm] depth of bulge defect signals are calculated and analyzed. As the depth of the bulge defect is increased, the magnitude of the signal is increased, too. But the rate of the increment of the signal is less than that of the depth of defect. From the result of this paper, we can obtained the information of the effect of bulge defect on the impedance signal.

  • PDF