DOI QR코드

DOI QR Code

Design of ICA to Extract Respiration Signal From PPG Signal

  • Lee, Ju-Won (Department of Medical Engineering, Andong Science College) ;
  • Lee, Byeong-Ro (Department of Electronics Engineering, Gyeongnam National University of Science and Technology)
  • Received : 2011.01.25
  • Accepted : 2011.03.08
  • Published : 2011.04.30

Abstract

Respiration signal of the vital signs is an important parameter in clinical parts. To extract the respiration signal from PPG signal for mobile healthcare system is difficult because the bands of the motion artifacts and respiration in the frequency domain are overlapped. This study to improve this problem suggested a respiration extraction method using the independent component analysis and evaluated its performances. In results of evaluation, the ICA method showed better performance than LPF suggested recently.

Keywords

References

  1. M. Folke, L. Cernerud, M. Ekstrom, B. Hok, "Critical review of non-invasive respiratory monitoring in medical care," Medical & Biological Engineering & Computing, Vol. 41, 2003.
  2. J. Muhlsteff, O. Such, R. Schmidt, M. Perkuhn, H. Reiter, et al, "Wearable approach for continuous ECG and activity patientmonitoring," Engineering in Medicine and Biology Society, 26th Annual International Conference of the IEEE, Volume 1, Issue, 1-5 Sept. pp. 2184-2187, 2004.
  3. Yoshimura Takahiro; Yonezawa Yoshiharu; Maki Hiromichi; Ogawa Hidekuni; Hahn Allen W; Thayer Julian F; Caldwell W Morton, "A compact ECG R-R interval, respiration and activity recording system," Biomedical sciences instrumentation Vol. 39, pp. 204-207, 2003.
  4. Anders Johansson, PerAke Oberg, and Gunnar Sedin, "Monitoring of Heart And Respiratory Rate in Newborn Infants Using a New Photoplethysmographic Technique," Journal of Clinical Monitoring and Computing 15, pp. 461-467, 1999. https://doi.org/10.1023/A:1009912831366
  5. L. Nillson, A. Johansson, and S. Kalman, "Respiration can be monitored by photoplethysmography with high sensitivity and specificity regardless of anaesthesia and ventilatory mode," Acta Anaesthesiol Scand; Vol. 49, pp.1157-1162, 2005. https://doi.org/10.1111/j.1399-6576.2005.00721.x
  6. K. Nakajima, T. Tamura, T. Ohta, H. Miike, and P.A. Oberg, "Photoplethysmographic Measure-ment of Heart and Respiratory Rates Using Digital Filters," Engineering in Medicine and Biology Society, Proceedings of the 15th Annual International Conference of the IEEE, Oct 28-31, pp. 1006-1007, 1993.
  7. Jonghwa Kim, Mincheol Whang, Kichang Nam, "PPG Filtering Method for Respiration Measurement in U-Health Care System," Journal of the Ergonomics Society of Korea, Vol. 27, No. 4, pp. 95-101, 2008. https://doi.org/10.5143/JESK.2008.27.4.095
  8. J.W. Lee, B.R. Lee, G.K. Lee, " Heart Rate Estimation Based on PPG signal and Histogram Filter for Mobile Healthcare," Int. Journal of Maritime Information and Communication Science, Vol. 8, No. 1, pp.112-115, 2010
  9. Johansson, A., Oberg, P.A. and Sedin, G., "Monitoring of heart and respiratory rates in newborn infants using a new photoplethys mographic technique," Journal of Clinical Monitoring and Computing, Vol. 15, pp. 461-467, 1999. https://doi.org/10.1023/A:1009912831366
  10. FastICA, http://www.cis.hut.fi/projects/ica/fastica/
  11. Te-Won Lee, Mark Girolami and Terrence J. Sejnowski, "Independent Component Analysis Using an Extended Infomax Algorithm for Mixed Subgaussian and Supergaussian Sources," Neural Computation, February 15, Vol. 11, No. 2, Pages 417-441, 1999. https://doi.org/10.1162/089976699300016719