• Title/Summary/Keyword: Sectional image

Search Result 344, Processing Time 0.031 seconds

The Combined Effect of Subjective Body Image and Body Mass Index (Distorted Body Weight Perception) on Suicidal Ideation

  • Shin, Jaeyong;Choi, Young;Han, Kyu-Tae;Cheon, Sung-Youn;Kim, Jae-Hyun;Lee, Sang Gyu;Park, Eun-Cheol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.2
    • /
    • pp.94-104
    • /
    • 2015
  • Objectives: Mental health disorders and suicide are an important and growing public health concern in Korea. Evidence has shown that both globally and in Korea, obesity is associated with an increased risk of developing some psychiatric disorders. Therefore, we examined the association between distorted body weight perception (BWP) and suicidal ideation. Methods: Data were obtained from the 2007-2012 Korea National Health and Nutritional Evaluation Survey (KNHANES), an annual cross-sectional nationwide survey that included 14 276 men and 19 428 women. Multiple logistic regression analyses were conducted to investigate the associations between nine BWP categories, which combined body image (BI) and body mass index (BMI) categories, and suicidal ideation. Moreover, the fitness of our models was verified using the Akaike information criterion. Results: Consistent with previous studies, suicidal ideation was associated with marital status, household income, education level, and perceived health status in both genders. Only women were significantly more likely to have distorted BWP; there was no relationship among men. In category B1 (low BMI and normal BI), women (odds ratio [OR], 2.25; 95% confidence interval [CI], 1.48 to 3.42) were more likely to express suicidal ideation than women in category B2 (normal BMI and normal BI) were. Women in overweight BWP category C2 (normal BMI and fat BI) also had an increased OR for suicidal ideation (OR, 2.25; 95% CI, 1.48 to 3.42). Those in normal BWP categories were not likely to have suicidal ideation. Among women in the underweight BWP categories, only the OR for those in category A2 (normal BMI and thin BI) was significant (OR, 1.34; 95% CI, 1.13 to 1.59). Conclusions: Distorted BWP should be considered an important factor in the prevention of suicide and for the improvement of mental health among Korean adults, especially Korean women with distorted BWPs.

Three-dimensional Imaging with an Endoscopic Optical Coherence Tomography System for Detection of Airway Stenosis (기도협착 측정을 위한 내시경 광 결맞음 단층촬영법을 이용한 3차원 이미징)

  • Kwon, Daa young;Oak, Chulho;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.243-248
    • /
    • 2019
  • The respiratory tract is an essential part of the respiratory system involved in the process of respiration. However, if stenosis occurs, it interferes with breathing and can even lead to death. Asthma is a typical example of a reversible cause of airway narrowing, and the number of patients suffering from acute exacerbation is steadily increasing. Therefore, it is important to detect airway narrowing early and prevent the patient's condition from worsening. Optical coherence tomography (OCT), which has high resolution, is suitable for observing the microstructure of tissues. In this study we developed an endoscopic OCT system. We combined a 1300-nm OCT system with a servo motor, which can rotate at a high speed. A catheter was pulled back using a linear stage while imaging with 360° rotation by the motor. The motor was selected considering various requirements, such as torque, rotational speed, and gear ratio of pulleys. An ex vivo rabbit tracheal model was used as a sample, and the sample and catheter were immobilized by acrylic structures. The OCT images provided information about the structures of the mucosa and submucosa. The difference between normal and stenosed parts in the trachea was confirmed by OCT. Furthermore, through a three-dimensional (3-D) reconstruction process, it was possible to identify and diagnose the stenosis in the 3-D image of the airway, as well as the cross-sectional image. This study would be useful not only for diagnosing airway stenosis, but also for realizing 3-D imaging.

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography (방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교)

  • Ko, Hye-Suk;You, Heyon-Mee;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to compare the centering abilities of four root canal instrument systems and the amounts of dentin removed after root canal shaping using them. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}$ curvature were scanned using X-ray micro-computed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n = 10 per group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with Profile (Group 2), ProTaper (Group 3) or K3 system (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Scanned images were processed to reconstruct three-dimensional images using three-dimensional image software and the changes of total canal volume were measured. Pre-and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were com pared. For each level, centering ratio were calculated using Adobe Photoshop 6.0 and image software program. ProTaper and K3 systems have a tendency to remove more dentin than the other file systems. In all groups, the lowest value of centering ratio at 3 mm level was observed. And except at 3 mm level, ProTaper system made canals less centered than the other systems (p < 0.05).

Effect of Mandibular Repositioning Device on Airway Size and Airway Collapsibility in Obstructive Sleep Apnea Syndrome : Cine CT during Sleep (수면무호흡증 환자에서 Mandibular Repositioning Device가 Airway size와 Airway Collapsibility에 미치는 효과)

  • Hong, Seung-Bong;Kyung, Seung-Hyun;Han, Hyun-Jung;Na, Dong-Kyu;Son, Young-Ik;Park, Young-Chel
    • Sleep Medicine and Psychophysiology
    • /
    • v.6 no.2
    • /
    • pp.110-115
    • /
    • 1999
  • Objectives: To investigate the effect of mandibular repasitioning device on airway sige and airway collapsibility in patients with obstructive sleep apnea syndrome(OSAS). Methods: Cine CT with polysomnographic monitoring was performed during sleep in nine(OSAS) patients before and after manibular repositioning device(MRD) application. Axial CT images were obtained in five upper airway levels(retropalatal-high, retroalatal-low, retroglossal, epiglottis, and hypopharynx levels). In each airway level, one axial CT image was obtained during sleep apnea period and 10 serial axial CT images were scanned every 1 second during normal sleep breathing. After wearing MRD, all CT images were obtained by the same method. The cross-sectional areas of airway were measured by automatic tracing method. The changes of minimum airway size and maximum airway size after MRD were evaluated. The airway collapsibility was calculaed before and after MRD. Results: During sleep apnea, the airway of retropalatal-low level was the most frequently narrowest site. During normal sleep breahing the minimum airway size was increased significantly after MRD at retropalatal-low level(p=0.011). The mean airway collapsibility was the highest at retropalatal-low level. MRD decreased the airway collapsibility significantly at retropalatal-low level(p=0.021) and epiglottis level(p=0.038). Conclusions: The enlargement of the minimum airway size and decreased airway collapsibility may be the therapeutic mechanism of MRD in obstructive sleep apnea.

  • PDF

Osseointegration of the titanium implant coated with rhTGF-${\beta}2$/PLGA particles by electrospray: a preliminary microCT analyzing rabbit study (rhTGF-${\beta}2$/PLGA 복합체를 electrospray법으로 코팅한 타이타늄 임플란트 골 유착의 microCT 계측: a preliminary rabbit study)

  • Lee, Woo-Sung;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man;Park, Yoon-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.298-304
    • /
    • 2014
  • Purpose: This preliminary rabbit study was conducted to evaluate the effect of recombinant human transforming growth factor-${\beta}2$ (rhTGF-${\beta}2$)/poly lactic-co-glycolic acid (PLGA) coating on osseointegration of the titanium (Ti) implant. Materials and methods: Eight Ti implants were anodized with 300 voltages for three minutes. Four of those were coated with rhTGF-${\beta}2$/PLGA by an electrospray method as the experimental group. The implants were placed into tibiae of four New Zealand rabbits, two implants per a tibia, one implant per each group. After 3 and 6 weeks, every two rabbits were sacrificed and micro-computed tomography (microCT) was taken for histomorphometric analysis. Results: In scanning electron microscope (SEM) image, the surface of rhTGF-${\beta}2$/PLGA coated Ti implant showed well distributed particles. Although statistically insignificant, microCT analysis showed that experimental group has higher bone volume / total volume (BV/TV) and trabecular thickness (Tb.Th) values relatively. Cross sectional view also showed more newly formed bone in the experimental group. Conclusion: In the limitation of this study, rhTGF-${\beta}2$/PLGA particles coating on the Ti implant show the possibility of more favorable quantity of newly formed bone after implant installation.

Electrical Properties in $Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ Structure and the Role of $SrTiO_3$ Film as a Buffer Layer ($Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ 구조의 전기적 특성 분석 및 $SrTiO_3$박막의 완충층 역할에 관한 연구)

  • 김형찬;신동석;최인훈
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.6
    • /
    • pp.436-441
    • /
    • 1998
  • $Pt/SrTiO_3/Pb_x(Zr_{0.52}, Ti_{0.48})O_3/SrTiO_3/Si$ structure was prepared by rf-magnetron sputtering method for use in nondestructive read out ferroelectric RAM(NDRO-FEAM). PBx(Zr_{0.52}Ti_{0.48})O_3}$(PZT) and $SrTiO_3$(STO) films were deposited respectively at the temperatures of $300^{\circ}C and 500^{\circ}C$on p-Si(100) substrate. The role of the STO film as a buffer layer between the PZT film and the Si substrate was studied using X-ray diffraction (XRD), Auger electron spectroscopy (ASE), and scanning electron microscope(SEM). Structural analysis on the interfaces was carried out using a cross sectional transmission electron microscope(TEM). For PZT/Si structure, mostly Pb deficient pyrochlore phase was formed due to the serious diffusion of Pb into the Si substrate. On the other hand, for STO/PZT/STO/Si structure, the PZT film had perovskite phase and larger grain size with a little Pb interdiffusion. the interfaces of the PZT and the STO film, of the STO film and the interface layer and $SiO_2$, and of the $SiO_2$ and the Si substate had a good flatness. Across sectional TEM image showed the existence of an amorphous layer and $SiO_2$ with 7nm thickness between the STO film and the Si substrate. The electrical properties of MIFIS structure was characterized by C-V and I-V measurements. By 1MHz C-V characteristics Pt/STO(25nm)/PZT(160nm)/STO(25nm)/Si structure, memory window was about 1.2 V for and applied voltage of 5 V. Memory window increased by increasing the applied voltage and maximum voltage of memory window was 2 V for V applied. Memory window decreased by decreasing PZT film thickness to 110nm. Typical leakage current was abour $10{-8}$ A/cm for an applied voltage of 5 V.

  • PDF

Accuracy of CT image in measuring the mandible for implant : Effect of mandibular position and gantry angle (임플랜트를 위한 하악골 측정시 전산화단?사진상의 정확도에 관한 연구 : 하악 위치와 gantry각이 미치는 영향)

  • Choi Soon-Chul;Choi Hang-Moon;Park Rae-Jeong;Lee Sam-Sun;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.225-234
    • /
    • 1998
  • We used five adult dog mandibles embedded in resin block and six different cross-sectional planes for each mandible were choosen. According to the angle of mandibular occulsal plane to vertical plane(mandibular angle) and gantry angle of CT machine, we classified 4 experimental groups and 1 control group. The control group images were taken at the mandibular angel 0° and gantry angle 0°. The experimental images were taken at the mandibular angle 15° and gantry angle 0°(group 1); 30° and 0°(group 2); 15° and 15°(group 3) ;30° and 30°(group 4), respectively. Using the reformatted cross-sectional images, the distance from the mandibular canal to the alveolar crest and the distance from the mandibular canal to the buccal cortex and to the lingual cortex was measured and compared. The obtained results were as follows: 1. The distance from the mandibular canal to the alveolar crest of group 1 and 2 was larger than control group, but the distance of group 3 and 4 was smaller. The distance from the mandibular canal to the buccal cortex and to the lingual cortex of all experimental groups was smaller than control group. 2. The distance from the mandibular canal to the alveolar crest showed the largest difference from control group in all experimental groups, especially in group 2 and 4(p<0.05). 3. In the distance from the mandibular canal to the alveolar crest, the number of deviation value under 1 mm was 20 in group 3 and was 11 in group 2 and 4, respectively. 4. The deviation value of the distance from the mandibular canal to the buccal cortex and to the lingual cortex was under 1 mm in most cases.

  • PDF

A Study on the Solid Shapes of Knit Flare Skirts Using 3-Dimensional Image Analysis (3차원 형상계측에 의한 니트 플레어스커트의 입체형상에 관한 연구)

  • Ki, Hee-Sook
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.13 no.2
    • /
    • pp.103-119
    • /
    • 2011
  • This study set out to analyze the solid shapes of knit flared skirts, which are best represented in a 3-dimensional shape for all knit skirts, according to the seamed and seamless production method and to estimate the silhouettes of knit flared skirts based on the results. It also aimed to help with the introduction and spread of seamless weaving by revising and supplementing potential problems and provide findings that would be put to active use as basic data, thus contributing to the development of original knitwear and offering fundamental materials for the development of the knitting industry. A number of experimental knit flared skirts were made according to skirt angle ($90^{\circ}$ and $180^{\circ}$), gauge (7G, 12G, and 15G), and grain (bias, wale, and radial), including 12 kinds of seamed knit flared skirts and 6 kinds of seamless knit flared skirts. Using a three-dimensional shape measurement system, the investigator measured the cross-sectional shapes of their hemlines. The SPSS 12 Version program was used for statistical processing, and descriptive statistics such as mean and standard deviation were used to compare the seamed and seamless knit flared skirts in the measurements (measurement items) of their solid shapes according to the width, gauges, and grain directions. The central grain direction of seamless knit flared skirts was in a radial form and even hemlines, thus presenting a beautiful appearance and solid shape. The 3-dimensional shapes show that seamless knit flared skirts are superior to seamed ones. The research findings are expected to open a door for Korea's knitting industry to quickly respond to small quantity batch production and additional orders.

  • PDF

An assessment of maxillary sinus and alveolar bone in cross-sectional linear tomogram of panorama (파노라마촬영장치의 협설선형단층상에 의한 상악동과 치조골 평가)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.33 no.3
    • /
    • pp.137-141
    • /
    • 2003
  • Purpose: To evaluate the precision of measurements taken of dental implants in bucco-lingually sectioned views of the maxilla by linear tomograms of the panorama and to assess the visibility of the inferior wall of the maxillary sinus. Materials and Methods : Eighty sites prepared with implants of gutta percha cone in the sockets of the upper premolars and molars of 10 dry skulls were radiographically examined using linear tomograms of panorama, and scanned coronally and axially by computed tomography. The differences in mm between the measurements in bucco-lingually sectioned images of maxillary alveolar bone and the true length and width of the implanted gutta percha cones were compared as mean values (mean) and standard deviations (SD) for each radiographic technique. Linear tomography of panorama was compared with computed tomography for visualization of the relationship between the inferior wall of maxillary sinus and the end of each implant. Results: The deviations between the actual implant length and the measured values taken from the linear tomograms (0.44±0.39 mm) was significantly less than the measured values from the multiplanar reconstructed images of the axially scanned computed tomogram (1.21 ± 0.90 mm). There was statistically significant difference (p < 0.05) between two techniques in the differences between the measurements and true implant length. The relationship of the inferior border of maxillary sinus with end of implant was worse identified with the linear tomogram of panorama (68%) than the multiplanar reconstructed image of axially scanned computed tomogram (99%). Conclusion: We could not find any differences in the accuracy of length measurement between the linear tomogram of panorama and computed tomogram, but computed tomogram allowed for a better visualization of the inferior wall of the maxillary sinus than the linear tomogram.

  • PDF

Chemical Vapor Deposition of Ga2O3 Thin Films on Si Substrates

  • Kim, Doo-Hyun;Yoo, Seung-Ho;Chung, Taek-Mo;An, Ki-Seok;Yoo, Hee-Soo;Kim, Yun-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.225-228
    • /
    • 2002
  • Amorphous $Ga_2O_3$ films have been grown on Si(100) substrates by metal organic chemical vapor deposition (MOCVD) using gallium isopropoxide, $Ga(O^iPr)_3$, as single precursor. Deposition was carried out in the substrate temperature range 400-800 $^{\circ}C$. X-ray photoelectron spectroscopy (XPS) analysis revealed deposition of stoichiometric $Ga_2O_3$ thin films at 500-600 $^{\circ}C$. XPS depth profiling by $Ar^+$ ion sputtering indicated that carbon contamination exists mostly in the surface region with less than 3.5% content in the film. Microscopic images of the films by scanning electron microscopy (SEM) and atomic force microscopy (AFM) showed formation of grains of approximately 20-40 nm in size on the film surfaces. The root-mean-square surface roughness from an AFM image was ${\sim}10{\AA}$. The interfacial layer of the $Ga_2O_3$/Si was measured to be ${\sim}35{\AA}$ thick by cross-sectional transmission electron microscopy (TEM). From the analysis of gaseous products of the CVD reaction by gas chromatography-mass spectrometry (GC-MS), an effort was made to explain the CVD mechanism.