• 제목/요약/키워드: Screw placement

검색결과 97건 처리시간 0.027초

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.

Computerized Tomographic Measurements of Morphometric Parameters of the C2 for the Feasibility of Laminar Screw Fixation in Korean Population

  • Kim, Young-June;Rhee, Woo-Tack;Lee, Sang-Bok;You, Seung-Hoon;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권1호
    • /
    • pp.15-18
    • /
    • 2008
  • Objective : C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation. Methods : One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length. Results : Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (${\pm}1.0$) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was $43.2^{\circ}$ and mean slope angle was $32.9^{\circ}$. Conclusion : Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.

Troublesome Occipital Neuralgia Developed by C1-C2 Harms Construct

  • Rhee, Woo-Tack;You, Seung-Hoon;Kim, Suk-Kyoung;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권2호
    • /
    • pp.111-113
    • /
    • 2008
  • Recently, Harms and Melcher modified Goel's approach, the C1 lateral mass and C2 pedicle screw fixation, and the new technique is currently in favor among neurosurgeons. Comparing to the advantages of Harms construct, the disadvantages were not extensively investigated. We experienced a patient with severe occipital pain developed after the C1 lateral mass screw placement for the traumatic atlantoaxial instability. We reviewed literatures about Harms construct with focus on the occipital neuralgia as a postoperative complication and suggest here technical tips to avoid the troublesome pain.

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws

  • Jang, Woo-Young;Kim, Il-Sup;Lee, Ho-Jin;Sung, Jae-Hoon;Lee, Sang-Won;Hong, Jae-Taek
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권3호
    • /
    • pp.166-172
    • /
    • 2011
  • Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.

Targeting a Safe Entry Point for C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability

  • Chun, Hyoung-Joon;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권6호
    • /
    • pp.351-354
    • /
    • 2011
  • Objective : This investigation was conducted to evaluate a new, safe entry point for the C2 pedicle screw, determined using the anatomical landmarks of the C2 lateral mass, the lamina, and the isthmus of the pars interarticularis. Methods : Fifteen patients underwent bilateral C1 lateral mass-C2 pedicle screw fixation, combined with posterior wiring. The C2 pedicle screw was inserted at the entry point determined using the following method : 4 mm lateral to and 4 mm inferior to the transitional point (from the superior end line of the lamina to the isthmus of the pars interarticularis). After a small hole was made with a high-speed drill, the taper was inserted with a 30 degree convergence in the cephalad direction. Other surgical procedures were performed according to Harm's description. Preoperatively, careful evaluation was performed with a cervical X-ray for C1-C2 alignment, magnetic resonance imaging for spinal cord and ligamentous structures, and a contrast-enhanced 3-dimensional computed tomogram (3-D CT) for bony anatomy and the course of the vertebral artery. A 3-D CT was checked postoperatively to evaluate screw placement Results : Bone fusion was achieved in all 15 patients (100%) without screw violation into the spinal canal, vertebral artery injury, or hardware failure. Occipital neuralgia developed in one patient, but this subsided after a C2 ganglion block. Conclusion : C2 transpedicular screw fixation can be easily and safely performed using the entry point of the present study. However, careful preoperative radiographic evaluation, regardless of methods, is mandatory.

Evaluation of the accuracy of mobile cone-beam computed tomography after spinal instrumentation surgery

  • Eom, Ki Seong;Park, Eun Sung;Kim, Dae Won;Park, Jong Tae;Yoon, Kwon-Ha
    • Journal of Trauma and Injury
    • /
    • 제35권1호
    • /
    • pp.12-18
    • /
    • 2022
  • Purpose: Pedicle screw fixation provides 3-column stabilization, multidimensional control, and a higher rate of interbody fusion. Although computed tomography (CT) is recommended for the postoperative assessment of pedicle screw fixation, its use is limited due to the radiation exposure dose. The purpose of this preliminary retrospective study was to assess the clinical usefulness of low-dose mobile cone-beam CT (CBCT) for the postoperative evaluation of pedicle screw fixation. Methods: The author retrospectively reviewed postoperative mobile CBCT images of 15 patients who underwent posterior pedicle screw fixation for spinal disease from November 2019 to April 2020. Pedicle screw placement was assessed for breaches of the bony structures. The breaches were graded based on the Heary classification. Results: The patients included 11 men and four women, and their mean age was 66±12 years. Of the 122 pedicle screws, 34 (27.9%) were inserted in the thoracic segment (from T7 to T12), 82 (67.2%) in the lumbar segment (from L1 to L5), and six (4.9%) in the first sacral segment. Although there were metal-related artifacts, the image of the screw position (according to Heary classification) after surgery could be assessed using mobile CBCT at all levels (T7-S1). Conclusions: Mobile CBCT was accurate in determining the location and integrity of the pedicle screw and identifying the surrounding bony structures. In the postoperative setting, mobile CBCT can be used as a primary modality for assessing the accuracy of pedicle screw fixation and detecting postoperative complications.

개에서 경골 조면 내측에 피질골 나사못을 장착하는 방법에 의한 내측 슬개골 탈구 치료 증례 (Treatment of Medial Patellar Luxation by Placement of a Cortical Screw on the Medial Side of the Tibial Crest in a Dog)

  • 강병재;윤대영;류다은;김용선;이승훈;김완희;권오경
    • 한국임상수의학회지
    • /
    • 제31권2호
    • /
    • pp.133-136
    • /
    • 2014
  • 8 kg, 9개월령 중성화 수컷 시바 이누견이 양측 후지의 간헐적인 파행 증상으로 내원하였다. 검사를 통해 3단계의 양측 슬개골 탈구가 진단되었다. 대퇴 사두근의 정상 배열을 회복하기 위해서 상대적으로 비침습적인 조면의 위치를 재배열하는 독특한 수술 방법을 적용하였다. 이 과정은 경골 능선을 따라 경골 조면의 내측 피질골을 절개하고, 경골 조면을 외측으로 변위시키기 위해 경골 능선의 내측에 피질골 나사못을 장착하는 방식으로 이루어졌다. 수술 후 3개월 검사에서 양측 후지의 파행과 슬개골 탈구가 개선된 것이 확인되었다. 이 수술 기법은 골격이 미성숙한 환자에서 내측 슬개골 탈구를 치료하기 위한 효과적인 방법으로 고려될 수 있다.

Additional Surgical Method Aimed to Increase Distractive Force during Occipitocervical Stabilization : Technical Note

  • Antar, Veysel;Turk, Okan
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권2호
    • /
    • pp.277-281
    • /
    • 2018
  • Objective : Craniovertebral junctional anomalies constitute a technical challenge. Surgical opening of atlantoaxial joint region is a complex procedure especially in patients with nuchal deformity like basilar invagination. This region has actually very complicated anatomical and functional characteristics, including multiple joints providing extension, flexion, and wide rotation. In fact, it is also a bottleneck region where bones, neural structures, and blood vessels are located. Stabilization surgery regarding this region should consider the fact that the area exposes excessive and life-long stress due to complex movements and human posture. Therefore, all options should be considered for surgical stabilization, and they could be interchanged during the surgery, if required. Methods : A 53-year-old male patient applied to outpatients' clinic with complaints of head and neck pain persisting for a long time. Physical examination was normal except increased deep tendon reflexes. The patient was on long-term corticosteroid due to an allergic disease. Magnetic resonance imaging and computed tomography findings indicated basilar invagination and atlantoaxial dislocation.The patient underwent C0-C3-C4 (lateral mass) and additional C0-C2 (translaminar) stabilization surgery. Results : In routine practice, the sites where rods are bound to occipital plates were placed as paramedian. Instead, we inserted lateral mass screw to the sites where occipital screws were inserted on the occipital plate, thereby creating a site where extra rod could be bound.When C2 translaminar screw is inserted, screw caps remain on the median plane, which makes them difficult to bind to contralateral system. These bind directly to occipital plate without any connection from this region to the contralateral system.Advantages of this technique include easy insertion of C2 translaminar screws, presence of increased screw sizes, and exclusion of pullout forces onto the screw from neck movements. Another advantage of the technique is the median placement of the rod; i.e., thick part of the occipital bone is in alignment with axial loading. Conclusion : We believe that this technique, which could be easily performed as adjuvant to classical stabilization surgery with no need for special screw and rod, may improve distraction force in patients with low bone density.

Maxillary expansion with the memory screw: a preliminary investigation

  • Halicioglu, Koray;Kiki, Ali;Yavuz, Ibrahim
    • 대한치과교정학회지
    • /
    • 제42권2호
    • /
    • pp.73-79
    • /
    • 2012
  • Objective: The purpose of this study was to investigate the effects of a newly developed rapid maxillary expansion screw-the memory screw-over 6 months. Methods: Five subjects, aged between 11.7 and 13.75 years, were enrolled in this study. All subjects underwent placement of a maxillary expansion appliance containing superelastic nickel-titanium open-coil springs in its screw bed. The parents of the patients and/or the patients themselves were instructed to activate the expansion screw by 2 quarter-turns 3 times a day (morning, midday, and evening; 6 quarter-turns a day). The mean expansion period was $7.52{\pm}1.04$ days. Dentoskeletal effects of the procedure, including dentoalveolar inclination, were evaluated. Measurements of all the parameters were repeated after 6 months of retention in order to check for relapse. Results: Sella-Nasion-A point (SNA) and Sella-Nasion/Gonion-Menton angles increased, and Sella-Nasion-B point (SNB) angle decreased in all the subjects during the expansion phase. However, they approximated to the initial values at the end of 6 months. On the other hand, the increments in maxillary apical base (Mxr-Mxl) and intermolar widths was quite stable. As expected, some amount of dentoalveolar tipping was observed. Conclusions: The newly developed memory expansion screw offers advantages of both rapid and slow expansion procedures. It widens the midpalatal suture and expands the maxilla with relatively lighter forces and within a short time. In addition, the resultant increments in the maxillary apical base and intermolar width remained quite stable even aft er 6 months of retention.

Comparison of success rates of orthodontic mini-screws by the insertion method

  • Kim, Jung Suk;Choi, Seong Hwan;Cha, Sang Kwon;Kim, Jang Han;Lee, Hwa Jin;Yeom, Sang Seon;Hwang, Chung Ju
    • 대한치과교정학회지
    • /
    • 제42권5호
    • /
    • pp.242-248
    • /
    • 2012
  • Objective: The aim of this study was to compare the success rates of the manual and motor-driven mini-screw insertion methods according to age, gender, length of mini-screws, and insertion sites. Methods: We retrospectively reviewed 429 orthodontic mini-screw placements in 286 patients (102 in men and 327 in women) between 2005 and 2010 at private practice. Age, gender, mini-screw length, and insertion site were cross-tabulated against the insertion methods. The Cochran-Mantel-Haenszel test was performed to compare the success rates of the 2 insertion methods. Results: The motor-driven method was used for 228 mini-screws and the manual method for the remaining 201 mini-screws. The success rates were similar in both men and women irrespective of the insertion method used. With respect to mini-screw length, no difference in success rates was found between motor and hand drivers for the 6-mm-long mini-screws (68.1% and 69.5% with the engine driver and hand driver, respectively). However, the 8-mmlong mini-screws exhibited significantly higher success rates (90.4%, p < 0.01) than did the 6-mm-long mini-screws when placed with the engine driver. The overall success rate was also significantly higher in the maxilla (p < 0.05) when the engine driver was used. Success rates were similar among all age groups regardless of the insertion method used. Conclusions: Taken together, the motor-driven insertion method can be helpful to get a higher success rate of orthodontic mini-screw placement.