Browse > Article
http://dx.doi.org/10.3340/jkns.2011.50.3.166

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws  

Jang, Woo-Young (Department of Neurosurgery, The Catholic University of Korea, St. Vincent's Hospital)
Kim, Il-Sup (Department of Neurosurgery, The Catholic University of Korea, St. Vincent's Hospital)
Lee, Ho-Jin (Department of Neurosurgery, The Catholic University of Korea, St. Vincent's Hospital)
Sung, Jae-Hoon (Department of Neurosurgery, The Catholic University of Korea, St. Vincent's Hospital)
Lee, Sang-Won (Department of Neurosurgery, The Catholic University of Korea, St. Vincent's Hospital)
Hong, Jae-Taek (Department of Neurosurgery, The Catholic University of Korea, St. Vincent's Hospital)
Publication Information
Journal of Korean Neurosurgical Society / v.50, no.3, 2011 , pp. 166-172 More about this Journal
Abstract
Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.
Keywords
Intralaminar screw; Pedicle screw; Lateral mass screw; Anatomic study;
Citations & Related Records

Times Cited By Web Of Science : 1  (Related Records In Web of Science)
Times Cited By SCOPUS : 1
연도 인용수 순위
  • Reference
1 Merola AA, Castro BA, Alongi PR, Mathur S, Brkaric M, Vigna F, et al. : Anatomic consideration for standard and modified techniques of cervical lateral mass screw placement. Spine J 2 : 430-435, 2002   DOI   ScienceOn
2 Onibokun A, Khoo LT, Bistazzoni S, Chen NF, Sassi M : Anatomical considerations for cervical pedicle screw insertion : the use of multiplanar computerized tomography measurements in 122 consecutive clinical cases. Spine J 9 : 729-734, 2009   DOI   ScienceOn
3 Wang MY : C2 crossing laminar screws : cadaveric morphometric analysis. Neurosurgery 59 : ONS84- ONS88; discussion ONS84-ONS88, 2006
4 Wright NM : Posterior C2 fixation using bilateral, crossing C2 laminar screws : case series and technical note. J Spinal Disord Tech 17 : 158-162, 2004   DOI
5 Cardoso MJ, Dmitriev AE, Lehman RA, Helgeson M, Cooper P, Rosner MK : Computed tomography and biomechanical evaluation of screw fixation options at the cervicothoracic junction : intralamina versus intrapedicular techniques. Spine (Phila Pa 1976) 33 : 2612-2617, 2008   DOI   ScienceOn
6 Cassinelli EH, Lee M, Skalak A, Ahn NU, Wright NM : Anatomic considerations for the placement of C2 laminar screws. Spine (Phila Pa 1976) 31 : 2767-2771, 2006   DOI   ScienceOn
7 Dean CL, Lee MJ, Robbin M, Cassinelli EH : Correlation between computed tomography measurements and direct anatomic measurements of the axis for consideration of C2 laminar screw placement. Spine J 9 : 258-262, 2009   DOI   ScienceOn
8 Desai S, Sethi A, Ninh CC, Bartol S, Vaidya R : Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique. Eur Spine J 19 : 1953-1959, 2010   DOI   ScienceOn
9 Grubb MR, Currier BL, Stone J, Warden KE, An KN : Biomechanical evaluation of posterior cervical stabilization after a wide laminectomy. Spine (Phila Pa 1976) 22 : 1948-1954, 1997   DOI   ScienceOn
10 Hong JT, Sung JH, Son BC, Lee SW, Park CK : Significance of laminar screw fixation in the subaxial cervical spine. Spine (Phila Pa 1976) 33 : 1739-1743, 2008   DOI   ScienceOn
11 Jones EL, Heller JG, Silcox DH, Hutton WC : Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine (Phila Pa 1976) 22 : 977-982, 1997   DOI   ScienceOn
12 Albert TJ, Klein GR, Joffe D, Vaccaro AR : Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology. Spine (Phila Pa 1976) 23 : 1596-1599, 1998   DOI   ScienceOn
13 Ames CP, Bozkus MH, Chamberlain RH, Acosta FL Jr, Papadopoulos SM, Sonntag VK, et al. : Biomechanics of stabilization after cervicothoracic compression-flexion injury. Spine (Phila Pa 1976) 30 : 1505-1512, 2005   DOI   ScienceOn
14 Cardoso MJ, Dmitriev AE, Helgeson MD, Stephens F, Campbell V, Lehman RA, et al. : Using lamina screws as a salvage technique at C-7 : computed tomography and biomechanical analysis using cadaveric vertebrae. Laboratory investigation. J Neurosurg Spine 11 : 28-33, 2009   DOI   ScienceOn