• Title/Summary/Keyword: SPR sensor chip

Search Result 19, Processing Time 0.031 seconds

A Disposable Grating-Integrated Multi-channel SPR Sensor Chip for Detection of Biomolecule (회절격자가 집적된 일회용 다중채널 SPR 생체분자 검출 칩)

  • Jin, Young-Hyun;Cho, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.147-154
    • /
    • 2009
  • This paper presents a grating~integrated SPR (Surface Plasmon Resonance) sensor chip for simple and inexpensive biomolecule detection. The grating-integrated SPR sensor chip has two sensing channels having a nano grating for SPR coupling. An external mirror is used for multi channel SPR sensing. The present sensor chip replaces bulky and expensive optical components, such as fiber-optic switches or special shaped prisms, resulting in a simple and inexpensive wavelength modulated multi-channel SPR sensing system. We fabricate a SPR sensor chip integrated with 835 nm-pitch gratings by a micromolding technique to reduce the fabrication cost. In the experimental characterization, the refractive index sensitivity of each sensing channel is measured as $321.8{\pm}8.1nm$/RI and $514.3{\pm}8.lnm$/RI, respectively. 0.5uM of the target biomolecule (streptavidin) was detected by a $1.13{\pm}0.16nm$ shift of the SPR dip in the 10%-biotinylated sample channel, while the SPR dip in the reference channel for environmental perturbation monitoring remained at the same position. From the experimental results, multi-channel biomolecule detection capability of the present grating-integrated SPR sensor chip has been verified. On the basis of the preliminary experiments, we successfully measured the binding reaction rate for the $2\;nM{\sim}200\;nM$ monoclonal-antibiotin, thus verifying biomolecule concentration detectability of the present SPR sensor chip. The binding reaction rates measured from the present SPR sensor chip agredd well with those from a commercialized SPR sensor.

Characteristics of Gold and Silver Based Bi- and Tri-metallic SPR Chip in the Intensity Measurement Mode (반사광 측정 모드에서 금과 은을 사용한 이층 금속 칩과 삼층 금속 칩의 특성 연구)

  • Kim, Hyungjin;Kim, Chang-duk;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.143-147
    • /
    • 2016
  • Characteristics of the conventional gold (Au) surface plasmon resonance (SPR) chip, bi-metallic(Au/silver (Ag)) SPR chip, and tri-metallic(Au/Ag/Au) SPR chip were investigated and compared in the intensity measurement mode for the enhancement of SPR image sensor reactivity. Reflectance curves of the Au, bi- and tri-metallic SPR chips were acquired in phosphate-buffered saline (PBS) solution and were compared. The line width of the reflectance curve of the bi-metallic chip was the narrowest among the three different types of the chips. Also, the tangential slope of the bi-metallic chip was steeper than those of the other chips. Various concentrations of bovine serum albumin (BSA) were utilized in the SPR experiment. As a result, among the above three chips reflectance variation value of the bi-metallic chip was the largest.

Effect of SPR Chip with Nano-structured Surface on Sensitivity in SPR Sensor (나노형상을 가진 표면플라즈몬공명 센서칩의 감도 개선 효과)

  • Cho, Yong-Jin;Kim, Chul-Jin;Kim, Namsoo;Kim, Chong-Tai;Kim, Tae-Eun;Kim, Hyo-Sop;Kim, Jae-Ho
    • Food Engineering Progress
    • /
    • v.14 no.1
    • /
    • pp.49-53
    • /
    • 2010
  • Surface plasmon resonance (SPR) which is utilized in thin film refractometry-based sensors has been concerned on measurement of physical, chemical and biological quantities because of its high sensitivity and label-free feature. In this paper, an application of SPR to detection of alcohol content in wine and liquor was investigated. The result showed that SPR sensor had high potential to evaluate alcohol content. Nevertheless, food industry may need SPR sensor with higher sensitivity. Herein, we introduced a nano-technique into fabrication of SPR chip to enhance SPR sensitivity. Using Langmuir-Blodgett (LB) method, gold film with nano-structured surface was devised. In order to make a new SPR chip, firstly, a single layer of nano-scaled silica particles adhered to plain surface of gold film. Thereafter, gold was deposited on the template by an e-beam evaporator. Finally, the nano-structured surface with basin-like shape was obtained after removing the silica particles by sonication. In this study, two types of silica particles, or 130 nm and 300 nm, were used as template beads and sensitivity of the new SPR chip was tested with ethanol solution, respectively. Applying the new developed SPR sensor to a model food of alcoholic beverage, the sensitivity showed improvement of 95% over the conventional one.

Characteristics of a Bimetal-Layer Chip of a Surface Plasmon Resonance Sensor in the Intensity Interrogation for Tumor Marker Detection

  • Kim, Hyungjin;Kim, Chang-duk;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.243-246
    • /
    • 2016
  • The characteristics of a bimetallic surface plasmon resonance (SPR) chip were investigated to detect a tumor biomarker, carcinoembryonic antigen (CEA). The linewidth and the tangential slope of the reflectance curve of the bimetallic SPR chip was compared with those of the reflectance curve of a conventional gold (Au) SPR chip. The changes in reflectance in response to the variation in CEA in the critical concentration range were analyzed at an angle where the tangential slope of the reflectance curve was maximum. From linear regression analysis, the sensitivity of the bimetallic SPR chip with respect to the CEA in critical concentration was obtained.

Development of Protein Chip for Diagnosis of Chlamydophia Pneumoniae (단백질 칩을 이용한 클라미디아 폐렴의 진단)

  • Kim, Woo Jin;Lee, Hui Young;Lee, Seung-Joon;Jung, Se-Hui;Yuk, Jong Seol;Ha, Kwon-Soo;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.4
    • /
    • pp.412-418
    • /
    • 2006
  • Background; The diagnosis of chlamydial infection is based on serology. The current gold standard of diagnosis is MIF(microimmunofluorescence), but this modality is subjective and time-consuming. Protein microarray with using a SPR(surface plasmon resonance) sensor has recently been suggested as a method for detecting infection. For developing a protein chip to diagnose chlamydial infection, EBs(elementary bodies) were immobilized on a gold chip and the interaction between an antibody for Chlamydophila pneumoniae and the EBs(elementary bodies) immobilized on the surface of the gold chip was measured by using an SPR sensor. Methods; For the surface antigen, the EBs of Chlamydophila pneumoniae LKK1 were purified. Charged arrays were prepared by using PDDA(polydiallyldimethylammonium chloride) which has a positive charge. After immobilization of the chlamydial EBs on the PDDA surface, the investigation of the surface was done with using atomic force microscopy. After the antibody for C. pneumoniae was applied on chip, we monitored the SPR wavelength-shift to detect any antigen-antibody interaction with using a self-assembled SPR sensor. Results; The chlamydial EBs on the positively charged PDDA were visible on the surface with using atomic force microscopy. The SPR wavelength increased after interaction of antibody for C. pneumoniae with the EBs immobilized on charged gold surface. The wavelength-shift was correlated with the concentration of antigens. Conclusion; The surface immobilization of EBs on the gold surface with the charged arrays was identified and the antigen-antibody interaction on the gold chip was detected via the SPR sensor. Further investigations are needed to apply this technique to the clinical field.

Characteristics of Gold and Silver Bimetallic Surface Plasmon Resonance Chip in Intensity Measurement Mode and Calculation of Refractive Index using Critical Angle (반사광 측정 모드에서 금과 은의 쌍금속 표면 플라즈몬 공명 칩의 특성과 임계각을 이용한 굴절률 계산)

  • Kim, Hyungjin;Lee, Sung-Youp;Kim, Hong Tak;Yang, Ki-Won;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.423-428
    • /
    • 2015
  • A bimetallic chip made of gold and silver was investigated in intensity interrogation mode to confirm enhancement of the SPR sensor resolution. Both reflectance curves of the bimetallic chip and the conventional gold chip was acquired and compared. The line width of the reflectance curve of the bimetallic chip was narrower than that of the conventional Au chip, resulting in steeper tangential slope. The reflectance was monitored at the angle related to the steepest tangential slope. The change in reflectance of the bimetallic chip was larger than that of the Au chip. The critical angle was analyzed by differentiating the reflectance with respect to incident angle twice. Acquiring the critical angle regarding to the sample informs the refractive index of the sample. Using various concentration of Bovine Serum Albumin, we confirmed that refractive index was linearly related to variation of reflectance of the bimetallic chip.

Detection of IgG Using Thiolated Protein G Modified SPR Sensor Chip (Thiolated protein G로 개질된 SPR 센서 칩을 이용한 IgG 검출)

  • Sin, Eun-Jung;Lee, Yeon-Kyung;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.434-438
    • /
    • 2011
  • A portable surface plasmon resonance(SPR) based immunosensor using thiolated protein G and protein G was developed for the detection of immunoglobulin G(IgG). The protein G has specific affinity with Fc fragment of IgG and was thiolated by 2-Iminothiolane for introduction of thiol groups. Anti-IgG, bovine serum albumin(BSA), and IgG have been sequently injected after surface modification of gold sensor chip with protein G and thiolated protein G. The output signal was increased with the injection of each protein and the actual signal was measured by subtracting signal of reference channel from signal of sample injected channel. The experimental results showed the higher detection capability of IgG using thiolated protein G compared with protein G. From these results, we can conclude that the current surface modification technique and the portable SPR sensor system can be applied to various immunosensors for diagnosis.

Nano SPR Biosensor for Detecting Lung Cancer-Specific Biomarker (폐암 바이오마커 검출용 나노SPR 바이오센서)

  • Jang, Eun-Yoon;Yeom, Se-Hyuk;Eum, Nyeon-Sik;Han, Jung-Hyun;Kim, Hyung-Kyung;Shin, Yong-Beom;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.144-149
    • /
    • 2013
  • In this research, we developed a biosensor to detect lung cancer-specific biomarker using Anodic Aluminum Oxide (AAO) chip based on interference and nano surface plasmon resonance (nanoSPR). The nano-porous AAO chip was fabricated $2{\mu}m$ of pore-depth by two-step anodizing method for surface uniformity. NanoSPR has sensitivity to the refractive index (RI) of the surrounding medium and also provides simple and label-free detection when specific antibodies are immobilized to the Au-deposited surface of nano-porous AAO chip. To detect the lung cancer-specific biomarker, antibodies were immobilized on the surface of the chip by Self Assembled Monolayer (SAM) method. Since then lung cancer-specific biomarker was applied atop the antibodies immobilized layer. The specific reaction of the antigen-antibody contributed to the change in the refractive index that cause shift of resonance spectrum in the interference pattern. The Limit of Detection (LOD) was 1 fg/ml by using our nano-porous AAO biosensor chip.

A fiber optic surface plasmon resonance (SPR) sensorusing cyclic olefin copolymer (COC) polymer prism (Cyclic olefin copolymer (COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명 (SPR) 바이오 센서)

  • Yun, Sung-Sik;Lee, Soo-Hyun;Ahn, Chong-H.;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.369-374
    • /
    • 2008
  • A novel fiber optic surface plasmon resonance (SPR) sensor using cyclic olefin copolymer (COC) prism with the spectral modulation is presented. The SPR sensor chip is fabricated using the SU-8 photolithography, Ni-electroplating and COC injection molding process. The sidewall of the COC prism is partially deposited with Au/Cr (45/2.nm thickness) by e-beam evaporator, and the thermal bonding process is conducted for micro fluidic channels and optical fibers alignment. The SPR spectrum for a phosphate buffered saline (0.1.M PBS, pH.7.2) solution shows a distinctive dip at 1300.nm wavelength, which shifts toward longer wavelength with respect to the bovine serum albumin (BSA)concentrations. The sensitivity of the wavelength shift is $1.16\;nm{\cdot}{\mu}g^{-1}{\cdot}{\mu}l^{-1}$. From the wavelength of SPR dips, the refractive indices (RI) of the BSA solutions can be theoretically calculated using Kretchmann configuration, and the change rate of the RI was found to be $2.3{\times}10^{-5}RI{\cdot}{\mu}g^{-1}{\cdot}l^{-1}$. The realized fiber optic SPR sensor with a COC prism has clearly shown the feasibility of a new disposable, low cost and miniaturized SPR biosensor for biochemical molecular analyses.

Direct Triazine Herbicide Detection Using a Self-Assembled Photosynthetic Reaction Center from Purple Bacterium

  • Nakamura, Chikashi;Hasegawa, Miki;Shimada, Kazumi;Shirai, Makoto;Miyake, Jun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.6
    • /
    • pp.413-417
    • /
    • 2000
  • In this study, a direct detection system for triazine derivative herbicides was developed using the photosynthetic reaction center (RC) from the purple bacterium, Rhodobacter sphaeroides, and surface plasmon resonance (SPR) apparatus. The histidine-tagged RCs were immobilized on an SPR gold chip using nickel-nitrilotriacetic acid groups as a binder for one of the triazine herbicide, atrazine. The SPR responses were proportional to the sample concentrations of atrazine in the range 0.1-1 $\mu\textrm{g}$/mL. The sensitivity of the direct detection of atrazine using the RC-assembled sensor chip was higher than that using the antibody-immobilized chip. The other types of herbicides, DCMU or MCPP, were not detected with such high sensitivity. The results indicated the high binding selectivity of the RC complex.

  • PDF