1 |
X. Guo, "Surface plasmon resonance based biosensor technique: a review", J. Biophotonics, Vol. 5, No. 7, pp. 483-501, 2012.
DOI
|
2 |
A. Olaru, C. Bala, N. Jafferezic-Renault, and H. Y. Aboul- Enein, "Surface plasmon resonance (SPR) biosensors in pharmaceutical analysis", Crit. Rev. Anal. Chem, Vol. 45, NO. 2, pp. 97-105, 2015.
DOI
|
3 |
F. C. Dudak, and I. H. Boyaci, "Rapid and label-free bacteria detection by surface plasmon resonance (SPR) biosensors", Biotechnol. J., Vol. 4, No. 7, pp. 1003-1011, 2009.
DOI
|
4 |
C. -T. Li, K. -C. Lo, H. -Y. Chang, H. -T. Wu, J. H. Ho, and T. -J. Yen, "Ag/Au bi-metallic film based color surface plasmon resonance biosensor with enhanced sensitivity, color contrast and great linearity", Biosens. Bioelectron., Vol. 36, No. 1, pp. 192-198, 2012.
DOI
|
5 |
K. -S. Lee, T. S. Lee, I. Kim, and W. M. Kim, "Parametric study on the bimetallic waveguide coupled surface plasmon resonance sensors in comparison with other configuration", J. Phys. D: Appl. Phys., Vol. 46, No. 12, 125302, 2013.
DOI
|
6 |
Y. K. Lee, K. -S. Lee, W. M. Kim, and Y. -S. Sohn, "Detection of Amyloid-42 Using a Waveguide-Coupled Bimetallic Surface Plasmon Resonance Sensor Chip in the Intensity Measurement Mode", PLoS ONE, Vol. 9, No. 6, e98992, 2014.
DOI
|
7 |
Y. K. Lee, Y. -S. Sohn, K. -S. Lee, W. M. Kim, and J.-O. Lim, "Waveguide-coupled Bimetallic Film for Enhancing the Sensitivity of a Surface Plasmon Resonance Sensor in a Fixed-angle Mode", J. Korean Phys. Soc., Vol. 62, No. 3, pp. 475-480, 2013.
DOI
|
8 |
N. H. Kamaruddin, A. A. A. Baker, H. Y. Mohd, A. M. Mohd, S. D. Z. Mohd, and S. Sahbudin, "Enhancement of chitosan-graphene oxide SPR sensor with a multi-metallic layers of Au-Ag-Au nanostructure for lead(II) ion detection", Appl. Surf. Sci., Vol. 361, pp. 177-184, 2016.
DOI
|
9 |
U. Sjobring, L. Bjorck, and W. Kastern, "Streptococcal Protein G", J. Biol. Chem., Vol. 266, No. 1, pp. 399-405, 1991.
|
10 |
B. Guss, M. Eliasson, A. Olsson, M. Uhlen, A. K. Frej, H. Jornvall, J. I. Flock, and M. Lindberg, "Structure of the IgG-binding regions of streptococcal protein G", EMBO J., Vol. 5, No. 7, pp. 1567-1575, 1986.
|
11 |
L. Bjorck, and L. Kronvall, "Purification and some properties of streptococcal protein G, a novel IgG-binding reagent", J. Immunol., Vol. 133, No. 2, pp. 969-974, 1984.
|
12 |
Z. Altintas, Y. Uludag, Y. Gurbuz, and I. E. Tothill, "Surface plasmon resonance based immunosensor for the detection of the cancer biomarker carcinoembryonic antigen", Talanta, Vol. 86, pp. 377-383, 2011.
DOI
|
13 |
http://unicorn.ps.uci.edu/calculations/fresnel/fcform.html (retrieved on Oct. 11, 2015).
|
14 |
N. Laboria, A. Fragoso, W. Kemmner, D. Latta, O. Nilsson, M. L. Botero, K. Drese, and C. K. O'Sullivan, "Amperometric Immunosensor for Carcinoembryonic Antigen in Colon Cancer Samples Based on Monolayers of Dendritic Bipodal Scaffolds", Anal. Chem., Vol. 82, No. 5, pp. 1712-1719, 2010.
DOI
|