• 제목/요약/키워드: SPR sensor

검색결과 69건 처리시간 0.026초

반사광 측정 모드에서 금과 은의 쌍금속 표면 플라즈몬 공명 칩의 특성과 임계각을 이용한 굴절률 계산 (Characteristics of Gold and Silver Bimetallic Surface Plasmon Resonance Chip in Intensity Measurement Mode and Calculation of Refractive Index using Critical Angle)

  • 김형진;이성엽;김홍탁;양기원;손영수
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.423-428
    • /
    • 2015
  • A bimetallic chip made of gold and silver was investigated in intensity interrogation mode to confirm enhancement of the SPR sensor resolution. Both reflectance curves of the bimetallic chip and the conventional gold chip was acquired and compared. The line width of the reflectance curve of the bimetallic chip was narrower than that of the conventional Au chip, resulting in steeper tangential slope. The reflectance was monitored at the angle related to the steepest tangential slope. The change in reflectance of the bimetallic chip was larger than that of the Au chip. The critical angle was analyzed by differentiating the reflectance with respect to incident angle twice. Acquiring the critical angle regarding to the sample informs the refractive index of the sample. Using various concentration of Bovine Serum Albumin, we confirmed that refractive index was linearly related to variation of reflectance of the bimetallic chip.

직접속도 피드백을 이용한 보의 능동진동제어 (Active Vibration Control of a Beam using Direct Velocity Feedback)

  • 이영섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.587-592
    • /
    • 2004
  • Direct velocity feedback (DVFB) control is known that it offers an unconditional stability with very high performance when the control strategy is applied at a point collocated sensor and actuator pair, because the sensor-actuator pair has strictly positive real (SPR) property. In this paper, two types of collocated sensor-actuator pairs are considered for practical active vibration control of a structure. They are a point collocated sensor-actuator pair and a point sensor-distributed actuator pair. Both pairs with DVFB sho robust stability and performance. It is noted that the collocated point sensor-actuator ultimately acts as a 'skyhook' damper, but the point sensor-distributed actuator pair with DVFB acts as a 'skyhook' rotational dmaper pair.ational dmaper pair.

  • PDF

보의 능동진동제어을 통한 직접속도 피드백의 적용성 연구 (Active Vibration Control of a Beam Using Direct Velocity Feedback)

  • 이영섭
    • 한국소음진동공학회논문집
    • /
    • 제14권7호
    • /
    • pp.619-625
    • /
    • 2004
  • Direct velocity feedback (DVFB) control is known that it offers an unconditional stability with very high performance when the control strategy is applied at a point collocated sensor and actuator pair. because the sensor-actuator pair has strictly positive real (SPR) property In this paper, two types of collocated sensor-actuator pairs are considered for practical active vibration control of a structure. They are a Point collocated sensor-actuator pair and a point sensor-distributed actuator pair. Both pairs with DVFB show robust stability and performance. It is noted that the collocated point sensor-actuator ultimately acts as a “skyhook” damper, hut the point sensor-distributed actuator pair with DVFB acts as a “skyhook” rotational damper pair.

DYNAFLECT에 의한 아스팔트 콘크리트 포장도로의 분산도 특성에 관한 연구 (A Study on the Spreadability Characteristics of Asphalt Concrete Pavement using Dynaflect)

  • 김수일;최정훈;유지형
    • 한국지반공학회지:지반
    • /
    • 제3권1호
    • /
    • pp.53-64
    • /
    • 1987
  • 도로포장의 구조평가 및 유지관리를 위하여 매우 효율적인 장비로 알려진 Dynaflect의 이용이 날 로 증가하고 있어, 이에 대한 연구가 절실하다. 따라서 본 연구에서는 도로포장에 사용되는 재료의 탄성계수에 따른 해석모질을 설정하고, 이를 다층토 이론에 근거한 콤퓨터 프로그램을 통하여 Dyn select의 처짐곡선을 산출함으로써 표층 두께와 탄성계수에 따른 분산도의 특성을 연구하였다.

  • PDF

Spectroscopic and Electrochemical Detection of Thrombin/5'-SH or 3'-SH Aptamer Immobilized on (porous) Gold Substrates

  • Park, Buem-Jin;Sa, Young-Seung;Kim, Yong-Hwan;Kim, Young-Hun
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권1호
    • /
    • pp.100-104
    • /
    • 2012
  • Thrombin is a serine protease that catalyzes the conversion of soluble fibrinogen to insoluble fibrin, and thus induces physiological and pathological blood coagulation. Therefore, it is important to detect thrombin in blood serum for purposes of diagnosis. To achieve this goal, it has been suggested that a 15-mer aptamer strongly binds with thrombin to form a G-quartet structure of the aptamer. Generally, 5'-end thiol-functionalized aptamer has been used as an anti-thrombin binder. Herein, we evaluate the possibility of utilizing a 3'-SH aptasensor for thrombin detection using SPR spectroscopy, and compare the enhancement of the electrochemical signal of the thrombin-aptamer bound on a porous gold substrate. Although the two aptamers have similar configurations, in SPR analysis, the 3'-SH aptamer was a effective aptasensor as well as 5'-SH aptamer. Results from electrochemical analysis showed that the porous gold substrate acted as a good substrate for an aptasensor and demonstrated 5-fold enhancement of current change, as compared to gold thin film.

표면 플라즈몬 공명 센서를 이용한 주류의 알코올 함량 측정 (Measurement of Alcohol Contents in Alcoholic Beverages Using a Surface Plasmon Resonance Sensor)

  • 조용진;안병학;김철진;김종태
    • Journal of Biosystems Engineering
    • /
    • 제29권4호
    • /
    • pp.323-328
    • /
    • 2004
  • A surface plasmon resonance (SPR) sensing system, which belonged to a family of thin film refractometry-based sensors, was fabricated to measure the alcohol contents in alcoholic beverages. In this study, a SPR owe was obtained by a photodiode array with 128 pixels and transformed into a refractive index which was calculated by means of the first moment of values below a baseline of 0.85. When the sensing system was applied to Soju, Cheonju, Igwaduju and Tacju highly linear relationships between the refractive index by SPR and the contents of alcohol were obtained. That is, the coefficients of determination in their linear models were 0.992, 0.933, 0.918 and 0.954, respectively. Meanwhile, the effect of sample preparations on the accuracy of measurement was analyzed. As for Soju and Tacju, the best calibration equations were obtained when no sample preparation was applied. The best calibration models for measurement of Cheonju and Igwaduju were obtained through the samples filtered by $C_{18}$ disks.

Fabrication of Multicomponent Protein Microarrays with Microfluidic Devices of Poly(dimethylsiloxane)

  • Jeon, Se-Hoon;Kim, Ui-Seong;Jeon, Won-Jin;Shin, Chee-Burm;Hong, Su-Rin;Choi, In-Hee;Lee, Su-Seung;Yi, Jong-Heop
    • Macromolecular Research
    • /
    • 제17권3호
    • /
    • pp.192-196
    • /
    • 2009
  • Recently, the multi-screening of target materials has been made possible by the development of the surface plasmon resonance (SPR) imaging method. To adapt this method to biochemical analysis, the multi-patterning technology of protein microarrays is required. Among the different methods of fabricating protein microarrays, the microfluidic platform was selected due to its various advantages over other techniques. Microfluidic devices were designed and fabricated with polydimethylsiloxane (PDMS) by the replica molding method. These devices were designed to operate using only capillary force, without the need for additional flow control equipment. With these devices, multiple protein-patterned sensor surfaces were made, to support the two-dimensional detection of various protein-protein interactions with SPR. The fabrication technique of protein microarrays can be applied not only to SPR imaging, but also to other biochemical analyses.

소 혈청 알부민의 금 표면 플라즈몬 공명 칩과의 반응에 대한 pH의 영향 (Impact of pH on the response of bovine serum albumin to gold surface plasmon resonance chip)

  • 손영수
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.326-330
    • /
    • 2021
  • Reactions between gold (Au) surface plasmon resonance (SPR) chips and bovine serum albumin (BSA) dissolved in solutions of different pH were investigated. The charge on the BSA depends on the pH of the solution in which it is dissolved. Thus, dissolving BSA in different pH solutions resulted in different charges of BSA. Among the BSA dissolved in solutions with pH 4.01, 7.4, and 10.01, the SPR response was the highest for BSA dissolved in the solution of pH 4.01. To eliminate the response variation owing to the difference in the refractive indices of the solutions, phosphate buffered saline (PBS) was injected into the system after the reaction of BSA with the Au SPR chip had happened. In this case too, the BSA dissolved in the solution with pH 4.01 exhibited the highest response. This may be attributed to the non-uniform distribution of ionic patches on the BSA, which can induce electrostatic attraction to the surface even though BSA has a positive charge at pH 4.01, and the absolute values of the net charge of BSA at pH 4.01 and 7.4 were very close.

플라즈모닉스 현상을 이용한 전반사 기반 다층 유전체 박막 센서의 특성 분석 (Characteristics Analysis of Total Internal Reflection-based Dielectric Multi-layer Sensor Using Plasmonics Phenomena)

  • 김홍승;이태경;김두근;정유라;오금윤;이병현;기현철;최영완
    • 한국전기전자재료학회논문지
    • /
    • 제25권7호
    • /
    • pp.516-520
    • /
    • 2012
  • In this paper, we have theoretically analyzed and designed a dielectric multi-layer sensor with a SPR (surface plasmon resonance) using analytical calculation and FDTD (finite difference time-domain) methods. The proposed structure is composed of periodic layer and thin metal film. It has many advantages. One of that is a high sensitivity of the SPR. Another is a high Q-factor of the characteristics in the PhC (photonic crystals) micro-cavity structure. The incident light has double resonance characteristics, because the filtered light by PhC structure, dielectric multi-layer, is met the thin metal film for SPR effect. We have also observed the change of resonance characteristics according to the variation of effective index on the metal film.

Multi-point detection of hydrogen using the hetero-core structured optical fiber hydrogen tip sensors and Pseudorandom Noise code correlation reflectometry

  • Hosoki, Ai;Nishiyama, Michiko;Igawa, Hirotaka;Seki, Atsushi;Watanabe, Kazuhiro
    • 동력기계공학회지
    • /
    • 제19권3호
    • /
    • pp.11-15
    • /
    • 2015
  • In this paper, the multi-point hydrogen detection system based on the combination of the hetero-core optical fiber SPR hydrogen tip sensor and interrogator by pseudorandom noise (PN) code correlation reflectometry has been developed. In a light intensity-based experiment with an LED operating at 850 nm, it has been presented that a transmitted loss change of 0.32dB was induced with a response time of 25 s for 4% $H_2$ in $N_2$ in the case of the 25-nm Au, 60-nm $Ta_2O_5$, and 5-nm Pd multi-layers film. The proposed sensor characteristic shows excellent reproducibility in terms of loss level and time response for the in- and out- $H_2$ action. In addition, in the experiment for multi-point hydrogen detection, all sensors show the real-time response for 4% hydrogen adding with reproducible working. As a result, the real-time multi-point hydrogen detection could be realized by means of the combination of interrogating system and hetero-core optical fiber SPR hydrogen tip sensors.