An Analysis of Combustion Characteristics of Residential Facilities through Real Fire Tests in a Small Residential Space (소규모 주거 공간 실물화재실험을 통한 적재 가연물의 연소특성 분석)

  • Yang, So Yeon;Moon, Min Ho;Won, Jeong Hun
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.73-79
    • /
    • 2022
  • In this study, real fire tests were performed on representative combustibles of residential facilities to analyze the fire behavior and combustion characteristics in a small residential space. The considered combustibles were a sofa, a combination of a desk and a chair, and a combination of a mattress and an electric mat. A compartment space fire test was performed using the room corner test equipment prescribed in the KS F ISO 9705 specification. Three real fire tests were conducted by placing the combustible material inside a small compartment with insulation and finishing materials and by igniting the combustible material. Results showed that the peak heat release rate and peak smoke production rate occurred in the combination of the mattress and electric mat. Furthermore, from the result of the fire rate analysis, it was estimated that the fire risk of the mattress and electric mat combination was the highest, followed by the sofa and thedesk and chair combination.

An Experimental Investigation on Combustion Characteristics of the Knockdown Building (조립식 건축물의 화재특성연구)

  • Lee, Jung-Yun;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.30-35
    • /
    • 2008
  • The recent fire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Combustion products including $O_2$, $CO_2$, CO, $NO_x,$, $SO_x$, HCI, HCN were measured, in order to investigate the hazard-reduction effects of employing gas mask protected with filter during the fire emergency of residential container buildings. According to the test results, whether or not employing the filter showed a sheer difference in the toxicity of the fire-induced gases, and then the importance of wearing a gas mask was evidently demonstrated.

A Study on the interior material Combustion Characteristics in residential facilities fire behavior prediction (주거시설 화재성상예측을 위한 내장재 연소특성에 관한 연구)

  • Kim, Gi Hyeon;Kim, Dong Eun;Seo, Dong Goo;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.65-66
    • /
    • 2013
  • As a result of executing Cone Calorimeter experiment on 12 samples among combustibles of domestic residential facilities, flooring materials showed higher HRR and THR than wall papers, and in case of toxicity and SPR, wall papers having adhesive components in one side by considering use conveniences were measured high.

  • PDF

A Study on Fire Behavior of Combustibles in a Residential Building (주택 가연물의 연소 특성에 관한 연구)

  • Lee, Sung-Ryong;Youk, Keun-Hwan
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.25-31
    • /
    • 2009
  • With rapid growths of economy and technology, structures and forms of buildings have been diversified and complicated. Buildings also have become higher and larger than ever before. As a result, more people use a building and more combustibles exist in the building. Without understanding of combustion characteristics and the establishment of a fire safety plan in case of a residential fire, it is expected great loss of lives and properties. In this study, experiments were carried out to promote an understanding of the combustion characteristics of combustibles in the building. Sofa and bed were used as combustibles in the experiment. Heat release rate of the sofa was about 1.9MW. Heat release rate of the bed was approximately 650kW.

A Study on Toxicity Evaluation of Combustion Gases Released from the Residental Container Fire - Efficiency Test for the Fire Gas Mask Filters (주거용 컨테이너 화재시 발생되는 연소가스의 독성 평가에 관한 연구 - 화재용 방독면 filter의 성능평가를 중심으로)

  • Lee Jung Yun;Kim Jeong Hun;Kim Youn-Hi;Jung Ki Chang
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.48-54
    • /
    • 2004
  • The recent Ire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Combustion products including $O_2,\; CO_2,\;CO,\;NOx,\;SOx,\;HCI,\;HCN$ were measured, and blood samples of lab rats were analyzed in terms of Co-Hb, Glucose, AST(GOT), ALT(GPT), in order to investigate the hazard-reduction effects of employing gas mask protected with filter during the fire emergency of residential container buildings. According to the test results, whether or not employing the filter showed a sheer difference in the toxicity of the fire-induced gases, and then the importance of wearing a gas mask was evidently demonstrated.

A Study on the Fire Safety of Residential Facility Considering Grenpel Tower Fire (그렌펠 타워 화재를 고려한 주거시설 화재안전에 관한 연구)

  • Lee, Kyu-Min;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.69-70
    • /
    • 2017
  • Recently, The Building has became high rising and large scaling according to development of economy in domestic and other country, also the building has increased a variety of functions of insulation for warmth. and it has a symbol of economic growth, but it has risk factor for disasters such as fire. this hazards include not only general building but also residential building. Recently, Grenfell Fire that occurred in England has increased in combustion to the 24th floor of the 1st floor for 1 hour. it resulted in 80 deaths and 79 missing persons. In this study we suggest basic data of residential building for fire safety design related to domestic environment to analyze the problem of Grenfell Tower.

  • PDF

A Study on the combustible materials Combustion Characteristics in residential facilities fire behavior prediction (주거시설 화재성상예측을 위한 가연물 연소특성에 관한 연구)

  • Kim, Dong Eun;Kim, Gi Hyeon;Seo, Dong Goo;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.103-104
    • /
    • 2013
  • As a result of experimenting 6 loading combustibles in domestic residential facilities by using Furniture Calorimeter, values of 2,391.26kW were appeared from sofas, 1,891.80kW from drawers, 1,778.95kW from mattress, 1,104kW from chairs, 291kW from tables, and 135.09kW from TV. Also, if applying α value of fire growing rate by classifying fire- growing speeds at NFPA 72 (National Fire Alarm Code 2007, Annex B), mattress can be defined as Ultra-Fast, sofa and drawers Fast, TV Slow, tables Slow, and chairs Medium.

  • PDF

Characteristics of Particulate Atmospheric Polycyclic Aromatic Hydrocarbons Pollution in Residential/Roadside Areas of Metropolitan Cities and a Background Area (대도시의 주거/도로변 지역 및 배경 지역의 대기 중 입자상 다환 방향족 탄화수소의 특성)

  • Jang, Jong-Dae;Shin, Seung-Ho;Jo, Wan-Kuen
    • Journal of Environmental Science International
    • /
    • v.19 no.7
    • /
    • pp.861-869
    • /
    • 2010
  • The present study aims to evaluate the characteristics of atmospheric polycyclic aromatic hydrocarbons (PAHs) pollution in roadside and residential areas of two Korean metropolitan cities (Seoul and Incheon) and a background area (Seokmolee). This purpose was established by analyzing temporal and spacial concentration distribution of total and 7 individual PAHs, which were extracted from ambient particulate matters, and by utilizing a multivariate statistical method (principal component analysis, PCA) for the qualitative determination of potential PAH sources. Target PAHs included benzo(a)anthracene (BaA), benzo(a)pyrene (BaP), benzo(b)fluoranthene (BbF), benzo(k)fluoranthene (BkF), chrysene (Chr), dibenzo(a,h)anthracene (DahA), and indeno(1,2,3-cd)pyrene (IcdP). For all surveyed sites, the concentrations of total PAHs were higher in winter season than in other seasons. However, the concentrations of individual PAHs varied with surveyed sites. In both residential and roadside sites of Seoul and Incheon, BbF revealed the highest atmospheric levels. For all 7 target PAHs, the ambient concentrations were higher in Seoul and Incheon than in a background area (Seokmolee). In both residential and roadside areas, the concentrations of 4 target PAHs (BaA, BbF, BkF, DahA) were higher in Incheon than in Seoul. However, both the residential and roadside Chr concentrations were comparable in Seoul and Incheon. In addition, the residential IcdP concentrations were higher in Incheon than in Seoul, whereas the roadside concentrations were higher in Seoul. The roadside and residential BaP concentrations exhibited the reverse result to the IcdP concentrations. An PCA analysis suggested that atmospheric PAHs in both residential and roadside areas would be due to combined effects of several potential sources such as gasoline- and diesel-fueled vehicles, coal/oil combustion, and waste incineration.

A Study on Feasibility and Applicability of Pneumatic Waste Collection System (쓰레기 수송관로 방식의 적용사례 및 실용에 관한 연구)

  • 민병균;이재영;최상일
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.109-117
    • /
    • 1997
  • The dust chute was a part of equipment in apartment which have been settled down as new residential style in this country since 1960s. However, the dust chute was destructed by results of social discussion, and it ended up old remains which cannot be found in new towns. Nowadays, chute was substituted a collecting system from extra collecting sites which were prepared near residential area. This phenomenon was caused by the poor separating collection. Since the early part of 1995, the whole vocal operating the volume-base charge system has been placed as the institution capable of recycling and separating collection of residential wastes in this country. People pursue the residential quality which is suitable to the Greenround period. Such a diverse effort corresponding to the social change can be also accomplished in the field of waste collecting transportation. In this paper, the local heating system and waste combustion site and hollow are already applied to the new residential area in the form of housing development. After investigating of the waste collecting transportation method in other countries related to such facilities, this paper represents the feasibility and applicability of pneumatic waste collection system which is used practically in the new housing complex and large facilities in other countries.

  • PDF

Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea (II) - Seasonal and Locational Variations (국내 대기 중 독성 휘발성 유기화합물의 오염 특성(II) -계절 및 지역적 변동)

  • 백성옥;김배갑;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.3
    • /
    • pp.207-217
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the second part of the study, the seasonal and locational concentrations of atmospheric VOCs were evaluated. Sampling was conducted seasonally at seven sampling sites. each of them representing a large urban area (commercial and residential), a small urban area (commercial and residential), an industrial area (a site within the complex and a residential), and a background place in Korea. In general, higher concentrations were found in the petro-chemical industrial site than other sites, while VOCs measured in commercial (heavy -traffic) sites were higher than residential sites. Seasonality of VOCs concentrations were not so much clear as other combustion related pollutants such as sulfur dioxide, indicating that the VOCs are emitted from a variety of sources, not only vehicle exhaust and point sources but fugitive emissions. Except the industrial site, the concentrations of VOCs measured in this study do not reveal any serious pollution status, since the levels did not exceed any existing ambient standards in the U.K. and/or Japan. However, the increasing number of petrol -powered vehicles and the rapid industrialization in Korea may result in the increased levels of VOCs concentrations in many large urban areas in the near future, if there is no appropriate programme implemented for the control of these compounds.