• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.036 seconds

Correlation Analysis Between Stenosis and Calcification of Coronary Artery with Using CCTA (CCTA를 이용한 관상동맥 협착과 석회화의 상관관계 분석)

  • Kim, Sang-Jin
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.427-435
    • /
    • 2009
  • We surveyed 586 patients who had been examined CCTA. Out of those patients, 299 (52%) has stenosis of coronary arteries; 166 males (28%) and 133 females (23%). Among them 246 stenosis patients (82.6%) are in 50's to 70's. The number of patients with 50% or more stenosis in more than 1 coronary artery is 299 including 43 males (33.9%) in their 60's and 39 females (37.5%) in their 70's. When a vessel score is higher than 2 points, 70 patients (50.1%) among 139 have 70% or more stenosis; 32 males (39.5%) in their 60's and 27 females (46.6%) in their 70's. It is noted that 14 patients in their 70's show more cases compared to other ages up to 2 or even 5 times when a vessel score is 3 points. LAD shows 77.6% of stenosis, LCX 47.5% and RCA 60.5%. Frequency of a triple vessel disease is high for patients in their 70's; 15 males (36.6%) and 13 females (56.5%) for both. 196 people (33.4%) in the group with stenosis have calcification, while only 40 (6.8%) in the group without stenosis have it. It means that calcification has a significant, if not absolute, correlation with stenosis of coronary arteries.

  • PDF

The Usefulness of Al Face Block Fabrication for Reducing Exposure Dose of Thyroid Glands in Mammography (유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구)

  • Hong, Eun-Ae;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Currently, there are many studies being conducted around the world to reduce exposure dose to radiation for patients to receive medical treatments in a safe environment. We developed and fabricated of this shield that the patients are protected from the radiation and are need of safety control during breast imaging. In this study, for breast imaging, GE Senography 2000D were used and set at SID 65cm, 28kVp, and 63mAs. The measuring instrument was Fluke's Victoreen 6000-529. And we performed Face Block on with 30 patients. The chamber on the actual thyroid glands to take CC and MLO and measure the dosage before and after wearing the Face Block. For the results, after wearing the Face Block, exposure was decreased by 53.8%-100% and 65.8% in average in CC View and by 50%-100% and 60.7% in average in MLO View. The development of the Face Block that practically decreased the exposure dose of thyroid glands, crystalline eyes during breast imaging and reduced the patients' anxiety during breast imaging. The Face Block is expected to improve patients' satisfaction and contribute to reducing patients' exposure dose, but more efforts should be made to reduce exposure dose to medical radiation.

Adjuvant Effect of PAMAM Dendrimer on the Antigenicity of Keyhole Limpet Hemocyanin in Balb/c Mice (Balb/c 마우스에서 Keyhole limpet hemocyanine (KLH)의 항원성에 대한 PAMAM dendrimer 의 면역증강 효과)

  • Lee, Ga-Young;Kim, Min Jee;Kim, So Yeon;Lee, Kyung Bok;Oh, Dong Hyun;Cho, Young Ho;Yoo, Yung Choon
    • Journal of Life Science
    • /
    • v.30 no.10
    • /
    • pp.905-911
    • /
    • 2020
  • The adjuvant effect of PAMAM dendrimer G4 (PAMAM) on the induction of humoral and cellular immune responses against keyhole limpet hemocyanin (KLH) was examined. Mice were immunized subcutaneously twice at two-week intervals with KLH, with or without PAMAM dendrimer (100 ㎍/mouse), and the mice immunized with KLH+PAMAM showed significantly higher antibody titers against KLH than those immunized with KLH alone. The assay for determining the isotypes of the antibodies showed that PAMAM augmented the KLH-specific antibody titers of IgG1, IgG2a, IgG2b, IgG3, and IgM. In addition, mice immunized twice with KLH+PAMAM followed by a subcutaneous injection of KLH (20 ㎍/site) 7 weeks after the primary immunization exhibited a higher delayed-type hypersensitivity (DTH) reaction than those treated with KLH alone. In an in vitro analysis of T lymphocyte proliferation in response to KLH in week 8, the splenocytes of mice treated with KLH+PAMAM showed significantly higher proliferating activity than those treated with KLH alone, and the culture supernatants of cell cultures from mice immunized with added PAMAM dendrimer showed higher levels of KLH-specific cytokine (IL-4 and IFN-r) production. These results suggest that PAMAM dendrimer G4 possesses a potent immune-adjuvant activity for enhancing both humoral and cell-mediated immunity specific to foreign antigens.

Differentiation of Parkinson's Disease and Essential Tremor on I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy- $3{\beta}$-(4-cholorophenyl) tropane) Brain SPECT (파킨슨병과 본태성 진전의 감별진단에서 I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy-$3{\beta}$-(4-cholorophenyl) tropane) 뇌 단일광전자방출 전산화단층촬영의 역할)

  • Pai, Moon-Sun;Choi, Tae-Hyun;Ahn, Sung-Min;Choi, Jai-Yong;Ryu, Won-Gee;Lee, Jae-Hoon;Ryu, Young-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.100-106
    • /
    • 2009
  • Purpose: The study was to assess I-123-N-(3-iodopropen-2-yl)-2[beta]-carbomethoxy-3[beta]-(4-cholorophenyl) tropane(IPT) SPECT in differential diagnosis among early stage of Parkinson's disease(PD) and essential tremor(ET) and normal control(NL) groups quantitatively. Materials and Methods: I-123 IPT brain SPECT of 50 NL, 20 early PD, 30 advanced PD, and 20 ET were performed at 20 minutes and 2 hours. Specific/nonspecific binding of striatum was calculated by using right and left striatal specific to occipital non-specific uptake ratio(striatum-OCC/OCC). Results: Mean value of specific/nonspecific binding ratio was significantly different between advanced PD group and NL group. However, significant overlap of striatal specific/nonspecific binding ratio was observed between PD group and ET group. Bilateral striatal specific/nonspecific binding ratios were decreased in advanced PD. Lateralized differences in the striatal uptake of I-123 IPT correlated with asymmetry in clinical findings in PD group. Conclusion: I-123 IPT SPECT may be a useful method for the diagnosis of PD and objective evaluation of progress of clinical stages. Care should be made in the differential diagnosis of early stage of PD and other motor disturbances mimicking PD such as ET in view of significant overlap in striatal I-123 specific/nonspecific binding ratio.

Radiologic Equipment and Technicians according to the Distribution of the Population (인구 분포에 따른 방사선 장비 및 종사자에 관한 고찰)

  • Yoon, Chul-Ho;Choi, Jun-Gu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.57-65
    • /
    • 2009
  • Purpose: The purpose of this paper is to provide basic data in order to systemize the management of demand and supply of radiologic technicians, to pursue a fair regional distribution of educational institutions, and furthermore to keep reasonable medical treatment and fee. This research was carried out through the investigation of radiologic equipments and technicians according to the distribution of the population. Materials and Methods: We compared and analyzed the correlation between regional population, the number of clinics and hospitals, the number of medical imaging devices, and the number of radiologists and radiologic technicians in 5 cities without "Gu" administrative units in 2008. Results: 27,317 radiologic technicians have been produced since the administration of the national qualifying exam for radiologic technicians. About 18,000 radiologic technicians are currently working. There are 39 colleges or universities with Departments of Radiology and the admission quota is 2,120 students excluding one college. The ratio of radiologic equipments to radiologic technicians is 2.6 to 1. Conclusion: There is a dilemma in which some radiologic technicians fail to find appropriate jobs while some clinics or hospitals are in need of radiologic technicians. This dilemma is due to unreasonable regional discrepancies in pay system and welfare situation, and excessive profit-oriented recruiting system of clinics and hospitals. The increase of students of Radiologic Departments and approval of additional departments will end up with producing superfluous high academic degree holders, which is on the contrary to the government policy to produce more job opportunities. So the policy of increasing Radiologic Departments should be reconsidered.

  • PDF

A Study on Various Automatic Exposure Control System in Multi-Detector Computed Tomography by Using Human Phantom (인체 모형을 이용한 다중 검출기 컴퓨터단층촬영기기의 다양한 자동노출제어 시스템에 대한 연구)

  • Kim, Yong-Ok;Seoung, Youl-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1714-1720
    • /
    • 2012
  • The purpose of the study was to evaluation of the radiation dose reduction and the possibility of the maintainability of the adequate image quality using various automatic exposure control (AEC) systems in multi-detector computed tomography (MDCT). We used three AEC systems for the study: General Electric Healthcare (Auto-mA 3D), Philips Medical systems (DoseRight) and Siemens Medical Solutions (Care Dose 4D). The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using human phantom. The image quality of the phantom was evaluated with measuring the image noise (standard deviation) by insert regions of interests. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the Auto-mA 3D, 58.2% in the DoseRight, and 48.6% in the Care Dose 4D. And, there was not statistical significant difference among the image quality in the Strong/Weak of the Care Dose 4D(P=.269). This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

A Convergence Study of age-related Bone Loss and Peak BMD in Korean (한국인에서 연령에 따른 요추 및 대퇴부에서의 최대 골밀도 및 골소실률에 관한 융합 연구)

  • Kim, Young-Ran;Park, Chang-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.5
    • /
    • pp.77-83
    • /
    • 2018
  • We investigated the age-related BMD, accumulated bone loss rate and peak BMD at Lumbar spine, total hip in Korean using data from KNHANES (the 1st(2010), 2nd(2011) and year at the 5th survey). We found that the cubic regression model was the best for describing age-related changes in BMD. Lumbar spine, total hip in bone mineral density difference were analyzed using ANOVA. This showed that the peak BMD was at the age of 20-24 years at lumbar spine, total hip and the bone loss rate was the highest in the lumbar spine at 75-79 years and the total hip was 80 years or older in the men. This showed that the peak BMD was at the age of 40-44 years at lumbar spine, total hip and the bone loss rate was the highest in the lumbar spine at 70 years or older and the total hip was 75-79 years older, 80 years old, 55-59 years old in the women. Therefore, in men, 75 years or older to increase the rate of osteoporosis screening, and women in their 50s and older menopause related management strategies to manage osteoporosis will be needed.

Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application (의료용 방사성폐기물 자체처분을 위한 방사능 측정 및 평가)

  • Kim, Changbum;Park, MinSeok;Kim, Gi-Sub;Jung, Haijo;Jang, Seongjoo
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • The amounts of radioactive wastes to be disposed in the medical institute have been increased due to development of radiation diagnosis and therapy rapidly. They are produced mostly by the very short lived radioisotopes such as $^{18}F$ used in PET/CT, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}Tl$, etc. IAEA proposed a criteria for the clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). Radioactive wastes of $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}TI$ in the several types of container like Marinelli beaker, vial and plastic, were collected to measure the concentration of the waste of each nuclide in accordance with IAEA criteria. The measurement method and procedure of determining specific activity of the wastes using gamma emitters like MCA, gamma counter and beta emitters were developed. For the efficiency calibration of the detectors, CRM (certified reference material) which has the same dimension and shape was provided by Korea Research Institute of Standards and Science (KRISS). Correction factor of the radioactivity decay was calculated based on the measurement results, and the consideration of mutual relation with theoretical equation. The result of this study will be proposed as ISO standard.

Morphological Analysis of the Sinus Lateral Wall Using Cone-Beam Computed Tomography (콘빔형 전산화단층영상을 이용한 상악동 측벽의 형태학적 분석)

  • An, Seo-Young;Kim, Yong-Gun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.349-357
    • /
    • 2012
  • The purpose of this study was to measure the thickness of the sinus lateral wall using cone-beam computed tomography (CBCT), and to find the most suitable vertical position for lateral window opening prior to sinus elevation. Fifty three patients requiring sinus elevation had CBCT scans acquired by CB MercuRay (Hitachi, Medico, Tokyo, Japan) from July, 2010 to June, 2012. The thickness of the sinus lateral wall was measured according to its vertical position against the sinus inferior border (SIB), and its mean was calculated through two repeated measurements. The thickness of the sinus lateral wall was more than 2 mm at 2 mm above the sinus inferior border (SIB+2), however, it was less than 2 mm at 3 mm above the sinus inferior border (SIB+3). In conclusion, it is recommended that the inferior border of lateral wall window be made 3 mm above the sinus inferior border during sinus elevation using the lateral approach considering the thickness of the sinus lateral wall.

Prevalence and Risk Factors of the Gallbladder Polyps Diagnosed by Ultrasound (복부초음파검사로 진단된 담낭용종의 유병률과 위험인자 분석)

  • LEE, Mi-Hwa;Cho, Pyong-Kon;Kwon, Duck-Moon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.127-134
    • /
    • 2015
  • This study was designed to determine the prevalence of gallstones in the last three years and evaluate the associated risk factors in the population who underwent health screening. Although there are many studies reporting the prevalence and risk factors of GB polyp, the results varied among each report. The aims of this study were to evaluate the prevalence rate and risk factors of GB polyp, colon polyp and fatty liver in the population who underwent health screening. The study population consisted of 4,877 visited the health promotion center in Dalseogu, Daegu in Korea from January 2011 to December 2013. Each participant in the study had their biliary system gallbladder examined using ultrasonography. The prevalence of GB polyp was evaluated along with age, gender, metabolic syndrom, body mass index (BMI), Fatty liver, Colon polyp. A showed of total 383 (7.9%) people were found to have GB polyps. The prevalence of sex among 256 (9.8%) patients men and 127 (5.6%) women which showed significantly higher in male than in female subjects(p=0.001). The mean size of the GB polyps 4.92 mm (1.6-17 mm). The sizes of most GB polyps (73.6%) were less than 10 mm in diameter. 122 subjects (31.28%) had multiple GB polyps which 2 or more polyps and 261 subjects (68.2%) had single polyp. Independent risk factors related with GB polyp were male gender (OR 0.551, p<0.001), overweight that BMI above $23kg/m^2$ (OR 0.713, p=0.002) triglyceride (OR 0.571, P<0.001), metabolic syndrome (OR 0.049, p=0.033) and colon polyp (OR 1.409, p=0.002). In spite of the conclusion, the prevalence GB polyp was higher than previous Korea and other country reports. The GB polyp in a healthy population was results as 7.9%. The risk factors of GB polyps were found to be male, being overweight, triglyceride, metabolic syndrome and colon polyp. Not only the subject of a health examination is needed but, a further study of the general public when possible.