Browse > Article
http://dx.doi.org/10.14316/pmp.2014.25.1.8

Measurement and Estimation for the Clearance of Radioactive Waste Contaminated with Radioisotopes for Medical Application  

Kim, Changbum (Department of Radiation Application Safety Evaluation, Korea Institute of Nuclear Safety)
Park, MinSeok (Radiation Safety and Section, Korea Institute of Radiological and Medical Sciences)
Kim, Gi-Sub (Radiation Safety and Section, Korea Institute of Radiological and Medical Sciences)
Jung, Haijo (Radiation Safety and Section, Korea Institute of Radiological and Medical Sciences)
Jang, Seongjoo (Department of Radiology, Dongshin University)
Publication Information
Progress in Medical Physics / v.25, no.1, 2014 , pp. 8-14 More about this Journal
Abstract
The amounts of radioactive wastes to be disposed in the medical institute have been increased due to development of radiation diagnosis and therapy rapidly. They are produced mostly by the very short lived radioisotopes such as $^{18}F$ used in PET/CT, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}Tl$, etc. IAEA proposed a criteria for the clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). Radioactive wastes of $^{18}F$, $^{99m}Tc$, $^{123}I$, $^{125}I$ and $^{201}TI$ in the several types of container like Marinelli beaker, vial and plastic, were collected to measure the concentration of the waste of each nuclide in accordance with IAEA criteria. The measurement method and procedure of determining specific activity of the wastes using gamma emitters like MCA, gamma counter and beta emitters were developed. For the efficiency calibration of the detectors, CRM (certified reference material) which has the same dimension and shape was provided by Korea Research Institute of Standards and Science (KRISS). Correction factor of the radioactivity decay was calculated based on the measurement results, and the consideration of mutual relation with theoretical equation. The result of this study will be proposed as ISO standard.
Keywords
Radioactive waste; Self disposal; Medical radioactive isotope; Specific radioactivity;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Park JK, Kim SK, et al: Enhancement of the Early/Precise Diagnosis Based on the Measurement of SUVs in F-18 FDG PET/CT Whole-body Image. J Korean J Med Phys 24(3): 176-182 (2013)
2 Kim SJ, Han EO: Changes in External Radiation Dose Rate for PET-CT Test Patients. J Radiation Protection 37(2):103-107 (2012)
3 Shapito J: Radiation Protection: A guide for scientists, regulator and Physicians, 4th ed, Harvard University Press (2002), pp. 359-371
4 IAEA Safety Series No.40: Applying Radiation Safety Standards in Nuclear Medicine (2005)
5 Ravichandran R, Binukumar JP, Sreeram R, Arunkumar LS: An overview of radioactive waste disposal procedures of a nuclear medicine J Med Phys 36(2):95-99 (2011)   DOI   ScienceOn
6 IAEA Safety Series No.111: Classification of Radioactive Waste (1994)
7 IAEA TECDOC-1183: Management of radioactive waste from the use of radionuclides in medicine (2000)
8 IAEA Safety Series No.111-P-1.1: Application of exemption principles to the recycle and reuse of materials from nuclear facilities (1992)
9 IAEA Safety Guide RS-G-1.7: Application of the concepts of exclusion, exemption and clearance (2004)
10 http://www.nssc.go.kr/nssc/information/law4_4.jsp, The code of nuclear safety and security commission Jae2012-59Ho: Regulation for the clearance of radioactive waste (2012)