• Title/Summary/Keyword: RS485 Communication

Search Result 109, Processing Time 0.023 seconds

Design and Implementation of Real-Time Management System for Efficient Operation of Motor Control Center (모터제어센터의 효율적인 운영을 위한 실시간 관리 시스템의 설계 및 구현)

  • Lee, Tae-Oh
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.2
    • /
    • pp.247-253
    • /
    • 2008
  • In this paper, we describes the design and implementation of real-time management system for efficient operation via monitoring and control of MCC(Motor Control Center). The real-tine management system can be divided hardware(MCC panel) and software(management program). First, hardware is divided into load attaching motor and MCC components for working together control and data network. Second, software(management system) are consisted of communication interface, environment setting, data processing modules. The produced and implemented reduction model of MCC panel is pretested using m-PRO, iM-PRO devices, and HyperTerminal. For field test, MCC panel is tested by RS-232C/485, communication procedure in management system is certified by transmitting and receiving message using control command. By the experimental results, the implemented real-time management system can be used to operate MCC system.

A Development of Energy Saving System for Automatic Lighting Control using PIR (PIR을 이용한 에너지절감형 자동조명제어 시스템 개발)

  • Joo, Jin-Hwan;Kang, Shin-Wook;Kwon, Hak-Cheol;Lee, Suk-Gyu;Park, Ju-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.58-68
    • /
    • 2010
  • This paper proposes a novel design of auto light control system with high efficiency using RS-485 to save lighting energy in new and existing buildings. The proposed system consists of ALSU(Auto Light Sensor Unit) which is connected with RS-485 to control lighting appliances, ALS(Auto Light Unit), and Hi-FACS which is a monitoring system using communication interface. lighting appliances are automatically controlled by ALSU which detects moving objects. The total system is designed to be controlled by either manual or auto mode by using the ALS. In addition, the monitoring system receives the information on the state of the lighting appliances from ALSU and ALS to control the proposed system We compared the proposed system with the conventional one in functionality and energy saving point of view. Through some experimental results, the proposed system shows better performance in various circumstances.

Development of a Monitoring System for a Pipe Cleaning Robot with RS-485 (RS-485 통신을 이용한 배관청소 로봇의 모니터링 시스템 개발)

  • Kim, Min-wook;Lee, Hun-seok;Oh, Jin-seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.5
    • /
    • pp.923-930
    • /
    • 2016
  • Various pipes are used in the many industrial field such as water supply, drainage system and marine plants, so a maintenance of these pipes is essential. Especially, the maintenance of the piping in the industrial field, some professional staffs enter and clean the pipe. If the professional staffs can not enter and clean the pipe, the workers has to use the method of inserting a scraper connected to wire inside the pipe. However, this method demands huge budget and causes a number of problems such as traffic congestion. To solve these problems, pipe cleaning robot has been researching and developing. Many Pipe cleaning robots have a problem, that is impossible to confirm the operating condition of the robot in a real time. This paper suggest pipe cleaning robot with RS-485 which transmit operating and cleaning condition of robot and inner pipe filmed by camera, that user can check.

MCU Module Design for Smart Farm Sensor Processing (스마트팜 센서 처리용 MCU 모듈 설계)

  • Kim, Gwan-hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.285-286
    • /
    • 2021
  • With the recent development of Internet of Things (IoT) technology, smartization technology is expanding to the fields of agriculture, livestock, and fisheries, and smartization is in progress. In this smart technology, the most important thing is how to measure the data in the field and transmit it to the management system. Currently, the sensors used in the construction of smart farms and other livestock houses and farms are measuring and monitoring smart farms and other environmental conditions through various sensors such as temperature, humidity, CO gas, CO2, hydrogen, and O2. The communication method between these sensors and the HMI (Human Machine Interface) module that controls and manages the smart farm is still mainly using the RS-485-based modbus-RTU method. In this paper, we intend to design the MCU module for HMI so that various sensor modules can be connected to manage data through the RS-485-based Modbus method so that the sensor data required for smart farm construction can be managed by the HMI module.

  • PDF

Development of the Serial Data Transmission System for Pneumatic Valve System Control

  • Kim, Dong-Soo;Choi, Byung-Oh;Seo, Hyun-Seok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1152-1156
    • /
    • 2003
  • For pneumatic valve system control, we need a serial data transmission system with high speed and reliability for information interchange between main computer and I/O devices. This paper presents a set of design techniques for a data communication system that is mainly used for pneumatic valve system control. For this purpose, we first designed hardware modules for an interface between central control module and local node that handles the operation of solenoid control valves. in addition, we developed a communication protocol for construction of rs-485 based multi-drop network and this protocol is basically designed with a kind of polling technique. Finally we evaluated performance of the developed system. the field test results show that, even under high noise environment, the data transmission of 375kbps rate is possible up to 1,500meter without using repeater. In addition, the system developed in this research is easily to be extended for a communication network because of its modular structure.

  • PDF

An Industrial monitoring board design with support for multiple communications (다양한 통신을 지원하는 산업용 모니터링 보드 설계)

  • Eum, Sang-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.197-199
    • /
    • 2018
  • Recently, many industrial instruments face the problem of protocol compatibility with the external monitoring and control system. This paper is prepared in the main control board to support the industrial communication protocol conversion, control, and monitoring. The industrial communication gateway module is also designed to ensure that the protocol conversion of CAN bus and Ethernet. The main board processor is used the Atmega2560, and placed 4ea RS485 serial slots for sub-board. One of them is used for communication CAN bus and Ethernet. It provides analog and digital I / O through each of the slots is used for control and monitoring.

  • PDF

An Implementation of System for Control of Dissolved Oxygen and Temperature in the pools of Smart Fish Farm (스마트 양식장 수조 내 용존 산소 및 온도 제어를 위한 시스템 구현)

  • Jeon, Joo-Hyeon;Lee, Yoon-Ho;Lee, Na-Eun;Joo, Moon G.
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.16 no.6
    • /
    • pp.299-305
    • /
    • 2021
  • Dissolved oxygen, pH, and temperature are the most important factors for fish farming because they affect fish growth and mass mortality of the fish. Therefore, fish farm workers must always check all pools on the farm, but this is very difficult in reality. That's why we developed a control system for smart fish farms. This system includes a gateway, sensor gatherers, and a PC program using LabVIEW. One sensor gatherer can cover up to four pools. The sensor gatherers are connected to the gateway in the form of a bus. For the gateway, the ATmega2560 is used as the main processor for communication and the STM32F429 is used as a sub-processor for displaying LCD. For the sensor gatherer, ATmega2560 is used as the main processor for communication. MQTT (Message Queuing Telemetry Transport), RS-485, and Zigbee are used as the communication protocols in the control system. The users can control the temperature and the dissolved oxygen using the PC program. The commands are transferred from the PC program to the gateway through the MQTT protocol. When the gateway gets the commands, it transfers the commands to the appropriate sensor gatherer through RS-485 and Zigbee.

Design and Implementation of Progress Management System Using Swing Component Based on Internet (Swing 컴포넌트를 이용한 인터넷 기반 공정관리시스템 설계와 구현)

  • Kim, Tai-Suk;Kim, Jong-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.8
    • /
    • pp.1163-1170
    • /
    • 2010
  • In this paper, in order to develop a remote progress management system through the Internet, we show a design method to make easy maintenance by developing the system with both the JAVA language and GoF Design Patterns. For the system implementation, we added the RS232C and RS422/RS485 communication modules to PLC(Programmable Logic Controller) in the control box which provide the real time status data of machines. Also we set up the RS232C to Ethernet converter based on wireless environment to communicate the PLC control data. We use JAVA Swing components to implement the multi-tier architecture system supported the GUI of the Applet and Frame at the same time so that the manager grasps the progress of work easily at the remote machines through the Internet. The key objective of the multi-tier architecture is to share resources among clients, this proposed system can help to develop the software to control the remote machine, and also it has the advantage that developer who wants to make a similar software can make easy to add new function reusing the existing codes.

Development of the Intelligent Multi-Casting System (지능형 멀티 캐스팅 방송 시스템의 개발)

  • Lim Chan-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.10 no.4
    • /
    • pp.90-96
    • /
    • 2005
  • This paper develops a multi-casting system could be used in a school and hospital and government and municipal public offices. The developed multi-casting system uses various educational multimedia titles effectively and is capable of remote control by using a network(LAN). The developed system includes speaker control module that make individual or group broadcasting, AV contents control module for using a diverse educational multimedia title effectively and light control module. The system uses RS-485C communication module and the effective control system interface based on GUI.

  • PDF

Design of EUT test equipment for EMC Testing (EMC 시험을 위한 EUT 시험장비 설계)

  • Hong-Rak Kim;Youn-Jin Kim;Seong-Ho Park;Man-Hee Lee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.35-40
    • /
    • 2023
  • For the EMC test, the radiation characteristics and immunity characteristics of the EUT are measured under the condition that the EUT maintains its normal operation. For normal operation of the EUT, it is necessary to operate the EUT and monitor its status through separate equipment outside the anechoic chamber. External equipment operates and monitors the EUT through various communications such as 1553B communication, RS-485 communication, and Ethernet communication. At this time, external equipment can transmit noise through the communication line. This noise is transmitted to the LISN through the connected power cable and measured. It is also radiated through the connection terminal to the LISN. In this case, the communication line is the power line It should be designed so that noise is not transmitted through electromagnetic isolation as much as possible. In addition, noise from external equipment must be suppressed as much as possible from entering the chamber through the communication line. In this paper, external EUT test equipment applied for EMC test It explains the considerations in the design and manufacture of the design and explains the satisfaction of the design through tests including CE and RE.