• Title/Summary/Keyword: RMS error

Search Result 393, Processing Time 0.025 seconds

Measurement Procedure and Analysis of Terrestrial DTV Field Test in Taejeon (대전지역의 지상파 DTV 현장 측정 및 결과 분석)

  • 김종호;조진호;이형수;박재홍
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.830-838
    • /
    • 2000
  • This paper represents measurement prodcedure and analysis of terrestrial DTV field test results over Taejeon city area. Thirty three points were selected as measuring points. Signal power, noise power, Segment Error Rate, RMS delay spread and equalizer performance was measured. The video and audio quality of DTV was good over half of test sites. Equalizer, could correct signal ghost and improve S/N up to 13.7 dB. From this test, the test procedure for DTV will be estabilished.

  • PDF

Deconvolution Based on the Reconstruction of Residue Polynomials (나머지 다정식의 재구성에 의한 디컨볼루션)

  • 유수현;김재구
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.6
    • /
    • pp.19-27
    • /
    • 1985
  • In most engineering problems the output of linear system could be expressed by a con-volution of finite input and impulse response. In this paper, the deconvolution algorithm based on the reconstruction of residue polynomials to get a convolution factor, impvlse response or system input, were considered. Two techniques, using a matrix and Euclid's algorithm were discussed. In the illustrated examples, the result showed high accuracy about 10-10 RMS error.

  • PDF

Technique of Measuring Wind Speed and Direction by Using a Roll-rotating Three-Axis Ultrasonic Anemometer (II) (롤 회전하는 3축 초음파 풍속계를 활용한 풍향 풍속 측정기법(II))

  • Chang, Byeong Hee;Lee, Seunghoon;Kim, Yang won
    • Journal of Wind Energy
    • /
    • v.9 no.4
    • /
    • pp.9-15
    • /
    • 2018
  • In a previous study, a technique for measuring wind speed and direction by using a roll-rotating three-axis ultrasonic anemometer was proposed and verified by wind tunnel tests. In the tests, instead of a roll sensor, roll angle was trimmed to make no up flow in the transformed wind speeds. Verification was done in point of the residual error of the rotation effect treatment. In this study, roll angle was measured from the roll motor encoder and the transformed wind speed and direction on the test section axis were compared with the ones provided to the test section. As a result, up to yaw $20^{\circ}$ at a wind speed of 12 m/sec or over, the RMS error of wind speed was within the double of the ultrasonic anemometer error. But at yaw $30^{\circ}$, it was over the double of the ultrasonic anemometer error. Regardless of wind speed, at yaw $20^{\circ}$ and $30^{\circ}$, the direction error was within the double of the ultrasonic anemometer error. But at yaw $10^{\circ}$ or less, it was within the error of the ultrasonic anemometer itself. This is a very favorable characteristic to be used for wind turbine yaw control.

Convergence rates of the TE EFIE scattering solutions from a PEC cylinder (PEC 원통을 TE EFIE 방법으로 산란 해석한 결과의 수렴율)

  • Hong, Chinsoo;Bae, HyungChul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7189-7195
    • /
    • 2015
  • The method of moments (MoM) is implemented to simulate scattering from a PEC (perfectly electric conductor) cylinder in the TE(transversw electric) EFIE (Electric Field Integral Equation) approach. The procedure expresses the singularity integral and the hypersingularity integral in terms of an analytic function and employs a singularity isolation process coupled with numerical technique along the discretized segment to evaluate the self terms. It is known that, in the MoM technique, the choice of base functions and test functions is very important for the accuracy and convergence of the numerical analysis. Thus, in this paper, three conditions, obtained from the combination of basis functions and test functions, are adopted to get the induced currents on the PEC surface. These currents are compared to the analytical one in the relative rms current error to get the condition that shows fast convergence rate. The fast order of convergence of the current error, 2.528, is obtained under the combination of pulse basis function/delta test function.

Accuracy Analysis of 2-D Direction Finding Based on Phase Comparison (위상비교 방식을 이용한 2차원 방향탐지 정확도 분석)

  • Chae, Myoung-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.8
    • /
    • pp.653-660
    • /
    • 2017
  • In this paper, the author analyzes direction finding accuracy based on phase comparisons to estimate elevation and azimuth angles of arrival signals. This paper considers the uniform array configurations using four and three elements. In that direction finding structures, I present the analytic expressions for estimated elevation and azimuth angles and then analyze the direction finding errors. And one presents the design guideline of direction finding system in comparison with aspects of accuracy, structure, the number of channels in that structures. The analysis result is similar with simulation one and has difference within $1.2^{\circ}RMS$. From the proposed analysis results, one knows that when SNR is 20 dB and the baseline is half of wavelength, the estimated elevation accuracy of the uniform array using four elements is 1.15 times better than the one of the uniform array using three elements and the estimated azimuth accuracy is same each other. In addition, one knows coning error is eliminated in 2-D direction finding structure.

A Study on Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-phase Grid-connected Inverters (단상 계통연계형 인버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구)

  • Hwang, Seon-Hwan;Hwang, Young-Gi;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.68-76
    • /
    • 2014
  • This paper presents an offset error compensation algorithm for the accurate phase angle of the grid voltage in single-phase grid-connected inverters. The offset error generated from the grid voltage measurement process cause the fundamental harmonic component with grid frequency in the synchronous reference frame phase lock loop (PLL). As a result, the grid angle is distorted and the power quality in power systems is degraded. In addition, the dq-axis currents in the synchronous reference frame and phase current have the dc component, first and second order ripples compared with the grid frequency under the distorted grid angle. In this paper, the effects of the offset and scaling errors are analyzed based on the synchronous reference frame PLL. Particularly, the offset error can be estimated from the integrator output of the synchronous reference frame PLL and compensated by using proportional-integral controller. Moreover, the RMS (Root Mean Square) function is proposed to detect the offset error component. The effectiveness of the proposed algorithm is verified through simulation and experiment results.

Nonlinear Damper Model for the Quantification of joint Mechanical Properties (관절계 역학적 특성의 정량화를 위한 비선형 댐퍼모델)

  • EOM Gwang-Moon;LEE Chang-Han;KIM Chul-Seung;Heo Ji-Un
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.188-193
    • /
    • 2005
  • The purpose of this paper is to develop a more precise damper model of the joint for the quantification of the joint mechanical properties. We modified the linear damper model of a knee joint model to nonlinear one. The normalized RMS errors between the simulated and measured joint angle trajectories during passive pendulum test became smaller with the nonlinear damper model than those of the linear one which indicates the nonlinear damper model is better in precision and accuracy. The error between the experimental and simulated knee joint moment also reduced with the nonlinear damper model. The reduction in both the trajectory error and the moment error was significant at the latter part of the pendulum test where the joint angular velocity was small. The nonlinearity of the damper was significantly greater at thin subject group and this indicates the nonlinearity is a useful index of joint mechanical properties.

Times Series Analysis of GPS Receiver Clock Errors to Improve the Absolute Positioning Accuracy

  • Bae, Tae-Suk;Kwon, Jay-Hyoun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.6_1
    • /
    • pp.537-543
    • /
    • 2007
  • Since the GPS absolute positioning with pseudorange measurements can significantly be affected by the observation error, the time series analysis of the GPS receiver clock errors was performed in this study. From the estimated receiver clock errors, the time series model is generated, and constrained back in the absolute positioning process. One of the CORS (Continuously Operating Reference Stations) network is used to analyze the behavior of the receiver clock. The dominant part of the model is the linear trend during 24 hours, and the seasonal component is also estimated. After constraining the modeled receiver clock errors, the estimated position error compared to the published coordinates is improved from ${\pm}11.4\;m\;to\;{\pm}9.5\;m$ in 3D RMS.

Identification of guideway errors in the end milling machine using geometric adaptive control algorithm (기하학적 적응제어에 의한 엔드밀링머시인의 안내면 오차 규명)

  • 정성종;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.1
    • /
    • pp.163-172
    • /
    • 1988
  • An off-line Geometric Adaptive Control Scheme is applied to the milling machine to identify its guideway errors. In the milling process, the workpiece fixed on the bed travels along the guideway while the tool and spindle system is fixed onto the machine. The scheme is based on the exponential smoothing of post-process measurements of relative machining errors due to the tool, workpiece and bed deflections. The guideway error identification system consists of a gap sensor, a, not necessarily accurate, straightedge, and the numerical control unit. Without a priori knowledge of the variations of the cutting parameters, the time-varying parameters are also estimated by an exponentially weighted recursive least squares method. Experimental results show that the guideway error is well identified within the range of RMS values of geometric error changes between machining passes disregarding the machining conditions.

Effect of abutment superimposition process of dental model scanner on final virtual model (치과용 모형 스캐너의 지대치 중첩 과정이 최종 가상 모형에 미치는 영향)

  • Yu, Beom-Young;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.203-210
    • /
    • 2019
  • Purpose: The purpose of this study was to verify the effect of the abutment superimposition process on the final virtual model in the scanning process of single and 3-units bridge model using a dental model scanner. Materials and methods: A gypsum model for single and 3-unit bridges was manufactured for evaluating. And working casts with removable dies were made using Pindex system. A dental model scanner (3Shape E1 scanner) was used to obtain CAD reference model (CRM) and CAD test model (CTM). The CRM was scanned without removing after dividing the abutments in the working cast. Then, CTM was scanned with separated from the divided abutments and superimposed on the CRM (n=20). Finally, three-dimensional analysis software (Geomagic control X) was used to analyze the root mean square (RMS) and Mann-Whitney U test was used for statistical analysis (${\alpha}=.05$). Results: The RMS mean abutment for single full crown preparation was $10.93{\mu}m$ and the RMS average abutment for 3 unit bridge preparation was $6.9{\mu}m$. The RMS mean of the two groups showed statistically significant differences (P<.001). In addition, errors of positive and negative of two groups averaged $9.83{\mu}m$, $-6.79{\mu}m$ and 3-units bridge abutment $6.22{\mu}m$, $-3.3{\mu}m$, respectively. The mean values of the errors of positive and negative of two groups were all statistically significantly lower in 3-unit bridge abutments (P<.001). Conclusion: Although the number of abutments increased during the scan process of the working cast with removable dies, the error due to the superimposition of abutments did not increase. There was also a significantly higher error in single abutments, but within the range of clinically acceptable scan accuracy.