• Title/Summary/Keyword: Pull up

Search Result 258, Processing Time 0.023 seconds

Resisting Behavior of Fully-Grouted Rock Bolts with Compressible Spacers (압축성 간격재를 설치한 전면접착식 볼트의 인발저항 거동)

  • Hwang, Yong-Sub;Lee, Sang-Duk
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.377-385
    • /
    • 2011
  • In order to prove the applicability of rock bolts with compressible spacers, laboratory model tests and large scale model tests were conducted. Laboratory model tests were performed in various distance of compressible spacers to determine the optimal distance of compressible spacers. The optimal distance of compressible spacers was found that is 1/4 of rock bolts unit length. Large scale model tests that the size was 0.6 m (diameter) ${\times}$ 4.45 m (length) were conducted. Test results showed that pull out resistance could be increased up to 15% larger than that of unused case by using compressible spacers.

Seismic performance of steel plate shear walls with variable column flexural stiffness

  • Curkovic, Ivan;Skejic, Davor;Dzeba, Ivica
    • Steel and Composite Structures
    • /
    • v.33 no.1
    • /
    • pp.1-18
    • /
    • 2019
  • In the present study, the behavior of steel plate shear walls (SPSW) with variable column flexural stiffness is experimentally and numerically investigated. Altogether six one-bay one-story specimens, three moment resisting frames (MRFs) and three SPSWs, were designed, fabricated and tested. Column flexural stiffness of the first specimen pair (one MRF and one SPSW) corresponded to the value required by the design codes, while for the second and third pair it was reduced by 18% and 36%, respectively. The quasi-static cyclic test result indicate that SPSW with reduced column flexural stiffness have satisfactory performance up to 4% story drift ratio, allow development of the tension field over the entire infill panel, and cause negligible column "pull-in" deformation which indicates that prescribed minimal column flexural stiffness value, according to AISC 341-10, might be conservative. In addition, finite element (FE) pushover simulations using shell elements were developed. Such FE models can predict SPSW cyclic behavior reasonably well and can be used to conduct numerical parametric analyses. It should be mentioned that these FE models were not able to reproduce column "pull-in" deformation indicating the need for further development of FE simulations with cyclic load introduction which will be part of another paper.

Design of Low-Area 1-kb PMOS Antifuse-Type OTP IP (저면적 1-kb PMOS Antifuse-Type OTP IP 설계)

  • Lee, Cheon-Hyo;Jang, Ji-Hye;Kang, Min-Cheol;Lee, Byung-June;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.9
    • /
    • pp.1858-1864
    • /
    • 2009
  • In this paper, we design a non-volatile memory IP, 1-kb one-time programmable (OTP) memory, used for power management ICs. Since a conventional OTP cell uses an isolated NMOS transistor as an antifuse, there is an advantage of it big cell size with the BCD process. We use, therefore, a PMOS transistor as an antifuse in lieu of the isolated NMOS transistor and minimize the cell size by optimizing the size of a OTP cell transistor. And we add an ESD protection circuit to the OTP core circuit to prevent an arbitrary cell from being programmed by a high voltage between the terminals of the PMOS antifuse when the ESD test is done. Furthermore, we propose a method of turning on a PMOS pull-up transistor of high impedance to eliminate a gate coupling noise in reading a non-programmed cell. The layout size of the designed 1-kb PMOS-type antifuse OTP IP with Dongbu's $0.18{\mu}m$ BCD is $129.93{\times}452.26{\mu}m^2$.

Design of High-Reliability Differential Paired eFuse OTP Memory for Power ICs (Power IC용 고신뢰성 Differential Paired eFuse OTP 메모리 설계)

  • Park, Young-Bae;Jin, Li-Yan;Choi, In-Hwa;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.2
    • /
    • pp.405-413
    • /
    • 2013
  • In this paper, a high-reliability differential paired 24-bit eFuse OTP memory with program-verify-read mode for PMICs is designed. In the proposed program-verify-read mode, the eFuse OTP memory can do a sensing margin test with a variable pull-up load in consideration of programmed eFuse resistance variation and can output a comparison result through a PFb (pass fail bar) pin by comparing a programmed datum with its read one. It is verified by simulation results that the sensing resistance is lower with $4k{\Omega}$ in case of the designed differential paired eFuse OTP memory than $50k{\Omega}$ in case of its dual-port eFuse OTP memory.

Design of High-Reliability eFuse OTP Memory for PMICs (PMIC용 고신뢰성 eFuse OTP 메모리 설계)

  • Yang, Huiling;Choi, In-Wha;Jang, Ji-Hye;Jin, Liyan;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1455-1462
    • /
    • 2012
  • In this paper, a BCD process based high-reliability 24-bit dual-port eFuse OTP Memory for PMICs is designed. We propose a comparison circuit at program-verify-read mode to test that the program datum is correct by using a dynamic pseudo NMOS logic circuit. The comparison result of the program datum with its read datum is outputted to PFb (pass fail bar) pin. Thus, the normal operation of the designed OTP memory can be verified easily by checking the PFb pin. Also we propose a sensing margin test circuit with a variable pull-up load out of consideration for resistance variations of programmed eFuse at program-verify-read mode. We design a 24-bit eFuse OTP memory which uses Magnachip's $0.35{\mu}m$ BCD process, and the layout size is $289.9{\mu}m{\times}163.65{\mu}m$ ($=0.0475mm^2$).

Experiences of thoracic esophagectomy with laparoscopic gastric pull up in thoracic esophageal cancer patient in single center

  • Jun, Jin-Woo;Kim, Wooshik;Park, Jong-Min
    • Korean Journal of Clinical Oncology
    • /
    • v.14 no.2
    • /
    • pp.95-101
    • /
    • 2018
  • Purpose: The standard treatment of esophageal cancer is the Ivor-Lewis operation, which consists of an abdominal phase involving gastric tube formation, and a chest phase involving esophagectomy and anastomosis. We aimed to report our experience of performing thoracic esophagectomy with the laparoscopic gastric pull up (LGPU) technique and its surgical outcomes. Methods: Clinicopathologic data and short-term surgical outcomes of 14 patients who underwent LGPU for thoracic esophageal cancer from August 2008 to May 2016 were retrospectively reviewed. Results: Mean age of the patients was 62.3 years and mean body mass index was $21.7kg/m^2$. Eleven patients had medical comorbidities. Patients' mean American Society of Anesthesiologists score was 2. Mean operation time was 428.5 minutes, with the mean abdominal operation time being 138.9 minutes. There was no open conversion case. Three patients had pneumonia, three patients had surgical site infection, and one patient had subcutaneous emphysema within 30 days after surgery. One patient had minor anastomosis site leakage. There was one 30-day mortality case. One patient with postoperative aspiration pneumonia developed acute respiratory distress disease, and died due to sepsis. Mean postoperative intensive care unit stay was 3.5 days, and mean postoperative hospital stay was 20.6 days. Nasogastric tubes were removed on average at 3.4 days, and mean oral intake time was 3.4 days. Conclusion: If the gastrointestinal surgeon has extensive experience in laparoscopic procedures, LGPU will be a safe and feasible technique for thoracic esophagectomy in patients with intrathoracic esophageal cancer.

Salvage of Esophageal Reconstruction with Colon Free Flap (대장유리피판(Colon Free Flap)을 이용한 식도재건의 구제술)

  • Lee, Sang Woo;Min, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.245-248
    • /
    • 2006
  • Besides gastric pull-up or colonic interposition, microvascular technique in esophageal reconstruction has been approved reliable methods. When free intestinal transfer is considered, jejunal free flap is commonly used. We treated the patient who had undergone reconstruction with a right colon interposition and suffered from inability of swallowing because of stricture and necrosis of the interposed flap. Although we have planned jejunal free transfer, we couldn't use jejunum due to adhesion by previous gastrojejunostomy and colon interposition. Salvage procedure with microvascualr free left colon flap was executed successfully. After 9 month follow-up, the patient was able to consume a normal diet.

A Modeling of Intermittent-Hydraulic-Gun-Aerator (간헐식 폭기형 수체순환장치 모델링)

  • Song, Mu-Seok;Seo, Dong-Il
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.3
    • /
    • pp.183-189
    • /
    • 2005
  • A modeling of a hydraulic-gun-aerator is proposed to set up a design procedure for such devices. The aerators are used to destroy any thermal stratification that are responsible for the degradation of water qualify of lakes. The aerator produces ascending flow by using air bubbies released instantly near the bottom of the lake into a cylindrical pipe installed vertically. Differently form the diffuser-aerators, they can pull up the cold, oxygen depleted water directly to the region of the free surface, and they are believed to work effectively especially for relatively deeper lakes. Their design procedure has not been established yet though, and we propose a model focusing on the exit flow velocity at the top of the aerator through the examination of presently operating devices.

An Efficient and High-gain Inverter Based on The 3S Inverter Employs Model Predictive Control for PV Applications

  • Abdel-Rahim, Omar;Funato, Hirohito;Junnosuke, Haruna
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1484-1494
    • /
    • 2017
  • We present a two-stage inverter with high step-up conversion ratio engaging modified finite-set Model Predictive Control (MPC) for utility-integrated photovoltaic (PV) applications. The anticipated arrangement is fit for low power PV uses, the calculated efficiency at 150 W input power and 19 times boosting ratio was around 94%. The suggested high-gain dc-dc converter based on Cockcroft-Walton multiplier constitutes the first-stage of the offered structure, due to its high step-up ability. It can boost the input voltage up to 20 times. The 3S current-source inverter constitutes the second-stage. The 3S current-source inverter hires three semiconductor switches, in which one is functioning at high-frequency and the others are operating at fundamental-frequency. The high-switching pulses are varied in the procedure of unidirectional sine-wave to engender a current coordinated with the utility-voltage. The unidirectional current is shaped into alternating current by the synchronized push-pull configuration. The MPC process are intended to control the scheme and achieve the subsequent tasks, take out the Maximum Power (MP) from the PV, step-up the PV voltage, and introduces low current with low Total Harmonic Distortion (THD) and with unity power factor with the grid voltage.

Anterior Instability of the Knee after Arthroscopic Treatment for Tibial Spine Fractures (경골극 골절의 관절경적 치료 후 슬관절의 전방 불안정성)

  • Choi, Chong-Hyuk;Kim, Sung-Hwan;Joo, Jong-Hwan;Kim, Hyung-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.26-32
    • /
    • 2006
  • Purpose: We evaluated the result of the degree of reduction and anterior instability after arthroscopic treatment of tibial spine fractures. Materials and Methods: Thirty-two cases of tibial spine fractures treated with arthroscopic procedure could be evaluated and the mean follow-up period was $18\;(12{\sim}48)$ months. Evaluations included Lachman test, rotatory instability examination and side to side difference (SSD) using KT-2000 arthrometer. The degree of radiologic reduction was classified as accurate reduction, anterior elevation and reduction failure, according to which the degree of anterior instability was measured. Results: There were twenty three cases (71%) of accurate duction, eight cases (25%) of anterior elevation and one case (4%) of education failure. Eight (29%) of twenty eight cases with pull-out method showed anterior elevation. The SSDs of the accurate reduction and the anterior elevation group were 2.0 mm and 2.8 mm, respectively showing no significant difference. However, the percent age of grade 0 Lachman test and SSD less than 3 mm of the accurate reduction group were significantly higher. Conclusion: Accurate reduction is important in reducing anterior instability especially in unstable fractures. Therefore, arthroscopic pull-out method should be performed with great caution to avoid anterior elevation of the fracture fragment.

  • PDF