• 제목/요약/키워드: Primary winding

검색결과 199건 처리시간 0.026초

자속구속형 한류기의 직병렬조합에 따른 전류제한특성 (Current Limiting Characteristics of Flux-lock Type Superconducting Fault Current Limiter Using YBCO Films by Serial and Parallel Combinations)

  • 박형민;조용선;이주형;정병익;최효상;최명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.87-88
    • /
    • 2007
  • We investigated the current limiting characteristics of flux-lock type superconducting fault current limiter using YBCO films University, Gwangju health college. The flux-lock type SFCL consisted of the transformer with a primary winding and a secondary winding connected in parallel, and the superconducting element was connected with secondary winding in series or parallel. Serial and parallel connections of superconducting elements are necessary for the increase of voltage and current capacities when we intend to apply the flux-lock type SFCL.

  • PDF

초전도 소자 병렬 연결에 따른 자속구속형 한류기의 전류제한 특성 (Current Limiting Characteristics of a Flux-lock type SFCL with Secondary Windings Connected to the Superconducting elements in parallel)

  • 박형민;조용선;최효상;오금곤;정수복;임성훈;최명호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.229-230
    • /
    • 2007
  • We investigated the quench characteristics of a superconducting element, two superconducting elements in order to increase the current capacity of flux lock type SFCL. The flux-lock type SFCL consisted of the transformer with a primary winding and a secondary winding connected in parallel, and the superconducting element was connected with secondary winding in series. The applied voltage at that time was 160 ${\sqrt{3}}$. We found that the parallel connection between the superconducting elements increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF

자기부상열차 추진용 리니어모터 효율향상 설계연구 (A Study on Design of Linear Motor for Maglev for High Efficiency)

  • 김윤현;김기찬
    • 전기학회논문지
    • /
    • 제65권4호
    • /
    • pp.561-566
    • /
    • 2016
  • In this paper, effective design method of linear induction motor(LIM) for Maglev is proposed in order to maximize system efficiency of Maglev. For the high system efficiency of Maglev, it is important to minimize weight of traction motor. Light weight design by changing materials of core and winding is conducted without changing volume of LIM. For the silicon steel core of primary part for magnetic flux path, iron-cobalt alloy steel with high magnetic saturation characteristic compared to silicon steel is suggested. Moreover, aluminium winding with light weight instead of copper winding is wounded in the widen slot area due to the high magnetic saturation level. For the verification of performance of proposed model, the characteristics are analyzed by using finite element method(FEM).

효율개선을 위한 Push-Pull Converter의 동기정류에 관한 연구 (A Study on Synchronous Rectification of Push-Pull Converter for Efficiency Improvement)

  • 김영규;김동중;김이훈;원충연;김규식;최세완
    • 전력전자학회논문지
    • /
    • 제9권2호
    • /
    • pp.134-141
    • /
    • 2004
  • 본 논문은 DC/DC 컨버터의 효율을 개선하기 위해 동기정류방식을 제시하였다. 제안된 동기정류 방식은 single winding self-driven synchronous rectification(SWSDSR)로서 1차측은 Push-Pull topology를 사용하였다. 특히 이 방식은 데드타임구간에도 동기정류 스위치를 온 시켜서 효율을 개선 할 수 있다. 최종적인 시뮬레이션과 실험 결과는 자기구동 동기정류(SDSR) 방식과 보조권선을 이용한 자기구동 동기정류(SWSDSR) 방식의 효율에 관한 비교와 해석을 보여준다.

Analysis on Current Limiting Characteristics of Transformer Type SFCL with Additionally Coupled Circuit

  • Lim, Seung-Taek;Ko, Seok-Cheol;Lim, Sung-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.533-539
    • /
    • 2018
  • In this paper, the transformer type superconducting fault current limiter (SFCL) with additionally coupled circuit was suggested and its peak fault current limiting characteristics due to the fault condition to affect the fault current were analyzed through the fault current limiting tests. The suggested transformer type SFCL is basically identical to the previous transformer type SFCL except for the additional coupled circuit. The additional coupled circuit, which consists of the magnetically coupled winding to the primary and the secondary windings together with another superconducting element and is connected in parallel with the secondary winding of the transformer type SFCL, is contributed to the peak fault current limiting operation for the larger transient fault current directly after the fault occurrence. To confirm the fault current limiting operation of the suggested SFCL, the fault current limiting tests of the suggested SFCL were performed and its effective peak fault current limiting characteristics were analyzed through the analysis on the electrical equivalent circuit.

물리적 처리가 잉크젯 코팅지 생산 과정 중에 발생되는 컬에 미치는 영향 (Effect of Physical Treatments on Curl in Inkjet Coated Paper During Papermaking)

  • 임연주;남원석;백기현
    • 펄프종이기술
    • /
    • 제36권2호
    • /
    • pp.39-46
    • /
    • 2004
  • In this paper, the effects of roll diameter and storage time in roll form, bending method and relative humidity on curl in copy paper and inkjet coated papers are investigated. In copy paper, more MD curl is showed at smaller roll diameter and the extension of bending time. However CD curl is hardly influenced by roll diameter and bending time. At high relative humidity, especially CD curl largely reduces. All inkjet coated papers without the primary or the secondary back coating during papermaking show the increase in MD curl and slight decrease in CD curl by MD bending regardless of the winding methods(TSO, TSI). The water spray as back coating results in the remarkable reduction of CD curl regardless of the winding methods. Drying on flat dryer after spraying the moisture on back side display the most excellent effect on the reduction of CD curl.

무접점 전원장치의 특성분석 (An Analysis on the Characteristics of the Contact-less Power Supply)

  • 이현관;이기식;정봉근;강성인;공영수;김은수;김윤호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.919-922
    • /
    • 2006
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss in contact-less power supply (CPS). In this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is analyzed and simulated. The results are verified on the simulation based on the theoretical analysis and the 1.8kW experimental prototype.

  • PDF

Magnetic Saturation Effect of the Iron Core in Current Transformers Under Lightning Flow

  • Kim, Young Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권2호
    • /
    • pp.97-102
    • /
    • 2017
  • A current transformer (CT) is a type of sensor that consists of a combination of electric and magnetic circuits, and it measures large ac currents. When a large amount of current flows into the primary winding, the alternating magnetic flux in the iron core induces an electromotive force in the secondary winding. The characteristics of a CT are determined by the iron core design because the iron core is saturated above a certain magnetic flux density. In particular, when a large current, such as a current surge, is input into a CT, the iron core becomes saturated and the induced electromotive force in the secondary winding fluctuates severely. Under these conditions, the CT no longer functions as a sensor. In this study, the characteristics of the secondary winding were investigated using the time-difference finite element method when a current surge was provided as an input. The CT was modeled as a two-dimensional analysis object using constraints, and the saturation characteristics of the iron core were evaluated using the Newton-Rhapson method. The results of the calculation were compared with the experimental data. The results of this study will prove useful in the designs of the iron core and the windings of CTs.

LLC DC to DC 공진 컨버터의 고주파 변압기 최적화 설계에 관한 연구 (A study on an optimal design of the high frequency transformer in LLC DC to DC resonant converter)

  • 김종해
    • 전기전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.587-600
    • /
    • 2023
  • 본 논문에서는 315W급 65인치 UHD-TV용 LLC DC to DC 공진 컨버터에 사용되고 있는 Slim형 고주파 변압기의 최적화 설계에 대해서 나타낸다. 또한 본 논문에서는 LLC 공진 변압기의 코어 손실 분석, AC 권선 손실 분석 및 권선 배치 최적화 설계를 통해 Slim형 고주파 변압기의 최적화 설계를 수행한다. 특히 본 논문에서는 이론적으로 해석하여 얻어진 결과를 토대로 고효율 및 Slim형 고주파 변압기는 교류 권선 손실 최소화 및 권선 자동화를 위하여 인터리브 및 수직형 권선 구조로 구성한다. 본 논문 제안한 수직형 권선 구조 방식의 Slim형 고주파 변압기의 1차측 권선은 Litz 권선을 2차 권선은 PCB와 동판 권선을 사용하였다. 최종적으로 Maxwell 2D 및 3D Tool을 이용한 시뮬레이션 결과를 토대로 이론 해석의 정당성을 입증하기 위해서 실험 결과를 통해 본 논문에서 제안한 Slim형 고주파 변압기의 최적화 설계를 수행하였다.

2차 권선을 직.병렬연결한 자속구속형 전류제한기의 퀜치특성 (Quench Characteristics of a Flux-lock type SFCL with Secondary Windings Connected in Serial and Parallel)

  • 박형민;조용선;최효상;오금곤;한태희;임성훈;황종선
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.432-434
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) according to the number of the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of the transformer with a primary winding and two secondary windings connected in parallel, and the superconducting element was connected with secondary winding in series, respectively. The applied voltage at that tin was 200V. when two superconducting elements of the secondary winding was connected in parallel, the peak lie current increased up to 99A, while that flowing in a superconducting element in conventional flux-lock type SFCL showed 50A under the same conditions, the impedance of secondary winding under the same situation showed the opposite behavior. This enabled the parallel structure to be easy to increase the capacity of power system, in the meantime, The quench between two superconducting elements in the SFCL with two secondary windings connected in parallel was achieved simultaneously. While the quench-starting point was slightly different in the SFCL with two superconducting elements connected in series. We found that the parallel connection between the secondary windings increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF