• 제목/요약/키워드: Pressure Sensors

검색결과 960건 처리시간 0.021초

The Optimization of the Number and Positions of Foot Pressure Sensors to Develop Smart Shoes

  • Yoo, Sihyun;Gil, Hojong;Kim, Jongbin;Ryu, Jiseon;Yoon, Sukhoon;Park, Sang Kyoon
    • 대한인간공학회지
    • /
    • 제36권5호
    • /
    • pp.395-409
    • /
    • 2017
  • Objective: The purpose of this study was to optimize the number and positions of foot pressure sensors using the reliability analysis of the center of pressure (COP) in smart shoes. Background: Foot pressure can be different according to foot region, and it is important which region of the foot pressure needs to be measured. Method: Thirty adults (age: $20.5{\pm}1.8years$, body weight: $71.4{\pm}6.5kg$, height: $1.76{\pm}0.04m$) participated in this study. The foot pressure data were collected using the insole of Pedar-X system (Novel GmbH, USA) with a sampling frequency of 100Hz during 1.3m/s speed walking on the treadmill (Instrumented treadmill, Bertec, USA). The intraclass correlation coefficients (ICC) were calculated between the COP positions using 4, 5, 6, 7, 8, and 99 sensors, while one-way repeated measure ANOVA was performed between the standard deviation (SD) of the COP positions. Results: The medio-lateral (M/L) COP position using 99 sensors was positively correlated with the M/L COP positions using 6, 7, and 8 sensors; however, it was not correlated with the M/L COP positions using 4 and 5 sensors during landing phase (1~4%) (p<.05). The antero-posterior (A/P) COP position using 99 sensors was positively correlated with the A/P COP positions using 4, 5, 6, 7, and 8 sensors (p<.05). The SD of the COP position using 99 sensors was smaller than the SD of the M/L COP positions using 4, 5, 6, 7, and 8 sensors (p<.05). Conclusion: Based on our findings, it is desirable to arrange at least 6 sensors in smart shoes. Application: The study of optimizing the number and positions of foot pressure sensors would contribute to developing more effective smart shoes using foot pressure technology.

A Mini Review of Recent Advances in Optical Pressure Sensor

  • Gihun Lee;Hyunjin Kim;Inkyu Park
    • 센서학회지
    • /
    • 제32권1호
    • /
    • pp.22-30
    • /
    • 2023
  • Innovative and advanced technologies, including robots, augmented reality, virtual reality, the Internet of Things, and wearable medical equipment, have largely emerged as a result of the rapid evolution of modern society. For these applications, pressure monitoring is essential and pressure sensors have attracted considerable interest. To improve the sensor performance, several new designs of pressure sensors have been researched based on resistive, capacitive, piezoelectric, optical, and triboelectric types. In particular, optical pressure sensors have been actively studied owing to their advantages, such as robustness to noise and remote sensing capability. Herein, a review of recent research on optical pressure sensors with self-powered sensing, remote sensing, high spatial resolution, and multimodal sensing capabilities is presented from the viewpoints of design, fabrication, and signal processing.

삽입된 광섬유 브래그 격자 센서를 이용한 필라멘트 와인딩된 복합재료 압력탱크의 내부 변형률 모니터링 (Internal Strain Monitoring of Filament Wound Pressure Tanks using Embedded Fiber Bragg Grating Sensors)

  • 김철웅;박상욱;박상오;김천곤;강동훈
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.17-20
    • /
    • 2005
  • In-situ structural health monitoring of filament wound pressure tanks were conducted during water-pressurizing test using embedded fiber Bragg grating (FBG) sensors. We need to monitor inner strains during working in order to verify the health condition of pressure tanks more accurately because finite element analyses on filament wound pressure tanks usually show large differences between inner and outer strains. Fiber optic sensors, especially FBG sensors can be easily embedded into the composite structures contrary to conventional electric strain gages (ESGs). In addition, many FBG sensors can be multiplexed in single optical fiber using wavelength division multiplexing (WDM) techniques. We fabricated a standard testing and evaluation bottle (STEB) with embedded FBG sensors and performed a water-pressurizing test. In order to increase the survivability of embedded FBG sensors, we suggested a revised fabrication process for embedding FBG sensors into a filament wound pressure tank, which includes a new protecting technique of sensor heads, the grating parts. From the experimental results, it was demonstrated that FBG sensors can be successfully adapted to filament wound pressure tanks for their structural health monitoring by embedding.

  • PDF

Triboelectrification based Multifunctional Tactile Sensors

  • Park, Hyosik;Kim, Jeongeun;Lee, Ju-Hyuck
    • 센서학회지
    • /
    • 제31권3호
    • /
    • pp.139-144
    • /
    • 2022
  • Advanced tactile sensors are receiving significant attention in various industries such as extended reality, electronic skin, organic user interfaces, and robotics. The capabilities of advanced tactile sensors require a variety of functions, including position sensing, pressure sensing, and material recognition. Moreover, they should comsume less power and be bio-friendly with human contact. Recently, a tactile sensor based on the triboelectrification effect was developed. Triboelectric tactile sensors have the advantages of wide material availability, simple structure, and low manufacturing cost. Because they generate electricity by contact, they have low power consumption compared to conventional tactile sensors such as capacitive and piezoresistive. Furthermore, they have the ability to recognize the contact material as well as execute position and pressure sensing functions using the triboelectrification effect. The aim of this study is to introduce the progress of research on triboelectrification-based tactile sensors with various functions such as position sensing, pressure sensing and contact material recognition.

부방향 동압력을 이용한 압전형 압력센서의 교정기법 (A Dynamic Calibration Technique for Piezoelectric Sensors Using Negative Going Dynamic Pressure)

  • 김응수
    • 한국군사과학기술학회지
    • /
    • 제12권4호
    • /
    • pp.491-499
    • /
    • 2009
  • The determination of response characteristics for pressure sensors is routinely limited to static calibration against a deadweight pressure standard. The strength of this method is that the deadweight device is a primary standard used to generate precise pressure. Its weakness lies in the assumption that the static and dynamic responses of the sensor in question are equivalent. Differences in sensor response to static and dynamic events, however, can lead to serious measurement errors. Dynamic techniques are required to calibrate pressure sensors measuring dynamic events in milliseconds. In this paper, a dynamic calibration using negative going dynamic pressure is proposed to determine dynamic pressure response for piezoelectric sensors. Sensitivity and linearity of sensor by the dynamic calibration were compared with those by the static calibration. The uncertainty of calibration results and the goodness of fit test of linear regression analysis were presented. The results show that the dynamic calibration is applicable to determine dynamic pressure response for piezoelectric sensors.

Quantitative Monitoring of Body Pressure Distribution Using Built-in Optical Sensors

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Seo, Jihyeon;Lee, Byunghun;Lee, Dongkyu;Kwon, Ohwon
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.279-282
    • /
    • 2020
  • In this study, body pressure was quantitatively detected using built-in optical sensors, inside an air cushion seat. The proposed system visualizes the effect of the body pressure distribution on the air cushion seat. The built-in sensor is based on the time-of-flight (ToF) optical method, instead of the conventional electrical sensor. A ToF optical sensors is attached to the bottom surface of the air-filled cells in the air cushion. Therefore, ToF sensors are durable, as they do not come in physical contact with the body even after repeated use. A ToF sensor indirectly expresses the body pressure by measuring the change in the height of the air-filled cell, after being subjected to the weight of the body. An array of such sensors can measure the body pressure distribution when the user sits on the air cushion seat. We implemented a prototype of the air cushion seat equipped with 7 ToF optical sensors and investigated its characteristics. In this experiment, the ToF optical pressure sensor successfully identified the pressure distribution corresponding to a sitting position. The data were accessed through a mobile device.

Flexible Pressure Sensors Based on Three-dimensional Structure for High Sensitivity

  • Jung, Young;Cho, Hanchul
    • 센서학회지
    • /
    • 제31권3호
    • /
    • pp.145-150
    • /
    • 2022
  • The importance of flexible polymer-based pressure sensors is growing in fields like healthcare monitoring, tactile recognition, gesture recognition, human-machine interface, and robot skin. In particular, health monitoring and tactile devices require high sensor sensitivity. Researchers have worked on sensor material and structure to achieve high sensitivity. A simple and effective method has been to employ three-dimensional pressure sensors. Three-dimensional (3D) structures dramatically increase sensor sensitivity by achieving larger local deformations for the same pressure. In this paper, the performance, manufacturing method, material, and structure of high-sensitivity flexible pressure sensors based on 3D structures, are reviewed.

초고온용 다결정 3C-SiC 마이크로 압력센서의 제작 (Fabrication of polycrystalline 3C-SiC micro pressure sensors for hightemperature applications)

  • 정귀상
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.31-35
    • /
    • 2010
  • High temperature micro pressure sensors were fabricated by using polycrystalline 3C-SiC piezoresistors grown on oxidized SOI substrates by APCVD. These have been made by bulk micromachining under $1{\times}1mm^2$ diaphragm and Si membrane thickness of $20{\mu}m$. The pressure sensitivity of implemented pressure sensors was 0.1 mV/$V{\cdot}bar$. The nonlinearity and the hysteresis of sensors were ${\pm}0.44%{\cdot}FS$ and $0.61%{\cdot}FS$. In the temperature range of $25^{\circ}C{\sim}400^{\circ}C$ with 5 bar FS, TCS (temperature coefficient of sensitivity), TCR (temperature coefficient of resistance), and TCGF (temperature coefficient of gauge factor) of the sensor were -1867 ppm/$^{\circ}C$, -792 ppm/$^{\circ}C$, and -1042 ppm/$^{\circ}C$, respectively.

FBG 센서 기술의 응용 사례 (Applications of Fiber Bragg Grating Sensor Technology)

  • 강동훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.3-9
    • /
    • 2006
  • Among many fabrication methods of composite materials, filament winding is the most effective method for fabricating axis-symmetric structures such as pressure tanks and pipes. Filament wound pressure tanks are under high internal pressure during the operation and it has the complexity in damage mechanisms and failure modes. Fiber optic sensors, especially FBG sensors can be easily embedded into the composite structures contrary to conventional electric strain gages (ESGs). In addition, many FBG sensors can be multiplexed in single optical fiber using wavelength division multiplexing (WDM) techniques. In this paper, we fabricated several filament wound pressure tanks with embedded FBG sensors and conducted some kinds of experiments such as an impact test, a bending test, and a thermal cycling test. From the experimental results, it was successfully demonstrated that FBG sensors are very appropriate to composite structures fabricated by filament winding process even though they are embedded into composites by multiplexing.

  • PDF

표면 MEMS 기술을 이용한 고온 용량형 압력센서의 특성 (Characteristics of Surface Micromachined Capacitive Pressure Sensors for High Temperature Applications)

  • 서정환;노상수;김광호
    • 한국전기전자재료학회논문지
    • /
    • 제23권4호
    • /
    • pp.317-322
    • /
    • 2010
  • This paper reports the fabrication and characterization of surface micromachined poly 3C-SiC capacitive pressure sensors on silicon wafer operable in touch mode and normal mode for high temperature applications. FEM(finite elements method) simulation has been performed to verify the analytical mode. The sensing capacitor of the capacitive pressure sensor is composed of the upper metal and the poly 3C-SiC layer. Measurements have been performed in a temperature range from $25^{\circ}C$ to $500^{\circ}C$. Fabrication process of designed poly 3C-SiC touch mode capacitive pressure sensor was optimized and would be applicable to capacitive pressure sensors that are required high precision and sensitivity at high pressure and temperature.