• 제목/요약/키워드: Power inverter

검색결과 3,963건 처리시간 0.031초

High-Frequency Zero Current Soft Switching Inverter with Pulse Density Modulation for Induction Heated Roller

  • Kang, Shin-Chul;Mun, Sang-Pil
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.49-57
    • /
    • 2008
  • This paper presents a voltage source type half-bridge series resonant high frequency (HF) inverter for induction heated fixing roller in copy machines. This high-frequency inverter works under zero current soft switching (ZCS) commutation and has wide power regulation range due to employing a pulse density modulation (PDM) scheme. Transient and steady state operating modes of the inverter are presented in this paper together with its PDM-based power regulation system. Experimental operating performances of the developed HF-ZCS inverter as well as power losses and actual efficiency are discussed and compared with computer simulation results.

An Isolated Soft-Switching Bidirectional Buck-Boost Inverter for Fuel Cell Applications

  • Zhang, Lianghua;Yang, Xu;Chen, Wenjie;Yao, Xiaofeng
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.235-244
    • /
    • 2010
  • This paper presents a new isolated soft-switching bidirectional buck-boost inverter for fuel cell applications. The buck-boost inverter combines an isolated DC-DC converter with a conventional inverter to implement buck-boost DC-DC and DC-AC conversion. The main switches achieve zero voltage switching and zero current switching by using a novel synchronous switching SVPWM and the volume of the transformer in the forward and fly-back mode is also minimized. This inverter is suitable for wide input voltage applications due to its high efficiency under all conditions. An active clamping circuit reduces the switch's spike voltage and regenerates the energy stored in the leakage inductance of the transformer; therefore, the overall efficiency is improved. This paper presents the operating principle, a theoretical analysis and design guidelines. Simulation and experimental results have validated the characteristics of the buck-boost inverter.

고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터 (Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise)

  • 이성호;권정민;권봉환
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.539-545
    • /
    • 2012
  • Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

외기온도와 부하변화에 따른 산업용 냉각기의 인버터제어 특성 (The Characteristic of Inverter Control by Variation of Refrigeration Load and Outdoor Temperature on Industrial Cooler)

  • 백승문
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.150-155
    • /
    • 2014
  • This paper presents The performance analysis of inverter control type-industrial cooler with respect to refrigeration load and outdoor temperature. Aside from materials about simulations and foundation data regarding inverter control compressors, currently, data about commercial coolers with inverter control still lack information for performance comparison. Thus, in this paper, the experiments are done to see characteristics of condensation capacity, evaporation capacity, compressor power and COP with respect to outdoor temperature and load by using a commercial inverter control cooler model. As a result, COP difference of the inverter control cooler with respect to load is 30% at the outdoor temperature of $35^{\circ}C$, 29% at the outdoor temperature of $30^{\circ}C$, 34% at $25^{\circ}C$, respectively.

마이크로프로세서를 사용한 고효율 인버터 안정기에 관한 연구 (A Study on Hight Efficiency Inverter Ballast using Microprocessor)

  • 정재륜
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.220-220
    • /
    • 1999
  • This paper describes the high efficiency inverter ballast circuit using very cheap microprocessor, which has been developed by the author. A variety of soft-switching techniques have been proposed to reduce the switching losses and EMI problems that occur with higher switching frequencies in switched inverter ballast. The inverter ballast circuit, which employs a temperature sensing circuits has been also proposed to improve starting performance of the fluorescent lamps. That is, the inverter ballast circuit, which employs a soft-starting circuit and soft-switching techniques to implement the power factor correction and to mitigate of power-loss and increase a life time of the fluorescent lamps, has become an attractive performance for ballasting the fluorescent lamps. In this paper, the operation and the control of the inverter ballast are described in detail and experimental results are presented. As the experimental results, when environment temperature is at -40℃, the inverter ballast circuit has low THD(4.8%) of the input current and large power factor(98%) of the lamp current. The proposed improved ballast circuit appears to be a good performance for ballasting fluorescent lamps.

3-레벨 PWM 인버터 전류산정에 관한 연구 (A Study on the computation of currents in the three-level PWM inverter)

  • 김광섭;서범석;현동석
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.341-351
    • /
    • 1996
  • The values for the average and rms currents in a three-level PWM inverter are required in order to select the various components such as power semiconductor devices, capacitors and reactors of inverter circuit. And those are very useful for the designing of the heat sink. In this paper, therefore, the simple current equations are proposed for a three-level PWM inverter. Analysis of inverter current waveforms indicate that the average and rms inverter currents are dependent on the load power factor and PWM modulation index (Ma). Error analysis and experiment results verify the effectiveness of the proposed current equations. (author). refs., figs., tabs.

  • PDF

3kW 멀티스트링 태양광 인버터 설계 및 시뮬레이션 (3kW multi-string photovoltaic inverter design and simulation)

  • 이종인;유병규;유권종;김흥근
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.371-376
    • /
    • 2009
  • The Power Conditioning System is Power Transfer System which make array DC current to the Grid sinusoidal current. These are Low Frequency Transformer Inverter Type, High Frequency Transformer Inverter Type and Transformer-less Type. Low Frequency Transformer Type has a Excellent Isolation property, but doesn't have competitiveness in Size and Cost. Also High Frequency Transformer Type has a good Isolation property but there are many steps in Power transfer Switching. Nowadays, Transformer-less Type inverter change a transformer to DC/DC Converter which is small and cost effective. In this paper shown the DC/DC Converter Transformer-less Type multi-string inverter design and simulation. The Control Algorithm will be introduced and Simulation was accomplished.

  • PDF

Design and Control of a Bidirectional Power Conversion System with 3-level T-type Inverter for Energy Storage Systems

  • Sung, Won-Yong;Ahn, Hyo Min;Oh, Chang-Yeol;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.326-332
    • /
    • 2018
  • In this paper, the design process and the control method of the power conversion system (PCS) that consists of a bidirectional DC-DC converter and a 3-level T-type inverter for an energy storage system is presented. Especially the design method of the output LCL filter for a 3-lvel T-type inverter without complex mathematical process are proposed. The validity of the control method and design process in this paper are verified through simulation and experimental analysis.

풀-브리지 인버터와 5-레벨 인버터의 직렬결합을 이용한 혼합형 멀티레벨 인버터 (Hybrid Multilevel Inverter Connecting a Full-bridge Inverter to a 5-level Inverter in Series)

  • 홍운택;최원균;권철순;강필순
    • 전력전자학회논문지
    • /
    • 제16권1호
    • /
    • pp.30-37
    • /
    • 2011
  • 본 논문에서는 풀-브리지 인버터와 양방향 스위치를 가지는 5-레벨 인버터를 직렬 결합시켜 출력전압에 다수의 레벨을 형성할 수 있는 멀티레벨 인버터 구조를 제안한다. 제안된 회로의 입력전압원 크기가 서로 동일한 경우와 3의 배수 형태를 가지는 경우에 대한 특성을 분석하고 시뮬레이션 및 실험을 통해 효율적인 혼합형 회로 구성을 제시한다. 또한 기존의 변압기를 이용한 방식과 비교하여 장단점을 분석한다.

CMOS 인버터의 최대 전력소모 예측을 위한 모델링 (A Modeling of CMOS Inverter for Maximum Power Dissipation Prediction)

  • 정영권;김동욱
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.1057-1060
    • /
    • 1998
  • Power Dissipation and circuit speed become the most importance parameters in VLSI system maximum power dissipation for VLSI system design. We remodeled CMOS inverter according to the operating region, saturation region or linear regin, and calculate maximum power dissipation point of CMOS inverter. The result of proposed maximum power dissipation model compared with those from SPICE simulation which results that the proposed maximum power dissipation model has the error rate within 10% to SPICE simulation.

  • PDF