DOI QR코드

DOI QR Code

Bi-directional Photovoltaic Inverter with High Efficiency and Low Noise

고 효율, 저 잡음 특성을 가지는 양방향 태양광 인버터

  • Lee, Sung-Ho (Div. of Electric. Electron. Eng., Pohang Univ. of science and technology) ;
  • Kwon, Jung-Min (Dept. of Electric. Eng., Hanbat National University) ;
  • Kwon, Bong-Hwan (Division of Electric. Electron. Eng., Pohang Univ. of science and technology)
  • Received : 2012.07.31
  • Accepted : 2012.10.22
  • Published : 2012.12.20

Abstract

Due to merits cost and efficiency, the transformer-less type photovoltaic (PV) inverters have been popularized in the solar market. However, the leakage current flowing through a parasitic capacitor between PV array and ground can cause adverse effect in the transformer-less PV system. In this paper, a bi-directional PV inverter with high efficiency and low noise is proposed for the PV system with an energy storage device. The proposed inverter is a transformer-less type and performs the bi-directional power control between dc sources and grid with high efficiency. In addition, the proposed inverter can suppress the leakage current and obtain low noise characteristic. Finally, 3-kW prototype was implemented to confirm validity of the proposed inverter.

Keywords

References

  1. M. H. Kuem, D. H. Jang, S. S. Hong, S. K. Han, and S. C. Sakong, "High power density and low cost photovoltaic power conditioning system with energy storage system," Transactions of the Korean Institute of Power Electronics, Vol. 16, No. 6, pp. 587-593, Dec. 2011. https://doi.org/10.6113/TKPE.2011.16.6.587
  2. H. W. Seo, J. M. Kwon, and B. H. Kwon, "Transformer -less three-phase line-connected photovoltaic PCS," Transactions of the Korean Institute of Power Electronics, Vol. 12, No. 5, pp. 355-363, Oct. 2007.
  3. H. Xiao and S. Xie, "Leakage current analytical model and application in single-phase transformerless photovoltaic grid-connected inverter," IEEE Trans. Electronmagn. Compat., Vol. 52, No. 4, pp. 902-913, Nov. 2011.
  4. B. Yang, Y. Gu, W. Cui, X. He, "Improved transformer -less inverter with common mode leakage current elimination for a photovoltaic grid-connected power system," IEEE Trans. Power. Electron., Vol. 27, No. 2, Feb. 2012.
  5. E. Gubia, P. Sanchis, A. Ursua, J. Lopez, and L. Marroyo, "Ground currents in single-phase transformer-less photovoltaic systems," Prog. Photovolt., Res. Appl., Vol. 15, No. 7, pp. 629-650, 2007. https://doi.org/10.1002/pip.761
  6. T. Kerekes, R. Teodorescu, P. Rodriguez, G. Vazquez, and E. Aldabas, "A new high efficiency single-phase transformerless PV inverter topology," IEEE Trans. Ind. Electron., Vol. 58, No. 1, Jan. 2011.
  7. M. Victor, F. Greizer, S. Bremicker, and U. Huebler, "Method of converting a direct current voltage from a source of direct current voltage, more specifically from a photovoltaic source of direct current voltage, into a alternating current voltage," United states Patent, US 7, 411, 802 B2, Aug. 2008.
  8. H. Schmidt, S. Christoph, and J. Ketterer, "Current inverter for direct alternating currents, has direct and alternating connections with an intermediate power store, a bridge circuit, rectifier diodes and a inductive choke," German Patent DE10 221 592 A1 4, Dec. 2003.
  9. R. Gonzalez, J. Lopez, P. Sanchis, and L. Marroyo, "Transformerless inverter for single-phase photovoltaic systems," IEEE Trans. Power Electron., Vol. 22, No. 2, pp. 693-697, Mar. 2007.
  10. M. Ciobotaru, V. G. Agelidis, R. Teodorescu, and F. Blaabjerg, "Accurate and less-disturbing active anti -islanding method based on PLL for grid-connected converters," IEEE Trans. Power Electron., Vol. 25, No. 6, pp. 1576-1584, Jun. 2010. https://doi.org/10.1109/TPEL.2010.2040088