• Title/Summary/Keyword: Power hardware-in-the-loop

Search Result 164, Processing Time 0.02 seconds

Low-power Hardware Design of Deblocking Filter in HEVC In-loop Filter for Mobile System (모바일 시스템을 위한 저전력 HEVC 루프 내 필터의 디블록킹 필터 하드웨어 설계)

  • Park, Seungyong;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.585-593
    • /
    • 2017
  • In this paper, we propose a deblocking filter hardware architecture for low-power HEVC (High-Efficiency Video Coding) in-loop for mobile systems. HEVC performs image compression on a block-by-block basis, resulting in blockage of the image due to quantization error. The deblocking filter is used to remove the blocking phenomenon in the image. Currently, UHD video service is supported in various mobile systems, but power consumption is high. The proposed low-power deblocking filter hardware structure minimizes the power consumption by blocking the clock to the internal module when the filter is not applied. It also has four parallel filter structures for high throughput at low operating frequencies and each filter is implemented in a four-stage pipeline. The proposed deblocking filter hardware structure is designed with Verilog HDL and synthesized using TSMC 65nm CMOS standard cell library, resulting in about 52.13K gates. In addition, real-time processing of 8K@84fps video is possible at 110MHz operating frequency, and operation power is 6.7mW.

Enhanced Method of Photovoltaic (PV) Cell Model Computation for Power Hardware-in-the-Loop Simulation (PHILS) of PV power Generation (태양광 발전의 Power Hardware-in-the-Loop Simulation (PHILS)을 위한 태양광 셀 모델의 연산 성능 향상기법)

  • Kwak, Sang Kyu;Kim, Ye-Rin;Jung, Jee Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.296-297
    • /
    • 2017
  • 태양광 발전에 있어서 실제 태양광 셀 특성은 날씨와 같은 환경 요인에 의존적이기 때문에 다양한 동작 조건에 대한 태양광 셀의 특성을 전력변환장치를 통해 테스트하기 위해 많은 시간과 비용이 소요된다. 이러한 문제를 해결하기 위해 Power Hardware-In-the-Loop Simulation (PHILS) 기술을 이용해 태양광 발전용 전력변환장치 시제품의 테스트 시간 및 비용을 단축할 수 있다. PHILS는 실시간 모의시험장치와 외부 입력이 가능한 전력변환장치로 구성되며, 해당 장치에서 모델의 동특성을 실시간으로 연산하기 때문에 모델이 복잡할수록 고성능 모의시험장치가 요구된다. 태양광 셀 모델의 출력 전압은 수치해석 기법을 통해 계산되고, 수치해석 기법의 종류와 초기 값에 따라 연산 시간 등의 성능이 변화하므로 적절한 기법을 선정하여 모델의 연산시간을 감소시킬 수 있다. 본 논문에서는 수치 해법 분석을 통한 태양광 발전의 PHILS를 위한 태양광 셀 모델의 연산 성능향상 기법을 제시하고, 실제 태양광 발전용 PHILS를 구현하여 실험적으로 제안하는 기법의 성능을 검증한다.

  • PDF

A study on advanced PV operation algorithm to improve the PV Power-Hardware-In-Loop Simulator (PV PHIL-시뮬레이터의 성능 개선을 위한 최적의 운영제어 알고리즘 연구)

  • Kim, Dae-Jin;Kim, Byungki;Ko, Hee-Sang;Jang, Moon-Seok;Ryu, Kyung-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.444-453
    • /
    • 2017
  • This paper proposes an operational algorithm for a Photovoltaic Power-Hardware-In-Loop Simulator that is designed to improve the control algorithm and reliability of the PV Inverter. There was an instability problem in the PV PHILS with the conventional algorithm when it was connected tothe PV inverter. Initially, a real-time based computing unit with mathematical modeling of the PV array is implemented and a DC amplifier and an isolated device for DC power measurement are integrated. Several experiments were performed based on theabove concept undercertain conditions, which showed that the proposed algorithm is more effective for the PV characteristic test and grid evaluation test than the conventional method.

Development of PV-Power-Hardware-In-Loop Simulator with Realtime to Improve the Performance of the Distributed PV Inverter (분산전원형 PV 인버터 성능 개선을 위한 실시간 처리기반의 PV-Power-Hardware-In-Loop 시뮬레이터 개발)

  • Kim, Dae-Jin;Kim, Byungki;Ryu, Kung-Sang;Lee, Gwang-Se;Jang, Moon-Seok;Ko, Hee-Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.47-59
    • /
    • 2017
  • As the global warming threats to humanity, renewable energy is considered the key solution to overcome the climate change. In this circumstance, distributed PV systems are being expanded significantly its market share in the renewable energy industry. The performance of inverter is the most important component at PV system and numerous researches are focusing on it. In order to improve the inverter, PV simulator is an essential device to experiment under various load and conditions. This paper proposes the PV Power-Hardware-In-Loop simulator (PHILS) with real-time processing converted electrical and mathematical models to improve computation speed. Single-diode PV model is used in MATLAB/SIMULINK for the PV PHILS to boosting computation speed and dynamic model accuracy. In addition, control algorithms for sub-components such as DC amplifier, measurement device and several interface functions are implemented in the model. The proposed PV PHILS is validated by means of experiments with commercial PV module parameters.

Power Decoupling Control of the Bidirectional Converter to Eliminate the Double Line Frequency Ripple (더블라인 주파수 제거를 위한 양방향 컨버터의 전력 디커플링 제어)

  • Amin, Saghir;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.62-64
    • /
    • 2018
  • In two-stage single-phase inverters, inherent double line frequency component is present at both input and output of the front-end converter. Generally large electrolytic capacitors are required to eliminate the ripple. It is well known that the low frequency ripple shortens the lifespan of the capacitor hence the system reliability. However, the ripple can hardly be eliminated without the hardware combined with an energy storage device or a certain control algorithm. In this paper, a novel power-decoupling control method is proposed to eliminate the double line frequency ripple at the front-end converter of the DC/AC power conversion system. The proposed control algorithm is composed of two loop, ripple rejection loop and average voltage control loop and no extra hardware is required. In addition, it does not require any information from the phase-locked-loop (PLL) of the inverter and hence it is independent of the inverter control. In order to prove the validity and feasibility of the proposed algorithm a 5kW Dual Active Bridge DC/DC converter and a single-phase inverter are implemented, and experimental results are presented.

  • PDF

Comparative Analysis of Three-Phase AC-DC Converters Using HIL-Simulation

  • Raihan, Siti Rohani Sheikh;Rahim, Nasrudin Abd.
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.104-112
    • /
    • 2013
  • This paper presents a comparative evaluation of various topologies for three-phase power converters using the hardware-in-the-loop (HIL) simulation technique. Various switch-mode AC-DC power converters are studied, and their performance with respect to total harmonic distortion (THD), efficiency, power factor and losses are analyzed. The HIL-simulation is implemented in an Altera Cyclone II DE2 Field Programmable Gate Array (FPGA) Board and in the Matlab/Simulink environment. A comparison of the simulation and HIL-simulation results is also provided.

Hardware-in-the-loop Simulation Method for a Wind Farm Controller Using Real Time Digital Simulator

  • Kim, Gyeong-Hun;Kim, Jong-Yul;Jeon, Jin-Hong;Kim, Seul-Ki;Kim, Eung-Sang;Lee, Ju-Han;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1489-1494
    • /
    • 2014
  • A hardware-in-the-loop simulation (HILS) method for a wind farm controller using a real time digital simulator (RTDS) is presented, and performance of the wind farm controller is analyzed. A 100 MW wind farm which includes 5 MW wind power generation systems (WPGS) is modeled and analyzed in RSCAD/RTDS. The wind farm controller is implemented by using a computer, which is connected to the RTDS through transmission control protocol/internet protocol (TCP/IP). The HILS results show the active power and power factor of the wind farm, which are controlled by the wind farm controller. The proposed HILS method in this paper can be effectively utilized to validate and test a wind farm controller under the environment in practice without a real wind farm.