Power Decoupling Control of the Bidirectional Converter to Eliminate the Double Line Frequency Ripple

더블라인 주파수 제거를 위한 양방향 컨버터의 전력 디커플링 제어

  • Amin, Saghir (Department of Electrical Engineering, Soongsil University) ;
  • Choi, Woojin (Department of Electrical Engineering, Soongsil University)
  • Published : 2018.11.30

Abstract

In two-stage single-phase inverters, inherent double line frequency component is present at both input and output of the front-end converter. Generally large electrolytic capacitors are required to eliminate the ripple. It is well known that the low frequency ripple shortens the lifespan of the capacitor hence the system reliability. However, the ripple can hardly be eliminated without the hardware combined with an energy storage device or a certain control algorithm. In this paper, a novel power-decoupling control method is proposed to eliminate the double line frequency ripple at the front-end converter of the DC/AC power conversion system. The proposed control algorithm is composed of two loop, ripple rejection loop and average voltage control loop and no extra hardware is required. In addition, it does not require any information from the phase-locked-loop (PLL) of the inverter and hence it is independent of the inverter control. In order to prove the validity and feasibility of the proposed algorithm a 5kW Dual Active Bridge DC/DC converter and a single-phase inverter are implemented, and experimental results are presented.

Keywords