• Title/Summary/Keyword: Power Hit

Search Result 91, Processing Time 0.035 seconds

Study on Hit Judgement Model of MMORPG - in case of Travia Online - (MMORPG 히트판정 모델에 관한 연구 - 트라비아 온라인을 중심으로 -)

  • Sohn Hyoung-Ryul
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.6
    • /
    • pp.172-177
    • /
    • 2005
  • Hit judgement is essential factor in design for battle-style MMORPG game system and sets foundation for other game systems. Hit judgement model consists of attack power and attack rate. The former contains minimum, maximum, and critical attack, the latter has miss, hit, and critical blow rate. Random function generates one value of attack rate and consequently the damage is calculated. In this article, we propose hit judgement model which Is widely acceptable for generic MMORPG and describe the effort of applying the proposed model to Travia Online in detail.

  • PDF

Research on Event Mechanism for Reducing Power Overheads in Cache Memory Synchronization (캐시 메모리 동기화 전력 감소를 위한 이벤트 메커니즘에 대한 연구)

  • Pak, Young-Jin;Jeong, Ha-Young;Lee, Yong-Surk
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.3
    • /
    • pp.69-75
    • /
    • 2011
  • In this paper, we propose an anycast event driven synchronization mechanism to reduce power overheads. Our proposed mechanism can reduce unnecessary polling operations on SHI(Snoop Hit Invalidate) or SHR(Snoop Hit Read) states. It prevents waisting bandwidth and reduces power overheads on polling operation. Also it decreases transition power of state change compared to broadcast model. Simulation results indicated that the proposed architecture had about 15.3% of power decrease compared to spin-lock model and about 4.7% of power decrease compared to broadcast model. Overall results indicated that proposed synchronization mechanism could increase power efficiency of multi-core system by reducing power overheads.

A Cache Hit Ratio based Power Consumption Model for Wireless Mesh Networks (무선 메쉬 네트워크를 위한 캐시 적중률 기반 파워 소모 모델)

  • Jeon, Seung Hyun;Seo, Yong-jun
    • Journal of Industrial Convergence
    • /
    • v.18 no.2
    • /
    • pp.69-75
    • /
    • 2020
  • Industrial IoT has much interested in wireless mesh networks (WMNs) due to cost effectiveness and coverage. According to the advance in caching technology, WMNs have been researched to overcome the throughput degradation of multihop environment. However, there is few researches of cache power consumption models for WMNs. In particular, a wired line based cache power consumption model in content-centric networks is not still proper to WMNs. In this paper, we split the amount of cache power from the idle power consumption of CPU, and then the cache hit ratio proportional power consumption model (CHR-model) is proposed. The proposed CHR-model provides more accurate power consumption in WMNs, compared with the conventional cache power efficiency based consumption model (CPE-model). The proposed CHR-model can provide a reference model to improve energy-efficient cache operation for Industrial IoT.

An analytical study on the Effect of High impedance Transformer to reduce Distribution Fault Current (변압기 임피던스 증가에 의한 배전계통의 고장전류 저감방안의 영향분석)

  • Lee, Hyun-Chul;Lee, Geun-Joon;Hyun, Ok-Bae;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.239_240
    • /
    • 2009
  • This paper presents the brief analytical study on 돋 effects of higher impedance transformer(HIT) to reduce distribution system fault current. With the increase of source and load capacity of power system, fault current of D/L is much more increased and, conventional protection equipment-such as sectionalizer and recloser, have to be replaced higher switching capacity. However, this replacements needs a lot of budget to utility. Increase of transformer impedance is can be a countermeasure in practical basis. This paper compares the voltage and fault current magnitude of both cases -%Zt=20% and %Zt2=33.3%(transformer capacity is 75/100MVA). The simulation results show that the steady state voltage of HIT is dropped 5~6% more in peak load, and fault current was decreased about 5kA by high impedance on transformer.

  • PDF

HIT PV Module Performance Research for an Improvement of Long-term Reliability: A Review

  • Park, Hyeong Sik;Jeong, Jae-Seong;Park, Chang Kyun;Lim, Kyung Jin;Shin, Won Seok;Kim, Yong Jun;Kang, Jun Young;Kim, Young Kuk;Park, No Chang;Nam, Sang-Hun;Boo, Jin-Hyo;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • v.5 no.2
    • /
    • pp.47-54
    • /
    • 2017
  • We report finding ways to improve the long-term reliability of PV module including the heterostructure with the intrinsic thin layer (HIT) solar cell. We point out the stability of the products of Panasonic HIT cell. We account for a brief description of the module manufacturing process to investigate the issues of each process and analyze the causes. We carried out the silicon PV module of the glass to glass type under the damp heat test around 1000 hours. However, it degraded around 7% of PV module power after 300 hours exposure in comparison with the initial status (Initial: 12.7 Watt). We investigated possible cause and solutions for the module performance to develop the long-term reliability.

Development of Fire Control System with an Analysis of Impact Vibration and Impact Energy (충격체의 진동 및 충격량 분석을 이용한 사격 통제장비 개발)

  • Lee, Dong-Hee;Lee, Jong-Heon;Youn, Ju-Houc;Park, Noh-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • This paper presents a development of a fire control system with an intelligent judgment algorithm of hit or not. The presented algorithm analyzes an impact energy and impact signals according to impact materials. And the detected signals are used to judge the correct hit or not. Furthermore, Zigbee wireless communication technology is applied in the developed fire control system. The wireless communication technology can supply a simple installation of the practical system and free from ageing of communication wire. The presented system is verified in the practical fire test, and the results show the effectiveness of the development system.

A Characteristic Study on the Power Factor Compensation Application of High Voltage Induction Motor (고압 유도전동기 역률 보상설비의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.225-230
    • /
    • 2008
  • Reactor starting method has the advantage of simplicity and closed transition in spite of lower starting torque per kVA. This method allows a smooth start with almost no observable disturbance on transition and is suitable for applications such as centrifugal pumps or fans. Reactive power doesn't contribute to work but needs to sustain the electromagnetic field required for the induction motor to operate. Starting power factor of induction motor is specially lower than running power factor. Power factor application is needed to compensate for the lower power factor of induction motor. This power factor compensation systems is occasionally being hit by the effects of the starting reactor connection position at the starting, stopping of high-voltage induction motor. This paper describes voltage and current stress affected by the installation position of power factor compensation application at the reactor starting method.

Image Objects Detection Method for the Embedded System (임베디드 시스템을 위한 영상객체의 검출방법)

  • Kim, Yun-Il;Rho, Seung-Ryong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.4
    • /
    • pp.420-425
    • /
    • 2009
  • In this paper, image detection and recognition algorithms are studied with respect to embedded carrier system. There are many suggested techniques to detect and recognize objects. But they have the propensity to need much calculation for high hit rate. Advanced and modified method needs to study for embedded systems that low power consumption and real time response are requested. The proposed methods were implemented using Intel(R) Open Source Computer Vision Library provided by Intel Corporation. And they run and tested on embedded system using a ARM920T processor by cross-compiling. They showed 1.6sec response time and 95% hit rate and supported the automated moving carrier system smoothly.

A Study on the Effect of Distributed Generation of the Reconfiguration of Distribution Networks

  • Nguyen, Tung Linh;Trinh, Trong Chuong;Truong, Viet Anh
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1435-1441
    • /
    • 2017
  • Distributed generation (DG) in the future will play an important role in the electricity supply systems, in wich can provide DG capacity from a few hundred kW to tens of MW. However, it is connected to the local power grid, DG will have certain influence on the power quality of the power grid. One of the most significant effects is that they will change the configuration of the local power grid as well as affecting the operation mode of the grid. This paper presents a method of finding the optimal open loop, analyzing and selecting the appropriate mode of operation to reduce power losses of power distribution networks that includes DG.

Analysis of Power Condenser Voltage Characteristics by Reactor Starting-operation (리액터 기동 운전시 콘덴서 전압 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong;Lee, Dong-Ju;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.619-620
    • /
    • 2008
  • Reactor starting method has the advantage of simplicity and closed transition in spite of lower starting torque per kVA. This method allows a smooth start with almost no observable disturbance on transition and is suitable for applications such as centrifugal pumps or fans. Starting power factor is specially low. Power factor application is needed to compensate for the lower power factor of induction motor. This power factor compensation systems is being hit by the effects of the starting reactor connection position. This paper describes voltage and current stress affected by the installation position of power factor compensation application at the reactor starting method.

  • PDF