• Title/Summary/Keyword: Poly(D

Search Result 1,084, Processing Time 0.028 seconds

Dependence of Dielectric breakdown of Thin Poly (Vinylidene Fluoride) Film on Temperature (Poly (Vinylidene Fluoride) 박막의 절연파괴와 온도의존성)

  • Kim, Dong-Wook;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.380-382
    • /
    • 1989
  • Dielectric breakdown strength (Eb) of thin Poly(Vinylidene Fluoride ; PVDF) film is studied in the temperature range between 4.2 K and 400 K. The results of this study can be summerized as follows. 1) Temperature dependence of dielectric breakdown strength (Eb) can be devided into high and low temperature regions. The critical temperature (Tc) at which two regions are devided depends on applied voltage. 2) Dielectric breakdown strength (Eb) by pulse voltage is higher than that by DC voltage. Especially this difference is remarkable at low temperature.

  • PDF

High Temperature Poly-Si TFT -LCD with Integrated Digital Data Drivers (디지털 데이터 구동회로가 내장된 고온 Poly-Si TFT-LCD)

  • Lim, Kyoung-Moon;Lee, Jong-Seok;Kim, Dong-Nam;Sung, Man-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.857-859
    • /
    • 1999
  • 본 연구에서는 Poly-Si TFT-LCD 패널에 내장할 수 있는 새로운 방식의 디지털 데이터 구동회로를 설계하였는데, 제안된 데이터 구동회로의 특징 및 장점을 요약하면 다음과 같다. 첫째, 단순한 구조의 샘플드램프 D/A Conversion 회로로 구성되어 회로가 복잡하지 않고, 소요되는 TFT의 수가 적으며, 패널의 스캔방식(Inversion Method : Row/Column/Dot)을 쉽게 선택할 수 있다. 둘째, 기존의 디지털 데이터 구동회로와는 달리, D/A Conversion을 위해 필요한 기준 전압원의 수가적어 입력 핀 수를 적게 가져갈 수 있다. 셋째, Ramp 신호의 조정에 의해 감마 보정 등을 포함한 데이터의 에러에 대한 보정이 수월하다. 넷째, 라인 스친 방식으로 구동하므로 기존의 샘플 앤 홀드방식의 아날로그 구동회로에 비해 화소 데이터의 시간적 안정성을 충분히 확보할 수 있다.

  • PDF

Atmospheric Metal Doping System and Application for Poly-Si Backplane

  • Shin, D.H.;Lee, J.M.;Lee, S.K.;Kim, H.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.87-90
    • /
    • 2007
  • VIATRON TECHNOLOGIES has developed an $\underline{A}$tmospheric $\underline{M}$etal $\underline{D}$oping (AMD) system which uniformly dopes metal species onto a substrate. The AMD system injects metal-organic vapor over substrate using an injection head with a scan motion. One of important application of this system is a metalinduced crystallization of amorphous Si for manufacturing AMOLED poly-Si panels. The AMD system with a use of Ni vapor source produces doping of trace amount of Ni onto amorphous Si, enabling uniform MIC crystallization. Also, the operation without vacuum condition offers advantages such as easy maintenance, low cost production, and large glass processes.

  • PDF

Design and Fabrication of Buried Channel Polycrystalline Silicon Thin Film Transistor (Buried Channel 다결정 실리콘 박막 트랜지스터의 설계 및 제작)

  • 박철민;강지훈;유준석;한민구
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.53-58
    • /
    • 1998
  • A buried channel poly-Si TFT (BCTFT) for application of high performance integrated circuits has been proposed and fabricated. BCTFT has unique features, such as the moderately-doped buried channel and counter-doped body region for conductivity modulation, and the fourth terminal entitled back bias for preventing kink effect. The n-type and p-type BCTFT exhibits superior performance to conventional poly-Si TFT in ON-current and field effect mobility due to moderate doping at the buried channel. The OFF-state leakage current is not increased because the carrier drift is suppressed by the p-n junction depletion between the moderately-doped buried channel and the counter-doped body region.

  • PDF

Characteristics of Programming on Analog Memory Cell Fabricated in a 0.35$\mu{m}$Single Poly Standard CMOS Process (0.35$\mu{m}$ 싱글폴리 표준 CMOS 공정에서 제작된 아날로그 메모리 셀의 프로그래밍 특성)

  • 채용웅;정동진
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.6
    • /
    • pp.425-432
    • /
    • 2004
  • In this paper, we introduce the analog memory fabricated in a 0.35${\mu}{\textrm}{m}$ single poly standard CMOS process. We measured the programming characteristics of the analog memory cell such as linearity, reliability etc. Finally, we found that the characteristics of the programming of the cell depend on the magnitude and the width of the programming pulse, and that the accuracy of the programming within 10mV is feasible under the optimal condition. In order to standardize the characteristics of the cell, we have investigated numbers of cells. Thus we have used a program named Labview and a data acquisition board to accumulate the data related to the programming characteristics automatically.

Effects of Blend Composition and Compatibilizer on the Mechanical Properties of Polypropylene/Acrylonitrile-Butadiene-Styrene Blends (블렌드 조성과 상용화제가 폴리프로필렌/ABS 블렌드의 기계적 물성에 미치는 영향)

  • Park, Jung-Hoon;Sung, Yu-Taek;Kim, Woo-Nyon;Hong, John-Hee;Hong, Byeong-Kwon;Yoo, Tae-Wook;Yoon, Ho-Gyu
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.19-24
    • /
    • 2005
  • Polymer blends containing polypropylene (PP) with compatibilizers were prepared using twin screw extruder. Physical properties were investigated using universal test machine (UTM) and Izod impact tester. In the PP/acrylonitrilebutadiene-styrene (ABS) blends, mechanical strength was increased with the addition of PP-g-styrene acryloritrile (PP-g-SAN) compatibilizer, and the ductility was increased with the addition of ethylene-ethyl acrylate-maleic anhydride (E-EAMAH-g-SAN) compatibilizer. For the PP/ABS/ polycarbonate (PC)/Nylon-6,6 blends, impact strength was increased with the addition of ethylene glycidylmethacrylate (E-GMA compatibilizer) up to 0.5 phr. In the case of the PP/ABS/PC/Nylon-6,6/poly(methyl methacrylate) (PMMA)/poly(oxymethylene) (POM)/poly(vinyl acetate) (PVC)/poly(butylene terephthalate) (PBT) blends, mechanical properties were increased by the complex compatibilizing effects of PP-g-SAN, E-EA-MAH-g-SAN and E-GMA, respectively.

Analysis of Grain Boundary Effects in Poly-Si Wafer for the Fabrication of Low Cost and High Efficiency Solar Cells (저가 고효율 태양전지 제작을 위한 다결정 실리콘 웨이퍼 결정입계 영향 분석)

  • Lee, S.E.;Lim, D.G.;Kim, H.W.;Kim, S.S.;Yi, J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1361-1363
    • /
    • 1998
  • Poly-Si grain boundaries act as potential barriers as well as recombination centers for the photo-generated carriers in solar cells. Thereby, grain boundaries of poly-Si are considered as a major source of the poly-Si cell efficiency was reduced This paper investigated grain boundary effect of poly-Si wafer prior to the solar cell fabrication. By comparing I-V characteristics inner grain, on and across the grain boundary, we were able to detect grain potentials. To reduce grain boundary effect we carried out pretreatment, $POCl_3$ gettering, and examined carrier lifetime. This paper focuses on resistivity variation effect due to grain boundary of poly-Si. The resistivity of the inner grain was $2.2{\Omega}-cm$, on the grain boundary$2.3{\Omega}-cm$, across the grain boundary $2.6{\Omega}-cm$. A measured resistivity varied depending on how many grains were included inside the four point probes. The resistivity increased as the number of grain boundaries increased. Our result can contribute to achieve high conversion efficiency of poly-Si solar cell by overcoming the grain boundary influence.

  • PDF

Induction of Potent Antigen-specific Cytotoxic T Cell Response by PLGA-nanoparticles Containing Antigen and TLR Agonist

  • Lee, Young-Ran;Lee, Young-Hee;Kim, Ki-Hyang;Im, Sun-A;Lee, Chong-Kil
    • IMMUNE NETWORK
    • /
    • v.13 no.1
    • /
    • pp.30-33
    • /
    • 2013
  • Previously we showed that biodegradable nanoparticles containing poly-IC or CpG oligodeoxynucleotide (ODN) together with ovalbumin (OVA) were efficient at inducing MHC-restricted presentation of OVA peptides in dendritic cells. The CTL-inducing activities of the nanoparticles were examined in the present study. Nanoparticles containing poly-IC or CpG ODN together with OVA were prepared using biodegradable polymer poly(D,L-lactic acid-co-glycolic acid), and then were opsonized with mouse IgG. The nanoparticles were injected into the tail vein of mice, and 7 days later the OVA-specific CTL activities were measured using an in vivo CTL assay. Immunization of mice with the nanoparticles containing poly-IC or CpG ODN together with OVA elicited potent OVA-specific CTL activity compared to those containing OVA only. In accordance with these results, nanoparticles containing poly-IC or CpG ODN together with OVA exerted potent antitumor activity in mice that were subcutaneously implanted with EG7.OVA tumor cells. These results show that encapsulation of poly-IC or CpG ODN together with antigen in biodegradable nanoparticles is an effective approach for the induction of potent antigen-specific CTL responses in vivo.

Preparation and Evaluation of Bupivacaine Microspheres by a Solvent Evaporation Method (용매증발법에 의한 부피바카인 microsphere의 제조 및 평가)

  • Kwak, Son-Hyok;Hwang, Sung-Joo;Lee, Byung-Chul
    • YAKHAK HOEJI
    • /
    • v.44 no.6
    • /
    • pp.511-520
    • /
    • 2000
  • Various bupivacaine-loaded microspheres were prepared from poly (d,l-lactide) (PLA) or poly (d,l-lactic-co-glycolide) (PLGA) by a solvent evaporation method for the sustained release of drug. PLA and PLGA microspheres were prepared by w/o/w and w/o/o multiple emulsion solvent evaporation, respectively. The effects of process conditions such as emulsification speed, emulsifier type, emulsifier concentration and internal/external phase ratio on the characteristics of microspheres were investigated. The prepared microspheres were characterized for their drug loading, size distribution, surface morphology and release kinetics. Drug loading efficiency was higher in the microspheres prepared by w/o/o multiple emulsion than that by w/o/w multiple emulsion method, because the solubility of bupivacaine HCI was decreased in oil phase compared with water phase. The prepared microspheres had an average diameter between 1 and $2\;{\mu}M$ in all conditions of two methods. In morphology studies the PLA microspheres showed an irregular shape and smooth surface, but PLGA microspheres had a spherical shape and smooth surface. The release pattern of the drug from microspheres was evaluated on the basis of the burst effect and the extent of the release after 24h. The in vitro release of bupivacaine HCl from microspheres showed a large initial burst release and $60{\sim}80%$ release within one day in all conditions of two methods. The extents of the burst release against PLA and PLGA microspheres were $30{\sim}50%$ and $50{\sim}80%$ within 20min, respectively. This burst release seems to be due to the smaller size of microspheres and the solubility of drug in water.

  • PDF

Preparation and Evaluation of Meloxicam-loaded Poly(D,L-lactic acid) Microspheres (멜록시캄 함유 poly (D,L-lactic acid) 미소립자의 제조 및 평가)

  • Im, Jong-Seob;Oh, Dong-Hoon;Li, Dong-Xun;Sung, Jung-Hoon;Yoo, Bong-Kyu;Kim, Jung-Ae;Woo, Jong-Soo;Lee, Yong-Bok;Kim, Se-Mi;Choi, Han-Gon;Yong, Chul-Soon
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.63-72
    • /
    • 2008
  • Meloxicam-loaded microspheres were prepared with poly(D,L-lactic acid)(PLA) by a solvent-emulsion evaporation method. The morphology, particle size, drug loading capacity, drug entrapment efficiency (EE) and release patterns of drug were investigated in vitro. Various batches of micro spheres with different size and drug content were obtained by changing the ratio of meloxicam to $PLA^{\circ}{\AE}s$ with different molecular weight, PLA concentration in the dispersed phase and stirring rate. Meloxicam crystals on microsphere surface, which were released rapidly and could act as a loading dose, were observed with increasing drug content. The release rate was increased with increase in drug contents and decrease in the molecular weight of PLA. Microspheres prepared with smaller molecular weight produced faster drug release rate. The release rate of meloxicam for long-acting injectable delivery system in vitro, which would aid in predicting in vivo release profile, could be controlled by properly optimizing various factors affecting characteristics of microspheres. Blood concentration-time profile of meloxicam after intramuscular injection of meloxicam-loaded microspheres in rabbits showed possibility of long term application of this system in clinical settings.