• Title/Summary/Keyword: Plan Unit

Search Result 1,096, Processing Time 0.03 seconds

Efficiency Plan for Agricultural Machinery Rental System of Local Government (지자체 농업기계 임대사업의 효율화 방안)

  • Shin, Seung-Yeoub;Kim, Byounggap;Kim, Yu Yong;Kim, Hyeong-Kwon;Lee, Kyou-Seung
    • Journal of Biosystems Engineering
    • /
    • v.37 no.6
    • /
    • pp.434-438
    • /
    • 2012
  • Purpose: This study was performed in order to improve problems and to seek the efficient operating plan by surveying and analyzing the actual status of operating the agricultural machinery rental business supported by the government. Method: The data was collected through two times of survey targeting lease business operators and the leasing business reports published for the past 3 years ('08~'10) 120 cities and counties. Results: As a result of surveying 120 cities and counties nationwide of operating the agricultural machinery rental business, 96% of agricultural machinery rental businesses were indicated to be operated in the form of short-term rent for about 1~3 days centering on small-sized agricultural machinery and attachment for upland crop. As for the unit number of possessing rental agricultural machinery and the purchase cost, it was indicated to be greatly reduced the agricultural machinery for rice farming and to be expanded into upland crop whose mechanization is insufficient. The annual rental days ('10) are 9.5 days/unit, thereby being a little insufficient. Rental fee for 1 day is 0.2~0.8% of the initial purchase cost of agricultural machine, thereby being greatly lower compared to 2.0% (annually 10-day rent) of the proper rents, resulting in being demanded improvement. Conclusions: To be continuously driven the rental business of agricultural machinery with having the ability to propagate, it is judged to be likely to necessarily collect optimum rental fee in consideration of rental days as well as increasing the use days per unit by buying the agricultural machinery, which is secured the rental demand, and by possessing the reasonable unit number.

Compound Linear Test Plan for 3-level Constant Stress Tests

  • Kim, In-Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.3
    • /
    • pp.945-952
    • /
    • 2006
  • Several accelerated life test plans use tests at only two levels of stress and thus, have practical limitations. They highly depend upon the assumption of a linear relationship between stress and time-to-failure and use only two extreme stresses that can cause irrelevant failure modes. Thus 3-level stress plans are preferable. When the lifetime distribution of test unit is exponential with mean lifetime $\theta_i$ at stress $x_i$, i=0, 1, 2, 3, we derive the optimum quadratic plan under the assumption that a quadratic relationship exists between stress and log(mean lifetime), and propose the compound linear plans, as an alternative to the optimum quadratic plan. The proposed compound linear plan is better than two other compromise plans for constant stress testing and nearly as good as the optimum quadratic plan, and has the advantage of simplicity.

  • PDF

A study on the Residential Satisfaction and Demands for the Comprehensive Apartment Improvement Planning (공동주택 거주자의 주거환경 만족도 및 개선요구를 통한 공동주택 장기수선 계획 연구)

  • Yoon Chung-Sook;Kim Soo-Jeong;Shin Soo-Young;Kim Suk-Kyung;Abrams Robin F.
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.37-46
    • /
    • 2006
  • The primary purpose of this study is to provide the managerial guidelines for the comprehensive apartment improvement planning. This plan will consider the time-serial apartment management plan. Through a questionnaire survey, residential satisfactions and demands on apartment units, apartment building and site amenities were investigated. Based on the statistical analysis, residents' demands were assessed. The resident groups were categorized into the three groups considering the apartments' life span where they were living. The results from the statistical analysis were finally compared with the long-term apartment management plan demonstrated in the Housing Code of the Ministry of Construction and Transportation. The major findings of this study were as follows. First, residential satisfaction on the equipments in apartment units was higher than that on the unit plans. Residents' satisfaction on the communal facilities in apartment sites was lower than that on the other factors. Thus, apartment unit plans and communal facilities in sites need to be improved. Second, though we had the three residents' groups, for the results of the residential satisfaction, the groups were divided into two groups: 'less than 10 years group'and 'over than 10 years group'. Considering the residents' demands for the apartment improvement according to the life span of apartment complexes, the habitability factor was demanded by 'the less than 10 years group' and the safety factor by 'the over than 10 years group'. Compared the residents' demands for apartment improvements with the long-term apartment management plan demonstrated in the Housing Code, the improvement cycles demanded by residents were shorter than those in the code. Thus, the management plan in the code should be reconsidered.

Development of the draft guidelines of the decommissioning plan for a nuclear power plant in Korea (국내 원자로시설 해체계획서 세부 작성지침(안) 개발)

  • Lee, Jungmin;Moon, Joohyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.3
    • /
    • pp.213-227
    • /
    • 2013
  • It is essential to prepare the decommissioning plan for a nuclear power plant (NPP) for the safe decommissioning of the NPP, minimization of the generation of decommissioning wastes, and protection of human beings and environment. Although Kori unit 1 and Wolsong unit 1 will be destined to their decommissioning in Korea in the near future. there is no provisons about preparing the decommissioning plan. In this paper, therefore, the draft guidelines of the decommissioning plan for a NPP were developed by considering the domestic situation, based on the comparative analyses of the regulatory guidelines of the decommissioning plan in U.S., U.K. and France. The draft guidelines are expected to play an important role to modify the domestic laws and regulations on the decommissioning of the NPP, and to give a license holder in charge of decommissioning the detailed instructions for preparing it in advance.

Changing Trend of Bathroom Space in Apartment Housing - With the cases of small size apartment housing established in 1966~1991 - (우리나라 공동주택 욕실 공간의 변화추이)

  • 심현숙
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1990.09a
    • /
    • pp.34-44
    • /
    • 1990
  • This study aimed to provide a basic data for presenting an appropriate plan of bathroom space which is suitable to our bathing behavior. We analized 1052 of small-sized apartment housing floor plans and the results were as follows. 1. Bathroom space were classified into 5 types : bath unit type, separated type, deficisncy type, over bath unit type, and semiseparated type and there was no separated type in this study. 2. The bathroom space type according to the size of housing 1) Deficiency type was the most popular one in 10-15 pyung sized housing. 2) In the size of 16-20 pyung housing, deficiency and bath unit type were popular ones. 3) Bath unit type was the most generalized one in 21-30 pyung. 4) Bath unit type and over unit type were generally equipped in 31-34 pyung housing. 3. The size of bathroom was ranged from 0.7 pyung to 2.0 pyung, and the ratio of it was 7.5- 12%.

  • PDF

Spatial Delineation of Planning Unit for Rural Village Improvement (농촌 생활환경 정비구역의 설정)

  • 조영국;김성진
    • Journal of Korean Society of Rural Planning
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 1998
  • The purpose of the study is to identify a basic spatial unit for rural village redevelopment plan. An ideal spatial unit need to satisfy three basic premises: to be homogeneous as rural community, to be appropriate to implement the project, and to be compatible with regional planning systems. A spatial unit could, empirically, be defined based on the homogeneity at first, and then appropriateness and compatibility could be used to adjust its boundary. Mitan-Myun(13 villages), Pyungchang County, Dochuck-Myun(15 villages), Kwangju County, and Chuksan-Myun(28 villages), Kimje City in Korea were selected as case study areas. The degree of interrelationship between all possible pairs in each Myun was measured using spatial, socio-cultural, and economic indicators. Multidimensional Scaling(MDS) was used to identify a homogeneous spatial unit, and then indicators representing appropriateness and compatibility were used to adjust the identified boundary. New districts which have two or three villages were suggested as a reasonable spatial unit for rural village redevelopment, and its boundary roughly overlaps with Bup-Jeong-Ri(法定里: a legally defined village).

  • PDF

Alternative Evaluation Model for Tower Crane Operation Plan in Modular Construction - Focusing on Modular Unit Installation and Finishing works - (모듈러 건축 타워크레인 운용 계획의 대안 평가 모델 - 유닛 설치 및 마감공사를 중심으로 -)

  • Kim, Joo Ho;Park, Moonseo;Lee, Hyun-Soo;Hyun, Hosang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.2
    • /
    • pp.50-60
    • /
    • 2018
  • Recently, modular construction method has been widely applied to projects with repetitive processes including dormitory, the residential facility, and the hotel construction due to reduced labor input and shortened construction schedule. Generally, about 40% of total on-site construction cost excluding unit installation cost, is put on exterior finishing work, and thus management of finishing work is deemed important in maintaining the targeted schedule and cost. Since limited equipment is shared so that subsequent activities are not affected while carrying out on-site installation and finishing work, lifting plan becomes more important for modular projects with greater portion of finishing work load. In this regard, tower crane operation plan may take the form of a single cycle or multiple cycles in which equipment efficiency can be affected. However, difficulties exist in evaluating alternatives to tower crane operation plans supporting unit installation and finishing work. Therefore, this study aims to evaluate the alternative of tower crane operation method according to the cyclic period setting in modular building site to determine the effect on T/C uptime and process by parameterizing lifting time for unit and exterior finishing material, lift cycle for unit and exterior finishing material and time required for finishing work. Accordingly, this study develops a simulation model that can increase the tower crane efficiency by controlling the work speed. An academic contribution of this study is to suggest a resource leveling method applying the concept of lifting cycle, and further is expected to be managerially used as a basis for an alternative evaluation of equipment plan.

The Characteristics of the Repair Unit Cost in Public Rental Housing (공공임대주택 단위 수선비용 특성 분석)

  • Lee, KangHee;Chae, ChangU
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.103-109
    • /
    • 2014
  • Apartment housing should require the systematic maintenance to provide the decent living condition during its life. Each household should participate the maintenance activities and pay for the repair. Therefore, the required cost for repair would be needed to plan in the repair schedule because each household could not pay the much repair money at a time. After apartment constructed, a long term repair plan would be prepared in repair time, repair scope and a required cost. A few studies are said that the repair cost depends on the building deterioration, elapsed year and management factors. The above factors are not be certain to affect the repair management while it may be important to prepare the required money and the repair time. In this paper, it aimed at analyzing the correlation between the repair management and the management factors, especially total area, number of household. This would educe the unit cost per number of household and management area in the individual boiler and elevator with full change and full repair. The unit cost per number of household and area for full change are about 199,000 won/household and $1,954won/m^2$ in the individual boiler respectively. The unit cost of the elevator for full change is 94,000 won/household and $5,429won/m^2$ respectively. Second, this study shows that the elapsed year after construction would not be related the repair unit cost.

A Study on a space utilization plan for screening clinic in public health center by means of the prevention of respiratory infectious disease - Focused on a negative pressured tuberculosis exam room (호흡기 감염병 예방을 위한 보건소 상시 선별진료소 활용방안 연구 - 음압 결핵 검진실을 중심으로)

  • Yoon, Hyung Jin;Han, Su Ha
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.4
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Tuberculosis(TB) care unit in public health center should be carefully considered to be re-designed as an infection safety environment for both patient and healthcare workers. So, for the enhancement, this study analyses the facility requirements for co-using the screening clinic as a TB and other respiratory disease care unit. Methods: Not only screening clinic facility guidelines from "A Study for Standard Triage Design and Construction Document" but also the guidelines of TB care and related medical facility are reviewed; KDCA, CDC, ECDC and WHO as a TB care, and FGI and NHS for facility. The facility requirements are summarized space, approach, and mechanical requirement in order. By comparing the summary and screening clinic facility guidelines, supplementations are proposed for TB care unit setting. Results: The result of this study shows that both the space program and mechanical requirement of the screening clinic and that of TB care unit are almost identical and could be share, which include direct airflow or negative air pressure in an exam room. To increase functional and economical efficiency, however, it is necessary to consider a multi-functional negative pressured room, So care process may be re-designed based on a room type; face-to-face room or glass wall inbetween. Implications: The facility guidelines for TB care unit of a public health center should be developed to build a safe environment for infection control by reflecting its medical plan and budget.