• Title/Summary/Keyword: Phase Calibration

Search Result 501, Processing Time 0.029 seconds

Analysis of the Influence of Atmospheric Turbulence on the Ground Calibration of a Star Sensor

  • Xian Ren;Lingyun Wang;Guangxi Li;Bo Cui
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.38-44
    • /
    • 2024
  • Under the influence of atmospheric turbulence, a star's point image will shake back and forth erratically, and after exposure the originally small star point will spread into a huge spot, which will affect the ground calibration of the star sensor. To analyze the impact of atmospheric turbulence on the positioning accuracy of the star's center of mass, this paper simulates the atmospheric turbulence phase screen using a method based on a sparse spectrum. It is added to the static-star-simulation device to study the transmission characteristics of atmospheric turbulence in star-point simulation, and to analyze the changes in star points under different atmospheric refractive-index structural constants. The simulation results show that the structure function of the atmospheric turbulence phase screen simulated by the sparse spectral method has an average error of 6.8% compared to the theoretical value, while the classical Fourier-transform method can have an error of up to 23% at low frequencies. By including a simulation in which the phase screen would cause errors in the center-of-mass position of the star point, 100 consecutive images are selected and the average drift variance is obtained for each turbulence scenario; The stronger the turbulence, the larger the drift variance. This study can provide a basis for subsequent improvement of the ground-calibration accuracy of a star sensitizer, and for analyzing and evaluating the effect of atmospheric turbulence on the beam.

Implementation of Single-Phase Energy Measurement IC (단상 에너지 측정용 IC 구현)

  • Lee, Youn-Sung;Seo, Hae-Moon;Kim, Dong Ku
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.12
    • /
    • pp.2503-2510
    • /
    • 2015
  • This paper presents a single-phase energy measurement IC to measure electric power quantities. The entire IC includes two programmable gain amplifiers (PGAs), two ${\sum}{\Delta}$ modulators, a reference circuit, a low-dropout (LDO) regulator, a temperature sensor, a filter unit, a computation engine, a calibration control unit, registers, and an external interface block. The proposed energy measurement IC is fabricated with $0.18-{\mu}m$ CMOS technology and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4,096 kHz and consumes 10 mW in 3.3 V supply.

Comparison of Calibration Models for GPS Antenna Phase Center Variations (GPS 안테나 위상중심변동 보정모델 비교)

  • Park, Kwan-Dong;Won, Ji-Hye
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.24 no.4
    • /
    • pp.319-326
    • /
    • 2006
  • To get the highly-accurate and precise position of a GPS receiver, they should consider the state-of-the-art GPS force and measurement models. Especially, the phase center variations (PCV) of a GPS antenna can cause several centimeters of positioning errors in the vertical direction. In this study, we implemented four different models of PCV and evaluated their impact on the computed coordinates. The test data were taken from the 14 National Geography Information Institute permanent GPS stations and 30 Minisry of Government Administration and Home Affairs sites. For different combinations of calibration methods, an average of 1.3-2.6cm of height difference was observed. Also, we found a maximum error of ${\sim}4mm$ in the estimates of the precipitable water vapors.

Development and Implementation of a 2-Phase Calibration Method for Gravity Model Considering Accessibility (접근성 지표를 도입한 중력모형의 2단계 정산기법 개발 및 적용)

  • CHOI, Sung Taek;RHO, Jeong Hyun
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.4
    • /
    • pp.393-404
    • /
    • 2015
  • Gravity model has had the major problem that the model explains the characteristics of travel behavior with only deterrence factors such as travel time or cost. In modern society, travel behavior can be affected not only deterrence factors but also zonal characteristics or transportation service. Therefore, those features have to be considered to estimate the future travel demand accurately. In this regard, there are two primary aims of this study: 1. to identify the characteristics of inter-zonal travel, 2. to develop the new type of calibration method. By employing accessibility variable which can explain the manifold pattern of trip, we define the zonal travel behavior newly. Furthermore, we suggest 2-phase calibration method, since existing calibration method cannot find the optimum solution when organizing the deterrence function with the new variables. The new method proceeds with 2 steps; step 1.estimating deterrence parameter, step 2. finding balancing factors. The validation results with RMSE, E-norm, C.R show that this study model explains the inter-zonal travel pattern adequately and estimate the O/D pairs precisely than existing gravity model. Especially, the problem with estimation of short distance trip is overcomed. In conclusion, it is possible to draw the conclusion that this study suggests the possibility of improvement for trip distribution model.

A Stability-Secured Loop Bandwidth Controllable Frequency Synthesizer for Multi-Band Mobile DTV Tuners

  • Kim, Kyeong-Woo;Akram, Muhammad Abrar;Hwang, In-Chul
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.3
    • /
    • pp.141-144
    • /
    • 2015
  • A broadband radio frequency synthesizer for multi-band, multi-standard mobile DTV tuners is proposed, it's loop bandwidth can be calibrated to optimize integrated phase noise performance without the problem of phase noise peaking. For this purpose, we proposed a new third-order scalable loop filter and a scalable charge pump circuit to minimize the variation in phase margin during calibration. The prototype phase-lock loop is fabricated in 180nm complementary metal-oxide semiconductor shows that it effectively prevents phase noise peaking from growing while the loop bandwidth increases by up to three times.

Temperature Calibration of a Specimen-heating Holder for Transmission Electron Microscopy

  • Kim, Tae-Hoon;Bae, Jee-Hwan;Lee, Jae-Wook;Shin, Keesam;Lee, Joon-Hwan;Kim, Mi-Yang;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • v.45 no.2
    • /
    • pp.95-100
    • /
    • 2015
  • The in-situ heating transmission electron microscopy experiment allows us to observe the time- and temperature-dependent dynamic processes in nanoscale materials by examining the same specimen. The temperature, which is a major experimental parameter, must be measured accurately during in-situ heating experiments. Therefore, calibrating the thermocouple readout of the heating holder prior to the experiment is essential. The calibration can be performed using reference materials whose phase-transformation (melting, oxidation, reduction, etc.) temperatures are well-established. In this study, the calibration experiment was performed with four reference materials, i.e., pure Sn, Al-95 wt%Zn eutectic alloy, NiO/carbon nanotube composite, and pure Al, and the calibration curve and formula were obtained. The thermocouple readout of the holder used in this study provided a reliable temperature value with a relative error of <4%.

Wavelength Calibration Solution of VPH Grating Slitless Spectroscopy Image

  • O, Seong A;Shin, Suhyun;Im, Myungshin;Yoon, Yongmin;Kim, Yongjung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.68.2-68.2
    • /
    • 2018
  • Spectroscopic observations commonly use a slit or fiber; however, non-slit spectroscopy enables us to observe a larger number of targets in one frame of image. Hence, it has been adopted as an observational mode for observatories like HST and JWST. Slitless spectroscopy requires wavelength calibration solutions in order to distinguish and measure the absorption / emission lines from the spectra with high accuracy. We installed the Volume Phase Holographic (VPH) grating to SQUEAN camera on the McDonald 2.1m telescope and obtained images with spectral resolutions of ~ 100 and 200. In order to derive the wavelength calibration, we measured the distances between the 0th order images and spectral features of various quasars. The distances are converted to wavelengths using the known wavelengths of the emission lines. We tested several different methods of spectral extraction and peak estimation of emission lines. We will present the results for the wavelength calibration and suggest the reliable methods to find the solution.

  • PDF

A study on the nonlinear error correction of the phase measuring profilometry (PMP 형상 측정법에서 비선형 오차보정에 관한 연구)

  • 황용선;강영준;박낙규;백성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.513-516
    • /
    • 2003
  • Phase Measuring Profilometry(PMP) has been developed as one of three dimensional 3-D shape measuring methods. The 3-D profile of an object was calculated from the phase data obtained by the sinusoidal patterns projected on the object. However, in some cases the approximation includes considerable errors. In this paper, the effect on the errors caused by the optical geometry and the calibration procedure in PMP technique are discussed. The errors which occured in the process of calculating the 3-D profile from the phase distribution are investigated theoritically and experimentally.

  • PDF

Calibration Method of Channels' Initial Phase Shift in Active Phased Array Antenna (능동 위상배열 안테나 채널의 초기위상 천이 보정 방법)

  • Mun, Yeong-Chan;Park, Chan-Gu;Pyo, Cheol-Sik;Jeon, Sun-Ik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.7
    • /
    • pp.18-23
    • /
    • 2000
  • An active phased away antenna consists of many channels including radiator and active circuitary that contains low noise amplifiers and phase shifters. Each channel has different initial phase shift and gain because of inequality in active circuitary itself, interface between radiator and active circuitary, beam forming network and other antenna configurations. This is an inherent problem in active phased away antenna, therefore each channels' initial phase shifts and gains should be calibrated for obtaining the designed radiation pattern and antenna gain. In this paper, an efficient calibration method for the active phased array antenna is presented. By performing the above method, thhe antenna gain is increased more than 2.0 dB after calibrating considerably unequal 12 channels' initial phase shifts and gains.

  • PDF

Evaluation for Phase displacement of Voltage Transformer Comparator (전압변성기 비교기의 위상각 오차 평가)

  • Han, Sang-Gil;Kim, Yoon-Hyoung;Jung, Jae-Kap;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2030-2031
    • /
    • 2008
  • We have developed the calibration technique of the VT comparator using nonreactive standard resistors and a standard capacitor, which evaluates both accuracy and linearity of the VT comparator by comparing experimental values with theoretical values. The specification for phase displacement of VT comparator have been revaluated.

  • PDF