• Title/Summary/Keyword: PV Inverter

Search Result 343, Processing Time 0.042 seconds

A Novel Multi-Function PV Micro-Inverter with an Optimized Harmonic Compensation Strategy

  • Zhu, Guofeng;Mu, Longhua;Yan, Junhua
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2284-2293
    • /
    • 2016
  • With the rapid development of clean energy, photovoltaic (PV) generation has been utilized in the harmonic compensation of power systems. This paper presents a novel multi-function PV micro-inverter with three stages (pseudo-two-stage). It can inject active power and compensate harmonic currents in the power grid at the same time. In order to keep the micro-inverter working under the maximum allowable output power, an optimized capacity limitation strategy is presented. Moreover, the harmonic compensation can be adjusted according to the customized requirements of power quality. Additionally, a phase shedding strategy in the DC/DC stage is introduced to improve the efficiency of parallel Boost converters in a wide range. Compared with existing capacity limitation methods, the proposed strategy shows better performance and energy efficiency. Simulations and experiments verify the feasibility of the micro-inverter and the effectiveness of the strategy.

Grid-Connected Photovoltaic System Based on a Cascaded H-Bridge Inverter

  • Rezaei, Mohammad-Ali;Iman-Eini, Hossein;Farhangi, Shahrokh
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.578-586
    • /
    • 2012
  • In this paper a single-phase Cascaded H-Bridge (CHB) inverter for photovoltaic (PV) applications is presented. Based on the presented mathematical analysis, a novel controller is introduced which adjusts the inverter power factor (PF) and manipulates the distribution of the reactive power between the cells to enhance the operating range of the CHB inverter. The adopted control strategy enables tracking of the maximum power point (MPP) of distinct PV strings and allows independent control of the dc-link voltages. The proposed controller also enables the inverter to operate under heavily unbalanced PV conditions. The performance of the CHB inverter and the proposed controllers are evaluated in the PSCAD/EMTDC environment. A seven-level CHB-based grid connected laboratory prototype is also utilized to verify the system performance.

Performance Evaluation with Protective Function test of Inverter for Solar Power Generation (태양광발전용 인버터 보호기능시험 성능평가)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

Design of Solar Inverter Monitoring System based on Smart-phone (스마트폰 기반의 태양광 인버터 모니터링 시스템 설계)

  • Kim, Gwan-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.539-540
    • /
    • 2012
  • 지구 온난화를 대비하여 PV(Photovoltaic)를 활용하여 생산된 전기를 산업현장이나 기타 다양한 분야에 활용되고 있다. 이러한 PV 시스템은 PV 어레이를 통하여 생산된 직류 전기를 인버터(inverter) 통하여 교류 전기로 전환하여 활용하고 있다. 더욱 현재에는 PV의 가격 하락으로 그 활용도가 높아 졌고 CO2 절감을 위해 정부차원에서 적극 장려하고 있다. 본 논문에서는 이러한 PV 기반의 발전 시스템을 모니터링하기 위하여 블루투스 모듈을 이용하여 데이터 브릿지를 설계하였다. 설계된 브릿지 모듈을 통하여 태양광 인버터에 대한 정보를 모니터링 할 수 있도록 하였으며, 주변 환경에 대한 환경 정보를 안드로이드 기반의 스마트폰에서 모니터링 하도록 하였다. 이러한 스마트폰 기반으로 스마트 그리드(smart grid) 시스템을 모니터링 할 수 있는 스마트한 모니터링 시스템을 제시하고자 한다.

  • PDF

A Modified Single-Phase Transformerless Z-Source Photovoltaic Grid-Connected Inverter

  • Liu, Hongpeng;Liu, Guihua;Ran, Yan;Wang, Gaolin;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1217-1226
    • /
    • 2015
  • In a grid-connected photovoltaic (PV) system, the traditional Z-source inverter uses a low frequency transformer to ensure galvanic isolation between the grid and the PV system. In order to combine the advantages of both Z-source inverters and transformerless PV inverters, this paper presents a modified single-phase transformerless Z-source PV grid-connected inverter and a corresponding PWM strategy to eliminate the ground leakage current. By utilizing two reversed-biased diodes, the path for the leakage current is blocked during the shoot-through state. Meanwhile, by turning off an additional switch, the PV array is decoupled from the grid during the freewheeling state. In this paper, the operation principle, PWM strategy and common-mode (CM) characteristic of the modified transformerless Z-source inverter are illustrated. Furthermore, the influence of the junction capacitances of the power switches is analyzed in detail. The total losses of the main electrical components are evaluated and compared. Finally, a theoretical analysis is presented and corroborated by experimental results from a 1-kW laboratory prototype.

Maximum Power Point Tracking Control of Photovoltaic System by using Current Solar Cell (태양전지 전류에 의한 계통연계형 태양광발전시스템의 최대출력 제어법)

  • 박인덕;성낙규;김대균;이승환;오봉환;김성남;한경희
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.109-112
    • /
    • 1998
  • A step down chopper and PWM current source inverter is used for the connection between the PV array and the utility. This paper proposes chopper is controlled for the dc reactor decrease and PWM current source inverter is controlled to keep the output power at the maximum point for the PV. The PV current only is measured and employed for the power calculation combining the control parameter of the PWM current source inverter.

  • PDF

Cascaded H-Bridge Five Level Inverter for Grid Connected PV System using PID Controller

  • Sivagamasundari, M.S.;Mary, P. Melba
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.451-462
    • /
    • 2016
  • Photovoltaic energy conversion becomes main focus of many researches due to its promising potential as source for future electricity and has many advantages than the other alternative energy sources like wind, solar, ocean, biomass, geothermal etc. In Photovoltaic power generation multilevel inverters play a vital role in power conversion. The three different topologies, diode-clamped (neutral-point clamped) inverter, capacitor-clamped (flying capacitor) inverter and cascaded h-bridge multilevel inverter are widely used in these multilevel inverters. Among the three topologies, cascaded h-bridge multilevel inverter is more suitable for photovoltaic applications since each pv array can act as a separate dc source for each h-bridge module. This paper presents a single phase Cascaded H-bridge five level inverter for grid-connected photovoltaic application using sinusoidal pulse width modulation technique. This inverter output voltage waveform reduces the harmonics in the generated current and the filtering effort at the input. The control strategy allows the independent control of each dc-link voltages and tracks the maximum power point of PV strings. This topology can inject to the grid sinusoidal input currents with unity power factor and achieves low harmonic distortion. A PID control algorithm is implemented in Arm Processor LPC2148. The validity of the proposed inverter is verified through simulation and is implemented in a single phase 100W prototype. The results of hardware are compared with simulation results. The proposed system offers improved performance over conventional three level inverter in terms of THD.

Suppression of Common-Mode Voltage in a Multi-Central Large-Scale PV Generation Systems for Medium-Voltage Grid Connection (중전압 계통 연계를 위한 멀티 센트럴 대용량 태양광 발전 시스템의 공통 모드 전압 억제)

  • Bae, Young-Sang;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.31-40
    • /
    • 2014
  • This paper describes an optimal configuration for multi-central inverters in a medium-voltage (MV) grid, which is suitable for large-scale photovoltaic (PV) power plants. We theoretically analyze a proposed common-mode equivalent model for problems associated with multi-central transformerless-type three-phase full bridge(3-FB) PV inverters employing two-winding MV transformers. We propose a synchronized PWM control strategy to effectively reduce the common-mode voltages that may simultaneously occur. In addition, we propose that the existing 3-FB topology may also have the configuration of a multi-central inverter with a two-winding MV transformer by making a simple circuit modification. Simulation and experimental results of three 350kW PV inverters in a multi-central configuration verify the effectiveness of the proposed synchronization control strategy. The modified transformerless-type 3-FB topology for a multi-central PV inverter configuration is verified using an experimental prototype of a 100kW PV inverter.

A Study on Real Test of an Incremental Conductance MPPT Control Based Photovoltaic Inverter (증분컨덕턴스 제어적용 태양광 인버터 실증시험에 관한 연구)

  • Kim, Eung-Sang;Kim, Seul-Ki;Jeon, Jin-Hong;Ahn, Jong-Bo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1211-1217
    • /
    • 2007
  • In this paper, a 10kVA PV inverter applying Incremental Conductance(IncCond) method for maximum power point tracking WIS developed and its performance tests were carried out. Modeling and simulation of PV array and system controller was performed using PSCAD/EMTDC, an electromagnetic transient analysis program. After comparison and analysis of Perturbation & Observation (P & O) and IncCond method, a PV inverter based on IncCond method was designed and manufactured. Grid interface transient characteristics including start-up, normal operation, and fault operation were tested, which verified the usefulness of the proposed system. In the near future, commercialization process will proceed through additional extensive tests of transients.

The research for appropriate input capacitor selection of PV inverter in Distributed Generation (분산전원 PV 인버터의 적절한 입력커패시터 선정 고찰)

  • Lee, Kyung-Soo;Jung, Young-Seck;Kang, Gi-Hwan;Yu, Gwon-Jong;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.259-261
    • /
    • 2003
  • Generally, there is an input capacitor in front of PV(Photovoltaic) inverter in DG(Distributed Generation). This input capacitor mainly works in order to stabilize the PV output voltage. However, input capacitors, which are being used in domestic market are not well known about their appropriate value and also there is no information for selecting the suitable value of input capacitor. Therefore, the author suggests that the stand-alone PV inverter is considered to analyse appropriate value of input capacitor and then recommends the appropriate value of input capacitor through simulation.

  • PDF