• Title/Summary/Keyword: Open circuit

Search Result 1,163, Processing Time 0.025 seconds

Study for the Operational Characteristics of Closed Circuit Hydraulic System of Turnover-Type Sluice Gate (전도 수문용 폐회로형 유압장치의 작동 특성에 관한 연구)

  • Lee, Seong-Rae
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.897-902
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the open circuit hydrauic system since the single-rod cylinder is used rather than the double-rod cylinder. However, here the closed circuit hydrauic system is applied for the operation of turnover-type sluice gate for the purpose of convenient operation. The closed circuit hydraulic system of turnover-type sluice gate is composed of a bi-directional pump, single-rod cylinders, pilot operated check valves, check valves and a counter balance valve. The usefulness of the closed circuit hydraulic system is verified for the several operational conditions by the computer simulations.

  • PDF

Design of the Protection circuit for Electric ballast with $LC_SC_P$ resonance type Half-bridge Inverter ($LC_SC_P$ 공진 타입의 하프 브리지 인버터 구조를 가지는 전자식 안정기 보호회로 설계)

  • Choe, Hyeon-Hui;Park, Chong-Yun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1538-1543
    • /
    • 2009
  • The electric ballast for ceramic metal halide lamp needs a protection circuit to prevent from over voltage and over current in the case that the lamp or the electric ballast are in faults. In this paper, cost-effective and high performance protection circuit is proposed for the electric ballast. The proposed protection circuit is adapted to the electric ballast with $LC_SC_P$ resonance type half bridge inverter. The experimental results demonstrate that the proposed circuit can protect effectively under open and short fault conditions.

Proposed Equivalent Circuit and Parameter Identification Method for Electro-Magnetic Resonance Based Wireless Power Transfer

  • Kawamura, Atsuo;Kim, Tae-Woong
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.799-807
    • /
    • 2013
  • The proper equivalent circuit is newly presented for electro-magnetic resonance based wireless power transfer. Based on the proposed equivalent circuit of open-ended helical antennas, the parameter identification of helical antennas can be well derived for highly efficient wireless power transfer. The well-established equivalent circuit in high frequency ranges is developed for analyzing a resonance enhanced-electromagnetic coupling helical antennas and the unknown parameters for helical antennas are identified by experiments. The effectiveness based on the proposed equivalent circuit is verified through experiments.

A Fault Diagnosis Method in Cascaded H-bridge Multilevel Inverter Using Output Current Analysis

  • Lee, June-Hee;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2278-2288
    • /
    • 2017
  • Multilevel converter topologies are widely used in many applications. The cascaded H-bridge multilevel inverter (CHBMI), which is one of many multilevel converter topologies, has been introduced as a useful topology in high and medium power. However, it has a drawback to require a lot of switches. Therefore, the reliability of CHBMI is important factor for analyzing the performance. This paper presents a simple switch fault diagnosis method for single-phase CHBMI. There are two types of switch faults: open-fault and short-fault. In the open-fault, the body diode of faulty switch provides a freewheeling current path. However, when the short-fault occurs, the distortion of output current is different from that of the open-fault because it has an unavailable freewheeling current flow path due to a disconnection of fuse. The fault diagnosis method is based on the zero current time analysis according to zero-voltage switching states. Using the proposed method, it is possible to detect the location of faulty switch accurately. The PSIM simulation and experimental results show the effectiveness of proposed switch fault diagnosis method.

Comparison of Electrical Properties and AFM Images of DSSCs with Various Sintering Temperature of TiO2 Electrodes (TiO2 전극의 소결 온도에 따른 DSSCs의 전기적 특성 및 AFM 형상 비교)

  • Kim, Hyun-Ju;Lee, Dong-Yun;Lee, Won-Jae;Koo, Bo-Kun;Song, Jae-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.6
    • /
    • pp.571-575
    • /
    • 2005
  • In order to improve the efficiency of dye-sensitized solar cell (DSSC), $TiO_2$ electrode screen-printed on transparent conducting oxide (TCO) substrate was sintered in variation with different temperature$(350\;to\;550^{\circ}C)$. $TiO_2$ electrode on fluorine doped tin oxide (FTO) glass was assembled with Pt counter electrode on FTO glass. I-V properties of DSSCs were measured under solar simulator. Also, effect of sintering temperature on surface morphology of $TiO_2$ films was investigated to understand correlation between its surface morphology and sintering temperature. Such surface morphology was observed by atomic force microscopy (AFM). Below sintering temperature of $500^{\circ}C$, efficiency of DSSCs was relatively lower due to lower open circuit voltage. Oppositely, above sintering temperature of $500^{\circ}C$, efficiency of DSSCs was relatively higher due to higher open circuit voltage. In both cases, lower fill factor (FF) was observed. However, at sintering temperature of $500^{\circ}C$, both efficiency and fill factor of DSSCs were mutually complementary, enhancing highest fill factor and efficiency. Such results can be explained in comparison of surface morphology with schematic diagram of energy states on the $TiO_2$ electrode surface. Consequently, it was considered that optimum sintering temperature of a-terpinol included $TiO_2$ paste is at $500^{\circ}C$.

Analysis and comparison of initial performance degradation for single crystalline silicon solar cell under open and short circuit (단결정 태양전지의 단락 및 개방 시 노광에 의한 초기 출력저하 비교 분석)

  • Jung, Tae-Hee;Kim, Tae-Bum;Shin, Jun-Oh;Yoon, Na-Ri;Woo, Sung-Cheol;Kang, Gi-Hwan;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.16-21
    • /
    • 2010
  • It is well-known that Boron-doped Cz Si solar cells suffer light-induced degradation due to boron-oxygen defect which is responsible of a reduction in lifetime and hence efficiency. In this paper, we assume that PV solar cell has been connected with variable load to account the real operating condition and it shows different light-induced degradation of Si solar cell. To evaluate the effect of light-induced degradation for solar cell with various load, Single crystalline solar cells are connected with open and short circuits during light exposure. Isc-Voc curve evaluate light induced degradation of solar cells and the reason is explained as a change for serial resistance. From the results, Electrical characteristics of solar cells show better performance under short circuit conditions, after light exposure.

Empirical Model of Via-Hole Structures in High-Count Multi-Layered Printed Circuit Board (HCML 배선기판에서 비아홀 구조에 대한 경험적 모델)

  • Kim, Young-Woo;Lim, Yeong-Seog
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.12
    • /
    • pp.55-67
    • /
    • 2010
  • The electrical properties of a back drilled via-hole (BDH) without the open-stub and the plated through via-hole (PTH) with the open-stub, which is called the conventional structure, in a high-count multi~layered (HCML) printed circuit board (PCB) were investigated for a high-speed digital system, and a selected inner layer to transmit a high-speed signal was farthest away from the side to mount the component. Within 10 GHz of the broadband frequency, a design of experiment (DOE) methodology was carried out with three cause factors of each via-hole structure, which were the distance between the via-holes, the dimensions of drilling pad and the anti-pad in the ground plane, and then the relation between cause and result factors which were the maximum return loss, the half-power frequency, and the minimum insertion loss was analyzed. Subsequently, the empirical formulae resulting in a macro model were extracted and compared with the experiment results. Even, out of the cause range, the calculated results obtained from the macro model can be also matched with the measured results within 5 % of the error.

Open Fault Diagnosis Method for Five-Phase Induction Motor Driving System (5상 유도전동기 구동 시스템을 위한 인버터의 개방고장진단 방법)

  • Baek, Seung-Koo;Shin, Hye-Ung;Kang, Seong-Yun;Park, Choon-Soo;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.304-310
    • /
    • 2016
  • This paper proposes a fault diagnosis method for an open-fault in inverter driving five-phase induction motor. The five-phase induction motor has a high output torque and small torque ripple in comparison to three-phase. The best advantage of the five-phase induction motor is fault diagnosis and tolerant control using redundancy of phases. This paper uses an inverter as a power converter for driving a five-phase induction motor. If a switch of inverter occurs to the open-fault, this problem is the influence on the output current and output torque. To solve this problem, there is need of an accurate diagnosis and fault switch distinction. Therefore, this paper propose a fault detection method of the open-fault switches for the fault diagnosis. First, analyzing the pattern for the open-circuit fault of one phase. next, analyzing the pattern for the open-circuit fault of each inverter switches. Through the pattern analysis, It defines the scope of each of the failure switch. Thereafter, By using an algorithm that proposes to perform a fault diagnosis method. The proposed algorithm is verified from the experiment with the 1.5 kW five-phase induction motor.

Particle-Size Distribution Dependent upon Crushing Mechanism and Crushing Circuit (파쇄 메카니즘과 파쇄회로에 따른 입도분포)

  • Choi, Do-Young;Kim, Wan-Tae;Kim, Sang-Bae
    • Journal of the Mineralogical Society of Korea
    • /
    • v.23 no.4
    • /
    • pp.297-303
    • /
    • 2010
  • We report the particle-size distribution and comminution charactersitics of dolomite depending upon crushing equipment (hammer crusher and roll crusher) and crushing circuit (open and closed). The quantity of fine particles (< 100 mesh) produced by hammer crusher was 34 wt.% which is about three times that by roll crusher. The quantity of 14~25 mesh size fraction by roll crusher was 20 wt.% higher than that produced by hammer crusher. 80 wt.% of the crushing products by hammer crushing was under 35 mesh in size, while the particles produced by roll crushing were relatively coarse. The particle size of both the hammer and roll crushers decreased by employing closed crusing circuit in comparison to open circuit. Products of required particle-size were obtained effectively depending on appropriate crushing equipment and crushing circuit.

A study on the construction of nic circuit and ists application to oscilation circuit (Nic 회로의 구성 및 발진회로에의 응용에 관한 연구)

  • 김명기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.6
    • /
    • pp.16-24
    • /
    • 1974
  • In this paper the method of constructing short and open stable voltage inversion negative immittance converter (VNIC) circuits is proposed according to simplified equivalent models witch consist of a parameter control circuit, and a voltage or a current control circuit. VNIC characteristics can be obtained as gate voltage of common gate connection is controlled by the output of the parameter control circuit corresponding to its input. Constructed circuits are analysed, and the experimental results are compared and cheeked with the calculated results. Errors are found less than 11%. Oscillation behavior of constructed VNIC oscillator is compared with that of negative resistance oscillator.

  • PDF