• Title/Summary/Keyword: On-body device

Search Result 794, Processing Time 0.026 seconds

Program Efficiency of Nonvolatile Memory Device Based on SOI(Silicon-on-Insulator) under Partial and Full Depletion Conditions (SOI (Silicon-on-Insulator) 기반의 비휘발성 메모리 소자의 부분공핍 및 완전공핍 상태에서의 프로그램 효율)

  • Cho, Seong-Jae;Park, Il-Han;Lee, Jung-Hoon;Son, Young-Hwan;Lee, Jong-Duk;Shin, Hyung-Cheol;Park, Byung-Gook
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.395-396
    • /
    • 2008
  • There is difficulty in predicting the program efficiency of NOR type nonvolatile memory device adopting channel hot electron injection (CHEI) as program operation mechanism accurately since MOSFET on SOI has floating body. In this study, the dependence of program efficiency for SOI nonvolatile memory device of 200 nm channel length on SOI depletion conditions, partial depletion and full depletion, was quantitatively investigated with the aid of numerical device simulation [1].

  • PDF

A study on digital locking device design using detection distance 13.4mm of human body sensing type magnetic field coil (인체 감지형 자기장 코일의 감지거리 13.4mm를 이용한 디지털 잠금장치 설계에 관한 연구)

  • Lee, In-Sang;Song, Je-Ho;Bang, Jun-Ho;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • This study evaluated a digital locking device design using detection distance of 13.4mm of a human body sensing type magnetic field coil. In contrast to digital locking devices that are used nowadays, the existing serial number entering buttons, lighting, number cover, corresponding pcb, exterior case, and data delivery cables have been deleted and are only composed of control ON/OFF power switches and emergency terminals. When the magnetic field coil substrates installed inside the inner case detects the electric resistance delivered from the opposite side of the 12mm interval exterior contacting the glass body part, the corresponding induced current flows. At this time, the magnetic field coil takes the role as a sensor when coil frequency of the circular coil is transformed. The magnetic coil as a sensor detects a change in the oscillation frequency output before and after the body is detected. This is then amplified to larger than 2,000%, transformed into digital signals, and delivered to exclusive software to compare and search for embedded data. The detection time followed by the touch area of the body standard to a $12.8{\emptyset}$ magnetic field coil was 30% contrast at 0.08sec and 80% contrast at 0.03sec, in which the detection distance was 13.4mm, showing the best level.

Foreign Body Reaction after Implantation of a Device for Intervertebral Assisted Motion

  • Seo, Jun-Yeong;Ha, Kee-Yong;Kim, Young-Hoon;Ahn, Joo-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.647-649
    • /
    • 2016
  • The device for intervertebral assisted motion (DIAM) is a dynamic implant that consists of a silicone bumper enveloped by a polyethylene terephthalate (PET) fiber sack. Silicone and PET were used because of their biological inertness, but repetitive motion of the spine can cause wear on the implant nonetheless. The purpose of this study is to report a case of foreign body reaction (FBR) against a DIAM. A 72-year-old female patient presented with lower back pain and both legs radiating pain. She had undergone DIAM implantation at L4-5 for spinal stenosis 5 years previously. The intervertebral disc space of L4-5, where the DIAM was inserted, had collapsed and degenerative scoliosis had developed due to left-side collapse. MRI showed L3-4 thecal sac compression and left L4-5 foraminal stenosis. The patient underwent removal of the DIAM and instrumented fusion from L3 to L5. During surgery, fluid and granulation tissue were evident around the DIAM. Histopathology showed scattered wear debris from the DIAM causing chronic inflammation due to the resulting FBR. A FBR due to wear debris of a DIAM can induce a hypersensitivity reaction and bone resorption around the implant, causing it to loosen.

Development of body position sensor device for posture correction training (자세 교정훈련을 위한 체위 변환 감지 센서 디바이스의 개발)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2020
  • Recently the incidence of musculoskeletal disorders in students and office workers is increasing, and the necessity of maintaining correct posture and corrective training is required, but related research is insufficient. In the previous study, a membrane sensor or a pressure sensor was placed on the seat cushion to see the deviation of the body weight, or a sensor that restrained the user was attached to measure the position change. In this study, a sensor device for detecting a position change in consideration of wearing comfort was developed, and the measured angle was verified through an analysis app. A sensor device consisting of an IMU sensor is attached to the cervical spine and vertebra spine to measure the position transformation in the sitting position. The change value of the position measured by the two sensors was converted into an angle, and the angle value is displayed in real time through the analysis app. In this study, the possibility of measuring the real-time change value according to the change in position, the convenience of wearing, and the tendency of angle measurement were proved. Future research should proceed with more precise angle calculation and correction of motion noise.

Dynamic characteristics between waves and a floating cylindrical body connected to a tension-leg mooring cable placed in a simulated offshore environment

  • Song, Juhun;So, Soo-Hyun;Lim, Hee-Chang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.4
    • /
    • pp.375-385
    • /
    • 2016
  • Given the rapid progress made in understanding the dynamics of an offshore floating body in an ocean environment, the present study aimed to simulate ocean waves in a small-sized wave flume and to observe the motion of a cylindrical floating body placed in an offshore environment. To generate regular ocean waves in a wave flume, we combined a wave generator and a wave absorber. In addition, to precisely visualise the oscillation of the body, a set of light-emitting diode illuminators and a high-speed charge-coupled device camera were installed in the flume. This study also focuses on the spectral analysis of the movement of the floating body. The wave generator and absorbers worked well to simulate stable regular waves. In addition, the simulated waves agreed well with the plane waves predicted by shallow-water theory. As the period of the oncoming waves changed, the movement of the floating body was substantially different when tethered to a tension-leg mooring cable. In particular, when connected to the tension-leg mooring cable, the natural frequency of the floating body appeared suddenly at 0.391 Hz as the wave period increased.

The Effect of Water-Filtered Infrared-A (wIRA) on Body Core and Body Surface Temperatures in Anesthetized Rabbits Maintained with Isoflurane

  • Geonho Choi;Dongseok Kim;Eungmo Tae;Ilgwon Jung;Sang-Kwon Lee;Won-Jae Lee;Sung-Ho Yun;Young-Sam Kwon;Min Jang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.1
    • /
    • pp.44-49
    • /
    • 2023
  • The purpose of this study was to evaluate body temperature changes in rabbits anesthetized using water-filtered infrared-A (wIRA). Ten rabbits were used for this study. For the experimental group (wIRA group; wG, n = 5), the experimental equipment was used and irradiated using wIRA. The control group (CG, n = 5) did not have any warming device. There were no significant differences in heart rate, respiration rate, and end tidal CO2 (EtCO2) between wG and CG. After 80 min, the core body temperature of wG rabbits was significantly higher than that of CG rabbits. The surface body temperature was significantly higher while receiving wIRA support at all time points after 5 min. In conclusion, in rabbits under inhalation anesthesia, the surface body temperature was better maintained than the core body temperature when using wIRA.

Development and Evaluation of Smart Jacket with Embedded Wearable Device (웨어러블 디바이스를 이용한 기능성 스마트 재킷 개발 및 평가)

  • Lee, Jeong-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.3
    • /
    • pp.395-407
    • /
    • 2008
  • As global interest in clothing spreads over the smart clothing which arouses high added-value in the apparel industry, this study is to develop a smart jacket with an electrically-vibrating device maintaining excellent appearance and comfort. The vibrating device has a massage function that could relieve muscle pain near shoulders and neck. The purposes of this research are to develop jacket pattern for men in their thirties considering body shapes and fashion trend, to develop a wearable device that is composed of motor and controller and integrate it into a jacket, and to assess the external appearance and functional satisfaction of the smart jacket through the wearing test. The results are as follows: 1. In order to develope an appropriate jacket pattern for men in their thirties, several patterns were assessed for their fitting comfort. The final pattern was completed after making alterations some parts, and showed high satisfaction as 3.6(on a five-point scale) in all categories. 2. A vibrating device was developed by connecting motor, controller, battery and switch. Developing this device, focus was maximizing the strength of motor and minimizing the heat generated from motor and controller. Snaps were placed between inner and outer cloth of jacket so that the vibrating device could be easily attachable and detachable. The motor was located around Trapezius where muscles often get stiff. A switch was designed to be used in selecting the modes of Strong, Weak, and Cross Tapping. 3. The wearing test was conducted to examine outer appearance, comfort for motion, and functionality of the smart jacket. The results of assessing outer appearance showed that the location for attaching the vibrating device was not noticeable but looked natural, and there is almost no change in outer appearance when the vibrating device operates. The result of assessing comfort of action revealed that wearer's satisfaction was high in all categories about activity, wearer's comfort, etc. The result also showed that wear's satisfaction for effects of vibrating massage, easiness in using the device, heat generation was not less than 3.5 in all categories except a category about noise.

Highly Manufacturable 65nm McFET (Multi-channel Field Effect Transistor) SRAM Cell with Extremely High Performance

  • Kim, Sung-Min;Yoon, Eun-Jung;Kim, Min-Sang;Li, Ming;Oh, Chang-Woo;Lee, Sung-Young;Yeo, Kyoung-Hwan;Kim, Sung-Hwan;Choe, Dong-Uk;Suk, Sung-Dae;Kim, Dong-Won;Park, Dong-Gun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2006
  • We demonstrate highly manufacturable Multi-channel Field Effect Transistor (McFET) on bulk Si wafer. McFET shows excellent transistor characteristics, such as $5{\sim}6 times higher drive current than planar MOSFET, ideal subthreshold swing, low drain induced barrier lowering (DIBL) without pocket implantation and negligible body bias dependency, maintaining the same source/drain resistance as that of a planar transistor due to the unique feature of McFET. And suitable threshold voltage ($V_T$) for SRAM operation and high static noise margin (SNM) are achieved by using TiN metal gate electrode.

Development of energy expenditure measurement device based on voice and body activity (음성과 활동량을 이용한 에너지 소모량 측정기기 개발)

  • Im, Jae Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.303-309
    • /
    • 2012
  • Energy expenditure values were estimated based on the voice signals and body activities. Voice signals and body activities were obtained using PVDF contact vibration sensor and 3-axis accelerometer, respectively. Vibration caused by voices, activity signals, and actual energy consumption were acquired using data acquisition system and gas analyzer. With the use of power values from the voice signals and weight as independent variables, R-square of 0.918 appeared to show the highest value. For activity outputs, use of signal vector magnitude, body mass index, height, and age as independent variables revealed to provide the highest correlation with actual energy expenditure. Estimation of energy expenditure based on voice and activity provides more accurate results than based on activity only.

The Effect of Visual Feedback on One-hand Gesture Performance in Vision-based Gesture Recognition System

  • Kim, Jun-Ho;Lim, Ji-Hyoun;Moon, Sung-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.551-556
    • /
    • 2012
  • Objective: This study presents the effect of visual feedback on one-hand gesture performance in vision-based gesture recognition system when people use gestures to control a screen device remotely. Backgroud: gesture interaction receives growing attention because it uses advanced sensor technology and it allows users natural interaction using their own body motion. In generating motion, visual feedback has been to considered critical factor affect speed and accuracy. Method: three types of visual feedback(arrow, star, and animation) were selected and 20 gestures were listed. 12 participants perform each 20 gestures while given 3 types of visual feedback in turn. Results: People made longer hand trace and take longer time to make a gesture when they were given arrow shape feedback than star-shape feedback. The animation type feedback was most preferred. Conclusion: The type of visual feedback showed statistically significant effect on the length of hand trace, elapsed time, and speed of motion in performing a gesture. Application: This study could be applied to any device that needs visual feedback for device control. A big feedback generate shorter length of motion trace, less time, faster than smaller one when people performs gestures to control a device. So the big size of visual feedback would be recommended for a situation requiring fast actions. On the other hand, the smaller visual feedback would be recommended for a situation requiring elaborated actions.