• 제목/요약/키워드: Non Destructive Test

검색결과 473건 처리시간 0.029초

Bendable 임베디드 전자모듈의 손상 메커니즘 (Failure Mechanism of Bendable Embedded Electronic Module Under Various Environment Conditions)

  • 조윤성;김아영;홍원식
    • Journal of Welding and Joining
    • /
    • 제31권5호
    • /
    • pp.59-63
    • /
    • 2013
  • A bendable electronic module has been developed for a mobile application by using a low-cost roll-to-roll manufacturing process. In flexible embedded electronic module, a thin silicon chip was embedded in a polymer-based encapsulating adhesive between flexible copper clad polyimide layers. To confirm reliability and durability of prototype bendable module, the following tests were conducted: Moisture sensitivity level, thermal shock test, high temperature & high humidity storage test, and pressure cooker tester. Those experiments to induce failure of the module due to temperature variations and moisture are the experiment to verify the reliability. Failure criterion was 20% increase in bump resistance from the initial value. The mechanism of the increase of the bump resistance was analyzed by using non-destructive X-ray analysis and scanning acoustic microscopy. During the pressure cooker test (PCT), delamination occurred at the various interfaces of the bendable embedded modules. To investigate the failure mechanism, moisture diffusion analysis was conducted to the pressure cooker's test. The hygroscopic characteristics of the encapsulating polymeric materials were experimentally determined. Analysis results have shown moisture saturation process of flexible module under high temperature/high humidity and high atmosphere conditions. Based on these results, stress factor and failure mechanism/mode of bendable embedded electronic module were obtained.

고강도콘크리트 벽체부재에 접합분리 시험체를 활용한 강도관리에 관한 연구 (Compressive Strength Control of High Strength Concrete Structure Using Samples with Isolated Junction Test)

  • 기전도;김학영;김광기;백민수;임남기;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.47-50
    • /
    • 2009
  • The existing techniques used to estimate and manage the compressive strength of concrete do not include the environmental factors that influence the development of compressive strength and the compressive strength itself. Thus, it is necessary to develop a reasonable yet simple way to measure the compressive strength of concrete structures at construction sites by considering concrete's mechanical properties and curing environment. This study was conducted to propose an acrylic form and a junction isolation mold with crack-inducing boards that uses non-destructive methods to create and collect concrete test samples that are cured in the same condition as the actual concrete structures. junction isolation molds were used in high-strength and super high-strength concrete to evaluate the reliability of compressive strength evaluation on the test sample. The following were the findings of this study:

  • PDF

탄성파시험의 이동성 확보를 위한 마이크로폰 센서의 활용 (Utilization of a Microphone to Acquire Mobility in Seismic Testing)

  • 조성호;부카리;노리나
    • 대한토목학회논문집
    • /
    • 제33권4호
    • /
    • pp.1509-1521
    • /
    • 2013
  • 구조물의 안정성에 대한 사회적 요구는 이를 충족시키기 위한 기술발전으로 이어지게 되었고, 지각구조를 이해하기 위해 개발된 탄성파기법도 구조물의 건전성을 평가하는 비파괴 기법으로 자리매김하게 되었다. 비파괴 탄성파기법의 핵심은 측정대상 매질의 탄성파 속도를 측정하는 것으로, 탄성파의 전파를 측정하는 센서를 필수적으로 사용하여야 한다. 기존의 탄성파기법은 접촉식 센서를 사용하기 때문에 이동중 연속시험이 불가능한 문제점이 있었고, 탄성파 시험의 효율성이 실용적 요구조건에 부합하지 못하는 한계성이 있었다. 본 연구에서는 비접촉식 센서의 일종인 보급형 마이크로폰을 센서로 활용하여 기존 탄성파 시험의 문제점을 극복하고자 하는 연구를 수행하였다. 다짐지반의 실시간 다짐품질 확인, 콘크리트 구조물의 재료강성 및 내부결함의 확인 등을 위한 표면파 시험과 공진시험 등을 마이크로폰 활용대상으로 설정하였고, 마이크로폰센서의 영향인자 연구, 실구조물에 대한 현장시험 등을 수행하였다. 이를 통하여 마이크로폰 센서의 신뢰성과 효율성을 확인할 수 있었으며, 최적의 마이크로폰 활용방안을 제안하였다.

압분광법을 이용한 강재의 비접촉식 응력측정 (Non-contact Stress Measurement in Steel Member using Piezospectroscopy)

  • 김종우;김남규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권3호
    • /
    • pp.92-95
    • /
    • 2019
  • 본 논문에서는 압분광법을 기반으로 강재에 작용하는 응력을 비파괴/비접촉식으로 측정할 수 있는 새로운 방법은 제안하고, 이에 대한 가능성을 실험적으로 검증하였다. 분광법은 일반적으로 대상물의 화학적 성분을 분석하는데 주로 사용되며, 토목분야에서는 강재의 부식을 판단하는데 일부 사용되고 있다. 압분광법은 대상물이 하중을 받을 때 측정된 스펙트럼이 하중이 없는 상태에서 측정된 스펙트럼으로부터 이동(Shift)되는 현상인, 압분광현상을 기반으로 응력을 측정하는 방법이다. 여기서, 응력-스펙트럼 이동 관계를 선형으로 가정하였을 때, 압분광 계수를 도출할 수 있으며, 이를 통하여 현재상태의 응력을 측정할 수 있다. 해당 기술은 레이저를 기반으로한 비접촉식 응력측정 기술로써, 최근에 철도 구조물에 대한 응력 측정을 시작으로 다양한 토목구조물의 응력측정에 대한 적용이 시도되고 있다. 본 연구에서는 이와 같은 압분광법 기술을 이용하여 강구조물의 응력을 측정할 수 있도록, 용사코팅을 이용하여 알루미나를 구조용 강재표면에 도포하고, 일축압축 하중시험을 수행하여 각 하중단계에서의 스펙트럼 이동(Shift)값을 확인하였다. 이를 통하여, 각 하중값과 스펙트럼 이동값이 선형관계임을 확인하였다. 따라서, 이와 같은 선형적인 관계로 부터, 1차 선형식의 상수값인 압분광 계수를 도출하고, 이를 통하여 강재에 작용하는 응력을 측정할 수 있을 것으로 기대된다.

구조물의 안전진단을 위한 충격파의 주파수 영역 탐사에 관한 연구 (A study about frequency domain analysis of impact-wave for detecting of structural defects in the concrete structure)

  • 서백수;김훈;김형준;이상철
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 공동학술대회 논문집
    • /
    • pp.165-180
    • /
    • 2005
  • 충격탄성파 검사법은 콘크리트 구조물 내부의 결함과 외부 표면 사이에서 반사되어 전파되는 응력파를 이용한 비파괴 시험 방법이다. 본 연구에서 토목 구조물의 안전진단을 위하여 충격탄성파 검사법을 이용한 비파괴 시험을 수행하였다. 이를 위해서 토모그래피 방식을 이용한 투과법, 크로스 홀 방식을 이용한 투과법 그리고 일반적으로 터널라이닝과 같은 1차원 면에서 사용되는 반사법을 적용해 그 결과를 비교${\cdot}$분석하였다.

  • PDF

중심축압(中心軸壓)을 받는 콘크리트충전(充塡) 각형강관(角形鋼管)기둥의 내력(耐力)에 관한 실험적(實驗的) 연구(硏究) (Experimental Study on Compressive Strength of Centrally Loaded Concrete Filled Square Tubular Steel Columns)

  • 김종성;오윤태;권영환
    • 한국강구조학회 논문집
    • /
    • 제8권4호통권29호
    • /
    • pp.59-76
    • /
    • 1996
  • Concrete filled steel tube column has a large load carrying capacity through its steel and concrete interaction which makes it useful in construction. However, it has not been used often in a practical construction field. This is partly due to the non-destructive inspection method for concrete filling which has yet to be established. Furthermore, there are the lack of test data and a practical method in evaluating the ultimate load carrying capacity of concrete filled steel tube column. This paper will attempt to predict the ultimate strength of short concrete filled square tubular steel columns through conducting several tests. To accumulate the new test data on concrete filled steel tube columns, a total of 42 specimens of steel tubular columns were monotonically tested under concentric axial force, having the slenderness ratio(${\lambda}=10,\;15,\;20$), width-thickness ratio(d/t=25.0, 33.3) and concrete strengths($F_{c}=210,\;240,\;270kg/cm^{2}$). The hollow sections and concrete filled steel columns were compared to check the lateral confinded effects by steel tube. Through these test results, we propose a coefficient k=3.64 for the strength evaluation formula(10) of concrte filled tubular steel short columns.

  • PDF

연속음향감지기법을 이용한 긴장력이 감소된 10 m PSC보의 PS 강선 파단음파 감지 (Detection of Fracture Signals of Low Prestressed Steel Wires in a 10 m PSC Beam by Continuous Acoustic Monitoring Techniques)

  • 윤석구;이창노
    • 콘크리트학회논문집
    • /
    • 제22권1호
    • /
    • pp.113-122
    • /
    • 2010
  • 후 긴장된 PS 강재의 부식과 파단은 프리스트레스 콘크리트 교량의 안전에 매우 심각한 문제를 발생시키고 있다. 따라서 교량의 내하력 평가시 PS 강재의 부식 상태를 조사해야 하며, 부식된 PS 강재가 발견되는 경우, 부식에 의한 강재의 단면적 감소량을 극한강도 평가시 고려해야만 한다. 선행 연구에서는 연속음향감지기법을 그라우팅되고 후 긴장된 PS 강연선의 부식과 파단을 감지할 수 있는 신뢰할 만한 비파괴검사방법으로 평가하였다. 이 연구에서는 긴장재에 도입된 응력 수준이 현행 설계기준에 제시된 수준보다 낮게 도입된 PS 강연선에 대해 부식에 의한 강선 파단을 감지하기 위한 실험적 연구를 수행하였다. 이를 위해 프리스트레스의 크기가 각각 인장강도의 66%와 40%로 도입된 PS 강연선이 포함된 길이 10 m의 PSC 보를 제작하였다. 부식 촉진 장비를 이용하여 긴장재를 인위적으로 부식시켰으며, 7개의 음향센서와 연속음향감지장치를 이용하여 실험부재를 모니터링하였다. 부식 촉진 실험 동안 각 PS 강연선으로부터 2번의 강선 파단음파를 성공적으로 감지하였으며, 또한 오차범위 20 mm 이하로 음원 위치를 표정할 수 있었다. 이상의 실험 결과를 토대로 그라우팅되고 후 긴장된 PSC 보에서 발생되는 PS 강선 파단을 감지하는데 연속음향감지기법을 적용할 수 있다고 판단된다.

실내실험과 수치해석을 이용한 암반지보구조물의 응력거동 분석을 위한 기초 연구 (Preminary Study on Stress Analysis of Rock-mass Support Structure using Laboratory Test and Numerical Simulation)

  • 이재호;문홍득;유지형;김혁;손영주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.825-831
    • /
    • 2010
  • In this study is stress behavior of steel support structure is to identify basic research. Steel stress due to load step to determine the behavior of steel using strain gauge steel loading test was performed. Numerical analysis and steel loading test using strain gauge on the actual steel stress behavior was analyzed. First, when tensile loading 3.5tonf load side of the plastic behavior appeared. Elastic model, using numerical analysis and comparison of results, the actual value is saved and you can see some difference. This repeated loading tests on steel can be seen from the results of the stress behavior of the steel rather than the elastic behavior of elastic-plastic behavior is because you can see. In addition, the upper and lower steel stress in compression and tension behavior represents the behavior was similar, but different. Steel loading test results, Y-axis get a compression if X-axis is tension. The future based on this study, the stress sensitivity curve of magnetic anisotropy sensor for non-destructive stress measurement technique for the study will be performed. And the behavior of plastic zone and residual stress to determine the numerical analysis using non-elastic model is needed.

  • PDF

고온을 받은 콘크리트 적용을 위한 초음파 속도를 이용한 강도추정식 검토 (Study on the Compressive Strength Equation using Ultrasonic Pulse Velocity with Concrete Exposed to High Temperature)

  • 황의철;김규용;최경철;윤민호;이보경;이영욱
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.139-140
    • /
    • 2015
  • The purpose of this study was to evaluate existing compressive strength equation with concrete exposed to high temperature by ultrasonic pulse velocity. As the result, original compressive strength equation is proper only for compressive strength of normal concrete. Therefore, an accumulation of experimental database of concrete exposed to high temperature is necessary for proposal of new compressive strength equation.

  • PDF

재생골재콘크리트의 공학적 특성에 미치는 재생골재 혼합조건의 영향에 관한 실험적 연구(제2보 경화콘크리트의 성상 및 비파괴 시험 적용성에 관하여) (An Experimental Study on the Replacement Proportion of Recycled Aggregate Effecting on the Engineering Properties of Recycled Concrete)

  • 남상일;이상수;류광일;박정일;김진만;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 봄 학술발표회 논문집
    • /
    • pp.22-25
    • /
    • 1993
  • The study of recycled aggregate concrete in which demolition waste is utilized to produce aggregate for new concrete, can contribute to the solution of two problems, The first is the shortage of aggregate from river, and the second is the waste disposal problem. In comparison with natural aggregate concrete, recycled aggregate concrete shows reductions in compressive strength , tensile strength, vending strength , shear strength and increases in drying shrinkage and creep. Recycled aggregate concrete may also be less durable due to increase in porosity and permeability. The purpose of this study is to investigate and analyze the variation of engineering properties according to replacement proportion of recycled aggregates and applicability of non-destructive test in the gardened recycled concrete.

  • PDF