• Title/Summary/Keyword: Nano Stage

Search Result 280, Processing Time 0.032 seconds

Comparative study on the effects of micro- and nano-sized zinc oxide supplementation on zinc-deficient mice

  • Ja-Seon Yoon;Sang Yoon Nam;Beom Jun Lee;Hyun Jik Lee
    • Journal of Veterinary Science
    • /
    • v.24 no.1
    • /
    • pp.3.1-3.13
    • /
    • 2023
  • Background: Zinc (Zn) is an essential cofactor for physiological homeostasis in the body. Zn oxide (ZnO), an inorganic compound that supplies Zn, exists in various sizes, and its bioavailability may vary depending on the size in vivo. However, comparative studies on the nutritional effects of micro-sized ZnO (M-ZnO) and nano-sized ZnO (N-ZnO) supplementation on Zn deficiency (ZnD) animal models have not been reported. Objectives: This study investigated the nutritional bioavailability of N-ZnO and M-ZnO particles in dietary-induced ZnD mice. Methods: Animals were divided into six experimental groups: normal group, ZnD control group, and four ZnO treatment groups (Nano-Low, Nano-High, Micro-Low, and MicroHigh). After ZnD induction, N-ZnO or M-ZnO was administered orally every day for 4 weeks. Results: ZnD-associated clinical signs almost disappeared 7 days after N-ZnO or M-ZnO administration. Serum Zn concentrations were higher in the Nano-High group than in the ZnD and M-ZnO groups on day 7 of ZnO treatment. In the liver and testis, Nano-Low and Nano-High groups showed significantly higher Zn concentrations than the other groups after 14-day treatment. ZnO supplementation increased Mt-1 mRNA expression in the liver and testis and Mt-2 mRNA expression in the liver. Based on hematoxylin-and-eosin staining results, N-ZnO supplementation alleviated histological damage induced by ZnD in the testis and liver. Conclusions: This study suggested that N-ZnO can be utilized faster than M-ZnO for nutritional restoration at the early stage of ZnD condition and presented Mt-1 as an indicator of Zn status in the serum, liver, and testis.

Optimal design of a flexure hinge-based XY AFM scanner for minimizing Abbe errors and the evaluation of measuring uncertainty of AFM system (원자현미경용 XY 스캐너의 아베 오차 최소화를 위한 최적 설계 및 원자 현미경의 측정 불확도 평가)

  • Kim D.M.;Lee D.Y.;Gweon D.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1438-1441
    • /
    • 2005
  • To establish of standard technique of nano-length measurement in 2D plane, new AFM system has been designed. In this system, measurement uncertainty is dominantly affected by the Abbe error of XY scanning stage. No linear stage is perfectly straight; in other words, every scanning stage is subject to tilting, pitch and yaw motion. In this paper, an AFM system with minimum offset of XY sensing is designed. And XY scanning stage is designed to minimize rotation angle because Abbe errors occur through the multiply of offset and rotation angle. To minimize the rotation angle optimal design has performed by maximizing the stiffness ratio of motion direction to the parasitic motion direction of each stage. This paper describes the design scheme of full AFM system, especially about XY stage. Full range of fabricated XY scanner is $100um\times{100um}$. And tilting, pitch and yaw motion are measured by autocollimator to evaluate the performance of XY stage. Using this AFM system, 3um pitch specimen was measured. As a result, the uncertainty of total system has been evaluated.

  • PDF

Position Control of a Precise 6-D.O.F Stage with Magnetic Levitation (자기부상을 이용한 초정밀 6자유도 스테이지의 위치제어)

  • 이세한;강재관;김용주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.894-897
    • /
    • 2004
  • In this paper, we address a position control scheme for a stage system, which is levitated and driven by electric magnetic actuators. This consists of a levitating object (called platen) with 4 permanent magnetic linear synchronous motors in parallel. Each motor generates vertical force for suspension against gravity and propulsion force horizontally as well. This stage can generate six degrees of freedom motion by the vertical and horizontal forces. Dynamic equations of the stage system are derived based on Newton-Euler method and its special Jacobian matrix describing a relation between the Joint velocity and platen velocity is done. There are proposed two control schemes for positioning, which are Cartesian space controller and Joint space controller. The control performance of the Cartesian space controller is better than the Joint space controller in task space trajectory while the Joint space controller is simpler than the Cartesian space controller in controller realization.

  • PDF

Study on the Air-bearing Stage Driven by Linear Induction Motors (선형 유도기 구동 방식 공기 베어링 스테이지에 관한 연구)

  • Jung, Kwang-Suk;Shim, Ki-Bon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.6
    • /
    • pp.39-46
    • /
    • 2010
  • Linear induction motor is adopted as an actuator of the planar stage. An inherently poor characteristic at zero or ultra-low speed zone of the induction motor is remarkably improved due to a recent development of power electronic semiconductor technology and a spatial vector control theory. At present, a servo response speed of the induction motor reaches 90 percent of one of PM synchronous or BLDC motor. Specially, as a secondary of the induction motor can be constructed using uniform conducting sheets, there is no periodic force ripple as in PM motors. So, the induction motor can be superior to another driving means under a certain condition. This paper discusses the overall development procedure of non-contact planar stage with a big workspace using linear induction motors.

The Design of BCM based Power Factor Correction Control IC for LED Applications (LED 응용을 위한 BCM 방식의 Power Factor Correction Control IC 설계)

  • Kim, Ji-Man;Jung, Jin-Woo;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2707-2712
    • /
    • 2011
  • In this paper, a power factor correction (PFC) control circuit using single stage boundary conduction mode(BCM) for the 400V. 120W LED drive application has been designed. The proposed control circuit is aimed for improvement of the power factor correction and reduction of the total harmonic distortion. In this circuit, a new CMOS multiplier structure is used instead of a conventional BJT(bipolar junction transistor) based multiplier where has a relatively large area. The CMOS multiplier can bring 30 % reduced chip area, competitive die cost in comparison with the conventional BJT multiplier.

Characteristics of Oxide Layers Formed on Al2021 Alloys by Plasma Electrolytic Oxidation in Aluminate Fluorosilicate Electrolyte

  • Wang, Kai;Koo, Bon-Heun;Lee, Chan-Gyu;Kim, Young-Joo;Lee, Sung-Hun;Byon, Eung-Sun
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.6
    • /
    • pp.308-311
    • /
    • 2008
  • Oxide layers were prepared on Al2021 alloys substrate under a hybrid voltage of AC 200 V (60 Hz) combined with DC 260 V value at room temperature within $5{\sim}60\;min$ by plasma electrolytic oxidation (PEO). An optimized aluminate-fluorosilicate solution was used as the electrolytes. The surface morphology, thickness and composition of layers on Al2021 alloys at different reaction times were studied. The results showed that it is possible to generate oxide layers of good properties on Al2021 alloys in aluminate-fluorosilicate electrolytes. Analysis show that the double-layer structure oxide layers consist of different states such as ${\alpha}-{Al_2}{O_3}$ and ${\gamma}-{Al_2}{O_3}$. For short treatment times, the formation process of oxide layers follows a linear kinetics, while for longer times the formation process slows down and becomes a steady stage. During the PEO processes, the average size of the discharge channels increased gradually as the PEO treatment time increased.

Optimal Design of Controller for Ultra-Precision Plane X-Y Stage (초정밀 평면 X-Y 스테이지의 최적제어기 설계)

  • Kwak, L. K.;kim, J. Y.;Yang, D. J.;Ko, M. S.;You, S.;Kim, K. T.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.342-347
    • /
    • 2002
  • After the industrial revolution in 20 century, the world are preparing for new revolution that is society with knowledge for a basis such as IT(Information Technology), NT(Nano Technology) and BT(Bio Technology). Recently, NT is applied to various fields that are composed of science, industry, media and semiconductor-micro technology. It has need of IT that is ultra-precision positioning technology with strokes of many hundreds mm and maintenance of nm precision in fields of ultra micro process, ultra precision measurement, photo communication part and photo magnetic memory. Performance test of servo control system that is used ultra-precision positioning system with single plane X-Y stage is performed by simulation with Matlab. Analyzed for previous control algorithm and adapted for modern control theory, dual servo algorithm is developed by minimum order observer, and stability and priority on controller are secured. Through the simulation and experiments on ultra precision positioning, stability and priority on ultra-precision positioning system with single plane X-Y stage and control algorithm are secured by using Matlab with Simulink and ControlDesk made in dSPACE

  • PDF

Prostaglandins Involving in Blastocyst Development through Calcium Mediated Signaling Pathway

  • Lee, Ja-Myong;Kwon, Hyuck-Chan;Lee, Seung-Jea;Cheon, Yong-Pil
    • Development and Reproduction
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Lipid metabolites involved in cellular regulation as signaling mediators. Prostaglandins (PGs), metabolites of lipid are involved to pregnancy at the time of implantation but the functional roles of PGs on embryo development are still controversy and largely unknown. In previous report, the levels of $PGE_2$ and $PGF_{2a}$ at embryos of morula stage and blastocyst stage were explored (Cheon et al., 1998). In this study, the previous suggestion was confirmed and the possible downstream mediator of prostaglandin $E_2$ and prostaglandin $F_{2a}$ on the expansion and hatching of mouse embryo was examined. As expected, developmental rate of the blastocyst to expanded stage was a concentration-response curve that showed the highest expansion rate at 10 ${\mu}M$ $PGE_2$, but at 100 ${\mu}M$ $PGE_2$, the rate was decreased. In contrast to the $PGE_2$, $PGF_{2a}$ stimulated expansion without toxicity at highest concentration. Cotreatment of PGs with indomethacin overcame the inhibitory effects of indomethacin in expansion. Exogenous PGs also improved the development of expanded embryos to the hatching stage. Besides, PGs receptors' transcripts detected at blastocyst. $PGE_2$ was caused of calcium fluctuation in the blastocyst but $PGF_{2a}$ did not. The changes of intracellular calcium concentration were different between indomethacin pretreated embryos and non-treated embryos. Based on these results it is suggested that PGs work as paracrine and/or autocrine factors through calcium and the others which were not identified in this study.

Experiments of a Novel Magnetic Levitation Stage for Wide Area Movements

  • Jeon, Jeong-Woo;Caraiani, Mitica;Oh, Hyeon-Seok;Kim, Sung-Shin
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.558-563
    • /
    • 2012
  • In this paper, a novel planar type magnetic levitation system without other assistant devices is proposed and it can move with 6 degree of freedom (X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$) in wafer size as well as in nano scale positioning.The mover is composed with 2-D Halbach permanent magnet array and the stator is composed with $10{\times}10$ coil arrays.It was composed in laboratory and tested with short stroke (4 [mm]) and long stroke (160 [mm])movements. The errors of short movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}3urad$, ${\pm}2urad$, ${\pm}1urad$]The errors of long stroke movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}1.5urad$, ${\pm}2urad$, ${\pm}0.5urad$].