• 제목/요약/키워드: Multiplexed detection

검색결과 45건 처리시간 0.025초

식품 유래 박테리아 현장검출용 바이오센서 (Biosensors for On-the-spot Detection of Bacteria from Foods)

  • 이원일;김보영;손영민;김아리;이내응
    • 센서학회지
    • /
    • 제25권5호
    • /
    • pp.354-364
    • /
    • 2016
  • Recently there have been extensive research activities on the development of on-the-spot detection technologies for bacteria from foods due to growing high demand for food safety. In particular, on-the-spot detection devices using biosensors with rapid, highly sensitive and multiplexed sensing capability are promising for portable or mobile applications. Firstly, issues related to on-the-spot bacteria detection are discussed. Then, detection methods for bacteria, types of biosensors depending on transducing principle and receptors, and platforms for integration of biosensors and signal readers are reviewed. Finally, prospects for development of on-the-spot detection devices are summarized.

ML검출 기반 공간다중화 MIMO 시스템의 UEP 프리코더 선정기술 (UEP Precoder Selection Technique for ML Detected SM MIMO Systems)

  • 박재영;김재권
    • 한국통신학회논문지
    • /
    • 제42권4호
    • /
    • pp.747-749
    • /
    • 2017
  • 본 논문에서는 maximum-likelihood (ML) 신호검출을 사용하는 공간다중화 multiple-input multiple-output (MIMO) 시스템을 위한 새로운 unequal error protection (UEP) 프리코더 선정기술을 제안한다. 기존 프리코더 선정기술들은 UEP를 고려하지 않고 설계되었으나, 제안된 기술은 다중안테나 UEP를 고려한다. 모의실험을 통해 제안된 기술의 적용에 따른 향상된 다중안테나 UEP 성능을 확인한다.

공간다중화 MIMO 시스템을 위한 QOC 신호검출 기법 (A QOC Signal Detection Method for Spatially Multiplexed MIMO Systems)

  • 임태호;김재권;조용수
    • 한국통신학회논문지
    • /
    • 제35권9C호
    • /
    • pp.771-777
    • /
    • 2010
  • 본 논문은 공간다중화 multiple input multiple output (MIMO) 시스템을 위한 새로운 신호검출 기법인 QR-OSIC with Candidates (QOC) 기법을 제안한다. 제안하는 QOC 기법은 부분적인 successive interference cancellation (SIC) 알고리즘과 maximum likelihood (ML) metric 연산을 이용하여 많은 수의 후보 심볼 벡터 없이 최적 성능과 유사한 성능을 얻는다. 제안된 QOC 기법은 hard, soft decoding 시스템에서 모두 동일한 알고리즘으로 변경없이 사용할 수 있다. 특히, soft decoding 시스템을 위한 송신 신호의 모든 비트의 log likelihood ratio (LLR)을 기존 LLR estimation 알고리즘 없이 효율적으로 생성 가능하다. 제안된 신호검출 기법은 고정된 연산복잡도를 가지며 파이프라인 구조로도 구현이 가능하므로 VLSI 구현에 효율적인 특성을 보인다. $4{\times}4$ 16-QAM MIMO 시스템을 위한 신호검출 기법을 VLSI 구현을 통하여 비교한 결과 QOC 신호검출기가 K-Best 신호검출기에 비해 27% 크기를 가지면서 하드웨어 지연은 더욱 작은 것을 확인 할 수 있다.

공간다중화 MIMO 시스템을 위한 MML-DFE기법의 FPGA 구현 (An FPGA Implementation of an MML-DFE for Spatially Multiplexed MIMO Systems)

  • 임태호;이규인;박창환;정기철;유성욱;김재권;조용수
    • 한국통신학회논문지
    • /
    • 제31권11A호
    • /
    • pp.1167-1175
    • /
    • 2006
  • ML-DFE(Maximum Likelihood-Decision Feedback Equalization) 기법은 V-BLAST와 같은 공간다중화 MIMO시스템에서 ML 기법의 구현 복잡도를 줄이기 위한 준 최적 신호검출기법으로 불 수 있다. ML-DFE 기법은 ML 기법과 DFE 기법을 결합하여 오차전파를 줄이면서 rich scattering 환경에서 높은 다이버시티 이득을 얻을 수 있다. 본 논문에서는 ML-DFE 기법과 동일한 성능을 보이면서 연산복잡도를 줄일 수 있는 MML-DFE(Modified Maximum Likelihood - Decision Feedback Equalization) 기법을 제안한다. 또한 FPGA 구현을 통하여 제안된 MML-DFE 기법이 기존 ML-DFE 기법에 비하여 구현복잡도를 크게 감소시키면서 동일한 성능을 유지함을 확인한다.

협력적 공간다중화 기반 상향링크 다중사용자 시스템을 위한 신호검출 기법 (A Signal Detection Method for Uplink Multiuser Systems Based on Collaborative Spatial Multiplexing)

  • 임태호;김영준;정재훈;조용수
    • 한국통신학회논문지
    • /
    • 제35권2C호
    • /
    • pp.229-237
    • /
    • 2010
  • 기존 SM MIMO 시스템을 위한 신호검출 기법인 OSIC 계열의 기법과 준최적 신호검출 기법인 QRD-M 기법을 협력적 공간다중화 기반 상향링크 다중사용자 시스템에 적용할 경우 사용자별 신호의 검출성능에 차이가 발생한다. 본 논문에서는 협력적 공간다중화 기반 상향링크 다중사용자 시스템을 위한 사용자간별 검출성능 차이가 발생하지 않으면서 최적 신호검출 기법과 유사한 성능을 보이는 신호검출 기법을 제안한다. 제안된 신호검출 기법의 연산복잡도는 QPSK 변조에서는 QRD-M과 유사하지만, 16-QAM, 64-QAM과 같이 높은 차수의 변조방식의 시스템에서는 QRD-M에 비해 매우 낮은 연산복잡도를 가진다.

Nano and micro structures for label-free detection of biomolecules

  • Eom, Kil-Ho;Kwon, Tae-Yun;Sohn, Young-Soo
    • 센서학회지
    • /
    • 제19권6호
    • /
    • pp.403-420
    • /
    • 2010
  • Nano and micro structure-based biosensors are promising tool for label-free detection of biomolecular interactions with great accuracy. This review gives a brief survey on nano and micro platforms to sense a variety of analytes such as DNA, proteins and viruses. Among incredible nano and micro structure for bio-analytical applications, the scope of this paper will be limited to micro and nano resonators and nanowire field-effect transistors. Nanomechanical motion of the resonators transducers biological information to readable signals. They are commonly combined with an optical, capacitive or piezo-resistive detection systems. Binding of target molecule to the modified surface of nanowire modulates the current of the nanowire through electrical field-effect. Both detection methods have advantages of label-free, real-time and high sensitive detection. These structures can be extended to fabricate array-type sensors for multiplexed detection and high-throughput analysis. The biosensors based on these structures will be applied to lab-on-a-chip platforms and point-of-care diagnostics. Basic concepts including detection mechanisms and trends in their fields will be covered in this review.

Generalized Analysis on the Combined Effect of SPM and Fiber Chromatic Dispersion on Subcarrier Multiplexed Optical Transmission Systems for RoF Applications

  • Kim, Kyoung-Soo;Lee, Jae-Hoon;Jeong, Ji-Chai
    • Journal of the Optical Society of Korea
    • /
    • 제15권2호
    • /
    • pp.132-139
    • /
    • 2011
  • We investigate theoretically the combined effect of fiber chromatic dispersion and self-phase modulation (SPM) on multi-channel subcarrier multiplexed (SCM) optical transmission systems in terms of the detected RF carrier power and SPM-induced power gain after transmission over single-mode fiber (SMF) links. According to the calculated power gain due to the SPM effect at the transmission distance of P3dB using the detected radio-frequency (RF) carrier power after photo-detection, the power gain is significantly degraded with large optical modulation index (OMI), small SCM channel spacing, and large fiber launching power because of the increased interaction between subcarrier channels. The nonlinear phase shift due to linear and nonlinear fiber characteristics is investigated to explain these results in detail. The numerical simulation results show that the OMI per SCM channel has to be smaller than 10 % for the fiber launching power of 10 dBm to guarantee prevention of SPM-induced power gain degradation below 0.5 dB for the SCM system with the channel spacing of 100 MHz. This result is expected to be utilized for the optical transmission systems using the SCM technology in future radio-over-fiber (RoF) networks.

Applications of fiber optic sensors in civil engineering

  • Deng, Lu;Cai, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제25권5호
    • /
    • pp.577-596
    • /
    • 2007
  • Recent development of fiber optic sensor technology has provided an excellent choice for civil engineers for performance monitoring of civil infrastructures. Fiber optic sensors have the advantages of small dimensions, good resolution and accuracy, as well as excellent ability to transmit signal at long distances. They are also immune to electromagnetic and radio frequency interference and may incorporate a series of interrogated sensors multiplexed along a single fiber. These advantages make fiber optic sensors a better method than traditional damage detection methods and devices to some extent. This paper provides a review of recent developments in fiber optic sensor technology as well as some applications of fiber optic sensors to the performance monitoring of civil infrastructures such as buildings, bridges, pavements, dams, pipelines, tunnels, piles, etc. Existing problems of fiber optic sensors with their applications to civil structural performance monitoring are also discussed.

Performance of the xTAG$^{(R)}$ Gastrointestinal Pathogen Panel, a Multiplex Molecular Assay for Simultaneous Detection of Bacterial, Viral, and Parasitic Causes of Infectious Gastroenteritis

  • Claas, Eric C.;Burnham, Carey-Ann D.;Mazzulli, Tony;Templeton, Kate;Topin, Francois
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권7호
    • /
    • pp.1041-1045
    • /
    • 2013
  • The xTAG$^{(R)}$ Gastrointestinal Pathogen Panel (GPP) is a multiplexed molecular test for 15 gastrointestinal pathogens. The sensitivity and specificity of this test were assessed in 901 stool specimens collected from pediatric and adult patients at four clinical sites. A combination of conventional and molecular methods was used as comparator. Sensitivity could be determined for 12 of 15 pathogens and was 94.3% overall. The specificity across all 15 targets was 98.5%. Testing for the pathogen identified was not requested by the physician in 65% of specimens. The simultaneous detection of these 15 pathogens can provide physicians with a more comprehensive assessment of the etiology of diarrheal disease.

공간다중화 MIMO 시스템의 QRM-MLD 신호검출을 위한 개선된 탐색공간 (An Improved Search Space for QRM-MLD Signal Detection for Spatially Multiplexed MIMO Systems)

  • 허훈;우현명;양원영;방승재;박윤옥;김재권
    • 한국통신학회논문지
    • /
    • 제33권4A호
    • /
    • pp.403-410
    • /
    • 2008
  • 본 논문에서는 공간다중화 방식을 사용하는 다중 안테나 시스템의 수신부에서 사용가능한 QRM-MLD 신호검출기법을 위한 새로운 변형된 형태를 제안한다. 원래의 QRM-MLD 신호검출 기법은 채널의 QR분해 및 M-algorithm을 결합한 형태로써, ML 수신기법에 비해 상대적인 복잡도가 현저하게 낮아지면서, ML에 근접한 성능을 보이나, 전송속도를 높이기 위해 안테나 개수가 증가하거나 성상도의 크기가 증가하면 그 복잡도가 크게 증가하여 하드웨어 구현을 어렵게 하는 단점을 가지고 있다. 이러한 단점을 극복하기 위해 다양한 변형된 형태가 제안되었고, 대표적인 방법으로 성상점들을 ranking화하여 필요한 성상점에 대해서만 연산을 수행함으로써 복잡도를 감소시키는 방법이 있다. 그러나, 성상점들의 ranking화를 사용하는 QRM-MLD 방식의 성능이 원래의 QRM-MLD의 성능에 비해 현격히 저하된다. 본 논문에서는 ranking화를 사용하는 QRM-MLD의 신호검출 기법이 성능열화를 겪게 되는 이유를 분석하고, 이를 극복함으로써 새로운 변형된 형태의 QRM-MLD기법을 제안한다. 모의실험을 통해 제안된 방식의 성능을 기존 방법들과 비교하여, 제안된 방식이 원래의 QRM-MLD 신호검출방식의 성능을 달성하면서 복잡도는 ranking화를 사용하는 QRM-MLD기법과 유사하다는 것을 보인다.