• Title/Summary/Keyword: Mu Wave

Search Result 736, Processing Time 0.027 seconds

Stress Wave Technique for Detecting Decay of Structural Members in Ancient Structures

  • Lee, Jun-Jae;Oh, Jung-Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.43-50
    • /
    • 1999
  • The safety-evaluation of ancient wood structures has been executed with only visual inspection. The application of NDE(nondestructive evaluation) is required because the visual inspection has many restrictions. Among many NDE techniques, the stress wave technique was used in this research. This study focused on evaluating the extent of decay in members of ancient structures, using stress wave nondestructive technique. For application of stress wave technique to ancient structures, the threshold time which divides members into categories according to degree of decay should be determined in advance. Stress wave timer (Metriguard Model 239A) was used in this study, specimens used in this research were the members obtained from six ancient structures. All specimens were identified as Hard Pine(Pinus densiflora S. et Z. or Pinus thunbergii P.) by microscope. Each member was tested with stress wave passing radially through the pith. In this study, the stress wave time of $12{\mu}s$/cm could distinguish between sound and decayed specimens with accuracy of 77.5 percent. Also, decayed specimens could be separated into moderate and severe categories by stress wave time of $20{\mu}s$/cm. Among the three decay location groups (exterior, mixed, interior), the exterior group could be classified into sound, moderate and severe decay with the greatest accuracy. Stress wave transit time was not sensitive to small decay pockets located in interior of the member.

  • PDF

Design of the 60 GHz Single Balanced Mixer Integrated with 180° Hybrid Coupler Using MEMS Technology (HEMS 기술을 이용한 180° 하이브리드 결합기가 집적된 단일 평형 혼합기의 설계 및 제작에 관한 연구)

  • Kim Sung-Chan;Lim Byeong-Ok;Baek Tae-Jong;Ko Baek-Seok;An Dan;Kim Soon-Koo;Shin Dong-Hoon;Rhee Jin-Koo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.7 s.98
    • /
    • pp.753-759
    • /
    • 2005
  • In this paper, we have developed a new type of single balanced mixer with the RF MEMS $180^{\circ}$ hybrid coupler using surface micromachining technology. The $180^{\circ}$ hybrid coupler in this mixer is composed of the dielectric-supported air gapped microstriplines(DAMLs) which have signal line with $10{\mu}m$ height to reduce substrate dielectric loss and dielectric posts with size of $20{\mu}m{\times}20{\mu}m$ to elevate the signal line on air with stability At LO power of 7.2 dBm, the conversion loss was 15.5 dB f3r RF frequency or 57 GHz and RF power of -15 dBm. Also, we obtained the good RF to LO isolation of -40 dB at LO frequency of 58 GHz and LO power of 7.2 dBm. The main advantage of this type of mixer is that we are able to reduce the size of the chips due to integrating the MEMS passive components.

Performance of a Planar Leaky-Wave Slit Antenna for Different Values of Substrate Thickness

  • Hussain, Niamat;Kedze, Kam Eucharist;Park, Ikmo
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.4
    • /
    • pp.202-207
    • /
    • 2017
  • This paper presents the performance of a planar, low-profile, and wide-gain-bandwidth leaky-wave slit antenna in different thickness values of high-permittivity gallium arsenide substrates at terahertz frequencies. The proposed antenna designs consisted of a periodic array of $5{\times}5$ metallic square patches and a planar feeding structure. The patch array was printed on the top side of the substrate, and the feeding structure, which is an open-ended leaky-wave slot line, was etched on the bottom side of the substrate. The antenna performed as a Fabry-Perot cavity antenna at high thickness levels ($H=160{\mu}m$ and $H=80{\mu}m$), thus exhibiting high gain but a narrow gain bandwidth. At low thickness levels ($H=40{\mu}m$ and $H=20{\mu}m$), it performed as a metasurface antenna and showed wide-gain-bandwidth characteristics with a low gain value. Aside from the advantage of achieving useful characteristics for different antennas by just changing the substrate thickness, the proposed antenna design exhibited a low profile, easy integration into circuit boards, and excellent low-cost mass production suitability.

Modeling and Optimization of $sub-0.1\;{\mu}m$ gate Metamorphic High Electron Mobility Transistors ($0.1\;{\mu}m$ 이하의 게이트 길이를 갖는 Metamorphic High Electron Mobility Transistor의 모델링 및 구조 최적화)

  • Han Min;Kim Sam-Dong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.3 s.333
    • /
    • pp.1-8
    • /
    • 2005
  • In this paper, we analyzed the DC and RF characteristics of $0.1\;{\mu}m$ metamorphic high electron mobility transistor (MHEMT) using the ISE-TCAD simulation tool. we also analyzed the effects or the scaling on vertical and lateral dimensions such as a gate length, source-drain spacing, and channel thickness. We discussed the degradation of extrinsic transconductance $g_{m,max}$ in the MHEMTs adopting the gate length $(L_g)$ of $sub-0.1\;{\mu}m$. We suggested the model describing the effects on the vertical and lateral parameter scaling.

Reliability on the Unintended Trips of Residual Current Operated Circuit Breakers due to Surge Currents (서지전류에 의한 누전차단기의 의도하지 않은 트립에 대한 신뢰성)

  • Lee, Bok-Hee;Kim, Sang-Hyun;Kim, Yoo-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.79-84
    • /
    • 2012
  • As the huge economical loss and function paralysis of information technology-based systems can be caused by the misoperation of residual current devices(RCDs) due to surge voltages and currents, RCDs shall not operate by surge currents. In this paper, in order to evaluate the reliability of residual current operated circuit-breakers with integral overcurrent protection for household and similar uses((RCBOs) stressed by surges, the unintended trip characteristics of RCBOs under surge currents were experimentally investigated using the combination wave generator. Seven different types of single-phase RCBOs being present on the domestic market were investigated according to KS C IEC 61009-1 standard. As a result, all kinds of specimens were satisfied the requirements for 0.5 [${\mu}s$]/100[kHz] ring wave impulse currents. Most of specimens stressed by the 8/20[${\mu}s$] impulse current tripped at least one or more, and some of them were broken down during consecutive tests. It was found that only one type of specimens meets the L-N mode immunity to the combination wave of 1.2/50[${\mu}s$] impulse voltage and 8/20[${\mu}s$] impulse current.

Design of an Energy Harvesting Full-Wave Rectifier Using High-Performance Comparator (고성능 비교기를 이용한 에너지 하베스팅 전파정류회로 설계)

  • Lee, Dong-Jun;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.429-432
    • /
    • 2017
  • In this paper, a full - wave rectifying harvesting circuit with a high-performance comparator is designed. Designed circuits are divided into Negative Voltage Converter and Active Diode stages. The comparator included in the active diode stage is implemented as a 3-stage type and divided into pre-amplification, decision circuit, and output buffer stages. The main purpose of this comparator is to reduce the propagation delay and improve the voltage and power efficiency of the harvesting circuit. The proposed circuit is designed with magna $0.35{\mu}m$ CMOS process and its operation is verified by simulation. The chip area of the designed energy harvesting circuit is $900{\mu}m{\times}712{\mu}m$.

  • PDF

Voltammetric Determination of Dopamine with the N-Hydroxysuccinimide Modified Carbon Paste Electrode (N-히드록시숙신이미드로 수식한 탄소반죽전극을 이용한 도파민의 전기화학적 측정)

  • Yoo Jae Hyun;Yoo Byung Wook;Kim Soon Shin;Uhm Jung Hee;Nam Hakhyun;Cha Geun Sig
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.109-112
    • /
    • 2001
  • An activated carbon paste electrode was modified with the N-Hydroxysuccinimide(NHS) layer and applied to determine the dopamine in the presence of an excess ascorbic acid using square-wave voltammetry. The electrochemical properties of the modified electrode were examined in the solution containing dopamine/ascorbic acid using cyclic voltammetry(CV): the separation between the oxidation peaks of dopamine and ascorbic acid was largely dependent on the pH of the sample solution and became maximum at pH 4.0. Hence, the square-wave voltammetric determination of dopamine was carried out in a pH 4.0, 100mM phosphate buffer saline(PBS) containing 140mM NaCl. The detection limit and response slop were improved from $1.0{\mu}M\;to\;5.0\times10^{-2}{\mu}M\;and\;from\;0.93{\mu}A/{\mu}M\;to\;6.1{\mu}A/{\mu}M$, respectively, upon modification of the electrode surface by NHS.

Development of a Microcurrent acupuncture point treatment equipment (미세전류 경혈치료기의 개발)

  • Jung, Won-Ki;Kim, Young-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2958-2962
    • /
    • 2010
  • We developed a Microcurrent acupuncture point treatment equipment using micro-controller AVR. This equipment can generate a sine wave, triangle wave, square wave and DC. The frequency range of waves like the sine wave and the triangle wave is 1 - 320 Hz and the output range of DC is $40-200\;{\mu}A$. The duration is controllable between a minute to 30 minutes.

Rat Skin Permeation Characteristics of L-cystein to Common Permanent Wave Drug In Vitro (상용 퍼머넌트 웨이브 약제인 L-cystein의 랫드 피부 투과 특성)

  • 김용렬;윤철훈;김낙주
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.73-78
    • /
    • 2001
  • Hair will be persuit of beautifulness of human being in various permanent wave by many kinds of its drugs. Skin is based upon the hair which enroll the body of high living animals and have multiple membrane structure In this study used rat the effects of commercial permanent wave products to skin which are composed with L- cysteine and bases Results are as follow: the content of penetration 4 hors later with steady state and no significant changeable after 20 hours later. In cysteine groups, lag time and permeability coefficient of healthy skin is 2.22hr and 0.13$\mu\textrm{g}$/㎥ hr, lag time and permeability coefficient of old skin is 4.01 hr and 0.108 $\mu\textrm{g}$/㎥ hr . In conclusion of study lag time and permeability coefficient in old skin and wounded skin are faster than healthy skin. We notified that fine rinkle and rash of skin were changeable in the case of treating with permanent wave drugs than normal skin.

  • PDF

Study of Design and Fabrication of GaAs Varactor diode (GaAs 버렉터 다이오드의 설계와 제작에 관한 연구)

  • Choi, Seok-Gyu;Baek, Young-Hyun;Beak, Tea-Jong;Kim, Mi-Ra;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.387-388
    • /
    • 2008
  • In this paper, we have designed and fabricated hyperabrupt varactor diodes. Capacitance variations of hyperabrupt-doped varactor diodes are larger than those of uniform-doped varactor diodes. The measured reverse breakdown voltage of the fabricated varactor diodes was about 20 V. For the anode contact diameter of $50\;{\mu}m$, the maximum capacitance of the fabricated varactor diode was 2.1 pF and the minimum capacitance 0.44 pF. Therefore, the $C_{max}/C_{min}$ ratio was 4.77. Also, for the anode contact diameter of $60\;{\mu}m$, the maximum and minimum capacitances were 2.9 and 0.62 pF, respectively. And, thus, the $C_{max}/C_{min}$ ratio was 4.64.

  • PDF