• Title/Summary/Keyword: Mock-Up Test

Search Result 354, Processing Time 0.036 seconds

Mock-up Test for Field Application of a Polylon Fiber Method (폴리론 화이버 공법의 현장적용을 위한 Mock-up Test)

  • Kwon, Hae-Won;Son, Ho-Jung;Jee, Suk-Won;Lee, Byeong-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.405-408
    • /
    • 2008
  • This study, as mock-up test for applying Polylon Fiber engineering method to the field, analyzed the fundamental characteristics and the fireproof characteristics of high strength concrete mixed with Polylon Fiber 0.05% and the results are summarized as followings. From the characteristic of the fresh concrete, both slump flow and air content were appeared to satisfy target range. And from the characteristic of hardened concrete, all compressive strengths according to the curing conditions were appeared to satisfy design standard strength of 60 MPa. From the fireproof characteristic, small scaling and spalling phenomenon were partially appeared on the surface part of specimens, but generally the excellent fireproof capacities were appeared. From the characteristic of temperature hysteresis, the highest temperature and the average temperature of reinforcing part after fire-resistant test for 3 hours were $531^{\circ}C$ and $405{\circ}C$, respectively and then satisfied fireproof standard of the Ministry of Land Transportation and Maritime Affairs.

  • PDF

Constructability and Economic Evaluation of Continuous Hoop Reinforcement Method

  • Kang, Su-Min;Park, Sung-Woo;Jang, Se-Woong;Jin, Jong-Min;Eom, Tae-Sung;Park, Hong-Gun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.3
    • /
    • pp.291-305
    • /
    • 2013
  • This paper presents the continuous hoop reinforcement method as a means to overcome the difficulty of rebar construction due to the seismic detail of lateral reinforcement. Because the continuous hoop has no seismic hook, and there is less interference during the rebar work, rebar quantities and construction time can be reduced. Since the details of column and beam continuous hoops are different from those of conventional lateral reinforcements, the construction method should be developed through mock-up tests. The length of the beam mock-up is 8m and the section size is $500mm{\times}700mm$, the height of the column mock-up is 2.8m and 4m, and the section size is $800{\times}800mm$. The length and the size are determined based on the elements that are generally used in reinforced concrete basement parking lots and office buildings. The results of the mock-up test showed that the quantities of rebar could be reduced by 20% and the time could be reduced by up to 40% compared with conventional lateral reinforcements.

Field Mock up Test of High Strength Concrete for Busan Lotte Town (부산롯데타운용 고강도 콘크리트 현장 적용을 위한 Mock-up Test)

  • Moon, Hyung-Jae;Park, Soon-Jeon;Heo, Jin-Wook;Koo, Ja-Sul;Jeong, Youn-Sung;Lee, Yang-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.223-224
    • /
    • 2009
  • This study was performed to development 80MPa high strength concrete using local raw material of Busan and to estimate field application ability. As the result of three types of mixture, fresh and hardened properties were satisfied with target requirement properties. Hydration temperature was revealed mean 75$\sim$85$\circ$C. Additionally, in case of compressive strength, core specimen's strength is six times higher than field curing specimen by very high hydration heat.

  • PDF

Autogenous Shrinkage Mock-up Test of High Performance Concrete by Emulsified Refined Cooking Oil (유화처리 정제식용유를 사용한 고성능 콘크리트의 자기수축 Mock-up 실험)

  • Jo, Man-Ki;Han, Cheon-Goo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.307-315
    • /
    • 2016
  • The aim of this research is analyzing the fundamental properties and autogenous shrinkage reducing performance of 70 and 100MPa grade high performance concrete including emusified refined cooking oil(ERCO) under the mock-up conditions. As a results of experiment, the mixture contained 0.5% of ERCO showed slightly decreased slump flow while the slump was increased and segregation resistance performance was improved as 2.5 of EIS. For air content, all mixtures satisfied target air content with increased unit weight and delayed setting time with ERCO addition. In the case of compressive strength, when ERCO was added 0.5%, the result of approximately 5 to 10% of increased compressive strength was observed. For the autogenous shrinkage, ERCO contributed on 20-30% of shrinkage reducing performance comparing to Plain mixture without ERCO. It is considered that capillary pore filling action of soap particles occurred by the reaction of ERCO in cement paste between fatty aicd and calcium hydroxide contributed the shrinkage reducing performance. Based on these mock-up test results, application of the high performance concrete mixture with ERCO on CFT actual structure was decided.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

A Study on the performance test of Water mist system as a fire extinguish system for Ships (선박용 미분무수 소화설비의 성능평가연구)

  • Kim, Sung-Yoon;Ahn, Bung-Ho;Kim, Dong-Seuk;Kim, You-Taek
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.155-156
    • /
    • 2006
  • Developed and conducted a performance test of the Water mist system that is satisfied with the requirement of a fire test requiring Class 3 Engine Mock-up exceeding net volume $3,000m^3$ as per IMO's MSC/Circ. 668 Appendix B(Test method for fire testing equivalent water-based fire-extinguishing systems for machinery spaces of category A and cargo pump rooms).Even though fuel atomizing was continued for 15 sec. after stopping of the system according to the test method relating to the atomizing fire type, no fire was reignited. This result shows the excellence of the system. There was no damage to the contents of the system after the test.

  • PDF

Experimental Study of Floor Impact Sound Insulation by the Finishing Materials and Porous Ratio of Insulations of Floor Structure in Mock-up Test Room (모형실험실에서 바닥충격음 완충재의 발포율 및 바닥마감재의 변화에 따른 충격음 차단성능에 대한 실험적 연구)

  • 김태희;오진균;신일섭;조창근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.756-759
    • /
    • 2003
  • It is increasing the interest on the comfortable dwelling environment and the efforts to solve the problem of the floor impact noise in apartment houses have been realized, as a result numerous products have been made. The purpose of this study is to investigate the sound insulation performances according to foaming rate of floor impact noise insulators and flooring coverings in Mock-up Test Room. The test results of impact insulation performance for each floor impact noise insulators is that double structure of insulator is excel than one in low-middle frequency band and as foaming rate go up, the sound insulation performance is improved.

  • PDF

Study on the Properties of Field Applied Non-Curing Concrete in Winter Season (동절기 무양생 콘크리트의 현장적용 성능 평가에 관한 연구)

  • Yoo, Jo-Hyeong;Kim, Woo-Jae;Hong, Seok-Beom;Kim, Hyeong-Cheol;Lee, Han-Seung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.413-419
    • /
    • 2016
  • In the cold-weathering concrete construction, it is important to ensure stable strength development of concrete in a low temperature environment. In this study, Non-curing cement(NCC) using the classified high fineness cement and self-heating powder was investigated for stable strength development without curing in a low temperature environment (less than $0^{\circ}C$). The actual size Mock-Up tests by various cement type and curing condition are performed to evaluate the strength development and hydration heat of concrete.

Development of a Mock-up of Heaving Line Launcher to Support the Recovery of Unmanned Surface Vehicle (무인선 회수 지원을 위한 히빙라인 발사장치 목업 개발)

  • Kim, Yeon-Gyu;Kim, Sun-Young;Ryu, Gye-Hyoung
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.10a
    • /
    • pp.73-74
    • /
    • 2015
  • In the world the interests about a unmanned surface vehicle(USV) are growing up. However it is difficult to launch and recover a USV because of no men on board of USV. And it is more difficult in recovery than launch of USV. So in this research the heaving line launcher was developed to support the recovery of USV easier. And a mock-up was manufactured to validate for adoption to the USV. The muck-up is composed of launcher pipe, remote trigger, air tank, tow shell and heaving line. Tests in land using the mock-up were carried out. The forces by the heaving line launcher to USV were measured by a measuring table during the tests in land. In this paper the development of a mock-up of heaving line launcher, tests in land and the measured forces during tests are presented.

  • PDF

The Production Process and Mock-up Test of Freeform Concrete Segments using LOM type 3D Printer (LOM 방식 3D 프린터를 이용한 비정형 콘크리트 부재 생산 프로세스 및 Mock-up test)

  • Lee, Dong-Youn;Lee, Dong-Min;Cho, Hun-Hee;Kang, Kyung-In
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.1
    • /
    • pp.89-98
    • /
    • 2018
  • Recently, the importance of the construction technology of the free-formed buildings is becoming more significant, as the interest and demand for the free-formed buildings are increasing. However, it takes much time and cost during the construction of free-formed buildings because the current construction technique of freeform concrete segments is manufactured by a formwork. Therefore, in this study, we suggested a new manufacturing process based on the LOM-type 3D printer for freeform concrete segments that can shorten construction time and reduce cost when constructing freeform concrete segments, and we also verified the feasibility of production process through mock-up test. The result shows that the suggested process shortened 47.8% of production time and saved 56.2% of cost compared to the existing steel formwork method. In conclusion, it is expected that the production method of freeform concrete segments using 3D printer will contribute to the improvement of productivity of freeform concrete segments construction and the activation of new construction method for free-formed building construction.