Browse > Article

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment  

Kim, Jeong Tai (경희대학교 건축공학과)
Shin, Hwa Young (경희대학교 건축공학과)
Publication Information
KIEAE Journal / v.6, no.2, 2006 , pp. 67-74 More about this Journal
Abstract
As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.
Keywords
advanced daylighting system; sloped lightshelf; Mock-up test; daylighting performance; Light factor;
Citations & Related Records
연도 인용수 순위
  • Reference
1 M.A.A.de Almeida Magalhaes, Lightshelves-A Way to Diffuse Direct Solar Light, 1998
2 IEA SHC Task 21, 'Daylighting in Buildings',
3 Soo-Young Kim, 'Analysis of fluctuation light on visual comfort for the applications of daylighting dimming control system', Doctoral Dissertation, University of Mischgan, 2005
4 문기훈, '자연채광성능의 가시화도구로서 Lightscape의 유용성 평가', 경희대학교 박사학위 논문, 2003
5 조일식 외, '축소모형을 이용한 광선반의 시환경 특성 평가연구', 한국태양에너지학회논문집, 제23권 제3호, 2003
6 신현구, '광선반의 채광성능평가에 관한 연구', 경희대학교 석사학위논문, 2003
7 Carlos Ernesto Ochoa et al, 'Evaluating Visusal Comfort and Performance of Three Natural Lighting Systems for Deep Ofiice Buildings in Highly Luminous Climates', Building and Environment, 2004
8 김정태 외, '광반사를 이용한 광선반 채광시스템의 기본형상 설계 및 성능평가에 관한 연구', 대한건축학회논문집 19권 3호, 2003, pp.177-184
9 Santiago-Tomas Claros, 'Indoor daylighting climate- influence of lightshelf and model reflectance on lightshelf performance in Madrid for hours with unit sunshine fraction, 2001
10 William M. C. LAM, 'Sunlighting as Formgiver for Architecture', 1999
11 www.energydesignresource.com
12 www.iea-shc.org
13 M. David Egan, 'Concepts in Architectural Lighting', 1983
14 정인영, '복합투과방식을 적용한 실내환경의 채광성능평가', 경희대학교 박사학위논문, 2004