• 제목/요약/키워드: Mobile radiography

검색결과 15건 처리시간 0.019초

Augmented Reality Technology-based Dental Radiography Simulator for Preclinical Training and Education on Dental Anatomy

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of information and communication convergence engineering
    • /
    • 제17권4호
    • /
    • pp.274-278
    • /
    • 2019
  • It is important that students are provided opportunities to practice their skills in acquiring radiographic images. However, these opportunities are currently limited because of the risk of radiation exposure. To overcome this limitation, a new augmented reality-based radiography simulator was developed that enables students to practice radiographic techniques as part of self-directed learning without time and space constraints. Subsequently, cross-sectional images of a manikin phantom head obtained via computed tomography were reconstructed into a three-dimensional object. An image marker that could be recognized by a mobile device and could allow users to practice dental radiography techniques was devised. The three-dimensional object was augmented to the mobile device; consequently, among 106 stored dental radiographs on the device, a radiograph corresponding to specific imaging conditions was opened when users performed radiographic procedures. This technology could improve dental students' understanding of dental anatomy and contribute to improving their competency in acquiring dental radiographs.

portable 흉부촬영시 공간산란선량에 관한 연구 (A Study on the Scattered Dose in Portable Chest Radiography)

  • 안봉선;이환형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.63-67
    • /
    • 2000
  • The purpose of this study is to survey the present status of portable radiography and the result of free space scattered dose rate when taking a radiography at the general hospital or the university hospital in Taejon city. The results were as follows; 1. The number of cases using portable radiography for three years increased to averages 16.2%, 7.7% per year from January 1st in 1996 to December 31st in 1998. 2. The average of distance of adjacent patients was 219.1 cm at the ward. 3. For portable chest radiography, the free space scattered dose rate was 10.5 mSv/hr at 50 cm distance, 1.8 mSv/hr at 100 cm distance, and 0.2 mSv/hr at 200 cm distance. Therefore, in case of portable chest radiography at the ward, the average of distance of adjacent patients is 219.1 cm, so it does not have influence on the adjacent patients. But during the portable radiography, a guardian who is close to the patient, doctor, nurse and radiologic technologists has to set up the shield to prevent from the unnecessary radiation or the distance should be as great as possible from the mobile X-ray equipment.

  • PDF

영상의학과 이동촬영장비의 감염 관리 (Infection Control of Computed Radiography Portable in Radiology)

  • 신성규;이효영
    • 한국방사선학회논문지
    • /
    • 제11권2호
    • /
    • pp.117-122
    • /
    • 2017
  • 본 연구는 IP 카세트를 이용하는 이동촬영 장비의 세균오염도를 조사하여 이동촬영으로 인한 병원 감염을 예방하고 감염교육의 기초자료를 제공하고자 실시하였다. 결과는 IP Cassette 1번에서 CNS, VRE가 검출되었다. 2번에서는 CNS, 3번에서는 CNS, Pseudomonas aeruginosa, 4번에서는 CNS, 5번에서는 CNS, Bacillus sp., 6번에서는 Enterococcus faecium이 검출되었다. 영상판독기에서는 Enterococcus faecium, Bacillus sp., 장비 이동 손잡이에서 Acinetobacter baumannii, 조작버튼에서는 Bacillus sp., 조사야 조절 손잡이에서는 CNS, Bacillus sp., X-선 발생 스위치에서는 Acinetobacter baumannii, 바코드기 에서는 CNS가 검출되었다. IP Cassette 이동테이블에서는 Bacillus sp. Acinetobacter baumannii, 납 앞치마에서는 CNS, Bacillus sp.가 검출되었다. 방사선사가 촬영 중 착용한 의료용 장갑에서는 Acinetobacter baumannii, CNS가 검출 되었다. 따라서 IP Cassette는 사용 후에는 반드시 소독하고 재사용하며, 영상판독기, IP 이동테이블은 오염된 IP Cassette를 통해 세균이 전파될 수 있으므로 사용 후에는 소독을 실시해야 한다. 환자와 직접 접촉하는 의료용 장갑도 1회 사용 후 교체하고 촬영 시 접촉이 많은 X-발생 스위치, 납 앞치마도 철저히 소독하여 이동촬영으로 인한 감염을 예방하여야 한다.

이동형 X선촬영에서 공간산란선량 분포 측정 (Measurement of the Scattered Spatial Dose Distribution for the Mobile X-ray Radiography)

  • 권덕문;박명환;남효덕
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권1호
    • /
    • pp.23-26
    • /
    • 2001
  • The spatial distribution of the scattered dose for mobile X-ray radiography is measured. The scattered X-ray exposures at the radius of 50, 100 and 150 cm from the irradiation center are 880, 180 and $50\;{\mu}R$, respectively. This scattered X-rays can be reduced to 60% by inserting the portable shield made by 0.4 mm copper sheet sandwiched in two plywoods.

  • PDF

이동형 방사선검사에서 영상의 왜곡과 선량에 관한 연구 (A Study on Distortion and Dose of Images in Mobile Radiography)

  • 송현석;임청환;정홍량;김종성;김영란;정성훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.305-312
    • /
    • 2022
  • The proportion and testing of portable radiation tests, which are limited at the request of the doctor, are gradually increasing only for patients in emergency situations and difficulties in moving. However, as there are many limiting factors compared to fixed devices, this study intends to measure and analyze the distortion of images according to the angle of the detector and the change in dose according to the position of the subject. For distortion experiments using a mobile radiation generator used in Hospital A, the SID was tilted by 110 cm, 14"×17" wireless FPD detector to 0°, -5°, -10°, -15°, -20°, and -35° to measure the change in area. The dose according to the location of the detector was analyzed on average by measuring the central dose at 110 cm of the SID and measuring the dose of 9 locations three times each. The analysis result of distortion by location according to the angle of the detector showed a statistically significant difference (f=58.74, p<0.000). Therefore, it can be seen that the angle of the detector and the tube is closely related to the distortion of the image. The difference in dose by location of the detector increased with respect to the center - pole, and decreased with the + pole. Tests using mobile radiation generators will require careful efforts by clinicians to position patients in the center of the detector for accurate diagnosis, and efforts will be made to level the angle between the mobile radiation generators and the detector.

치과방사선사진과 증강현실을 활용한 방사선촬영법 숙련용 디지털 콘텐츠 개발에 대한 융복합 연구 (Convergence and integration study related to development of digital contents for radiography training using dental radiograph and augmented reality)

  • 구자영;이재기
    • 디지털융복합연구
    • /
    • 제16권12호
    • /
    • pp.441-447
    • /
    • 2018
  • 이 연구의 목적은 증강현실기술을 활용하여 치과 방사선 촬영술의 반복 연습이 가능한 디지털 콘텐츠를 개발하는데 있다. 성인 모델의 외형을 사진 촬영하고, 실습용 마네킹 팬텀을 컴퓨터 단층 촬영한 후, 이를 중첩하여 삼차원 객체를 제작하였다. 또한, 결과로 출력되는 106장의 방사선사진은 촬영법과 관련된 치아 정보를 활용하여 데이터베이스화하였고, 학습자가 성공적인 촬영을 수행하면 각 촬영조건에 맞는 부위별 영상이 호출되도록 시스템을 구축하였다. 이를 통해 임상 전 단계에서의 연습을 반복적으로 시행할 수 있었다. 이 콘텐츠를 이용하여 치과위생사의 방사선 촬영 임상 실무역량을 향상하는데 기여하고자 한다. 다만, 직접 얼굴인식을 통해 촬영하는 것이 실습효용 가치가 클 것으로 예상하기 때문에 이에 관련한 후속 연구가 필요하다.

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

이동형 X선 장치 차폐도구 제작을 통한 표면선량 분포 측정 (Measurement of Skin Dose Distribution for the Mobile X-ray Unit Collimator Shielding Device)

  • 홍선숙;김득용
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.5-8
    • /
    • 2010
  • Opened a court in February 10, 2006, a rule of safety management of the diagnosis radiation system was promulgated for safety of the radiation worker, patients and patients' family members. The purpose of this rule is to minimize the risk of being exposed to radiation during the process of handling X-ray. For this reason, we manufactured shielding device of mobile X-ray unit collimator for diminution of skin dose. Shielding device is made to a thickness of Pb 0.375mm. For portable chest radiography, we measured skin dose 50cm from center ray to 200cm at intervals of 20cm by Unfors Xi detector. As a result, a rule of safety management of the diagnosis radiation system has been strengthened. But there are exceptions, such as ER, OR, ICU to this rule. So shielding device could contribute to protect unnecessary radiation exposure and improve nation's health.

  • PDF

16kW 회전 Aonde형 모노블럭 X-선 발생장치 (A 16kw Rotating Anode type Monoblock X-ray Generator)

  • 오준용;김연충;김학성
    • 전력전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.97-103
    • /
    • 2006
  • 본 논문은 회전형 대용량 진단 X-선 발생장치를 모노 블록 형태로 설계, 병원의 모바일 진단장치나, 산업용 X-선 장치로에 적용이 가능한 16kW급 회전 Anode형 모노블럭 X-선 발생장치에 관한 연구이다. 본 장치는 X-선 발생을 위해 회전 Anode 형의 X-선관을 사용하였고, X-선관의 Anode의 회전을 위한 로터를 구동할 수 있는 로터 구동회로를 추가 하였다. 고주파 고전압용 인버터에는 IGBT(600V/300A)소자를 100kHz로 고주파 스위칭 함으로서 고전압 변압기를 비롯한 고전압 발생부의 크기와 무게를 최소화하였다. 또한, 기존의 16kW급 대용량 진단 X-선 발생장치를 X-선관과 고전압부를 일체화한 모노블록 형태로 설계, 제작하여 부하변동에 따른 X-선 관전압과 관전류의 동작특성을 실험을 통하여 입증하였다.

이동형 디지털 X선 촬영장치의 구축 및 성능평가 (Construction and Performance Evaluation of Digital Radiographic System)

  • 조효민;남소라;이창래;정지영;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.144-148
    • /
    • 2007
  • 최근 국내에서는 원거리에 있는 응급환자에 대한 원격의료서비스를 제공하기 위한 이동형 응급 의료 시스템에 대한 연구가 활발히 진행되고 있다. 본 연구의 목적은 응급구조 차에 탑재 할 수 있는 이동형 디지털 X선 촬영 장치를 구축하고 시스템으로부터 획득한 영상에 대하여 영상 성능평가의 주요인자인 MTF (modulation transfer function), NPS (noise power spectrum) 및 DQE (detective quantum efficiency)를 정량화함으로써 응급상황 시 임상적으로 효용성 있는 영상의 획득 가능성을 평가하는 것이었다. 이동형 X선 장치(Mobix-1000; LISTEM, Wonju, Korea)와 디지털 X선 detector 시스템 (Alpha-R4000; Teleoptic PRA, Kyiv, Ukraine)으로 구축된 영상시스템에 대하여 성능평가를 수행하였다. 측정결과로 10% MTF는 2.4 cycles/mm를 나타내었고, DQE (0)는 조건선량 0.19, 0.5 그리고 1.3 mR에 따라 각각 54%, 55%, 그리고 76%로 측정되었다. 본 연구에서 획득한 영상평가 결과는 연구 중인 이동형 디지털 X선 촬영 장치의 응급 원격 의료에의 사용가치를 확인 할 수 있는 기초자료로서 이용될 수 있을 것으로 판단된다.

  • PDF