이동형 디지털 X선 촬영장치의 구축 및 성능평가

Construction and Performance Evaluation of Digital Radiographic System

  • 조효민 (연세대학교 보건과학대학 방사선학과, 보건과학연구소) ;
  • 남소라 (연세대학교 보건과학대학 방사선학과, 보건과학연구소) ;
  • 이창래 (연세대학교 보건과학대학 방사선학과, 보건과학연구소) ;
  • 정지영 (연세대학교 보건과학대학 방사선학과, 보건과학연구소) ;
  • 김희중 (연세대학교 보건과학대학 방사선학과, 보건과학연구소)
  • Cho, Hyo-Min (Department of Radiological Science, College of Health Science and Research Institute of Health Science, Yonsei University) ;
  • Nam, So-Ra (Department of Radiological Science, College of Health Science and Research Institute of Health Science, Yonsei University) ;
  • Lee, Chang-Lae (Department of Radiological Science, College of Health Science and Research Institute of Health Science, Yonsei University) ;
  • Jung, Ji-Young (Department of Radiological Science, College of Health Science and Research Institute of Health Science, Yonsei University) ;
  • Kim, Hee-Joung (Department of Radiological Science, College of Health Science and Research Institute of Health Science, Yonsei University)
  • 발행 : 2007.09.30

초록

최근 국내에서는 원거리에 있는 응급환자에 대한 원격의료서비스를 제공하기 위한 이동형 응급 의료 시스템에 대한 연구가 활발히 진행되고 있다. 본 연구의 목적은 응급구조 차에 탑재 할 수 있는 이동형 디지털 X선 촬영 장치를 구축하고 시스템으로부터 획득한 영상에 대하여 영상 성능평가의 주요인자인 MTF (modulation transfer function), NPS (noise power spectrum) 및 DQE (detective quantum efficiency)를 정량화함으로써 응급상황 시 임상적으로 효용성 있는 영상의 획득 가능성을 평가하는 것이었다. 이동형 X선 장치(Mobix-1000; LISTEM, Wonju, Korea)와 디지털 X선 detector 시스템 (Alpha-R4000; Teleoptic PRA, Kyiv, Ukraine)으로 구축된 영상시스템에 대하여 성능평가를 수행하였다. 측정결과로 10% MTF는 2.4 cycles/mm를 나타내었고, DQE (0)는 조건선량 0.19, 0.5 그리고 1.3 mR에 따라 각각 54%, 55%, 그리고 76%로 측정되었다. 본 연구에서 획득한 영상평가 결과는 연구 중인 이동형 디지털 X선 촬영 장치의 응급 원격 의료에의 사용가치를 확인 할 수 있는 기초자료로서 이용될 수 있을 것으로 판단된다.

Current digital radiography systems are rapidly glowing in clinical applications. The purpose of this study was to evaluate the characteristics of a mobile digital radiographic system. The performance of the mobile DR system was evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Measurements were made on a LISTEM Mobix-1000 generator and a Teleoptic PRA Alpha-R4000 detector. Imaging characteristics were measured for these two systems using the IEC-61267 defined RQA5 (kVp: 74, additional filtration: 21 mmAl) radiographic condition. The MTF at 10% was measured as 2.4 cycles/mm and the DQE(0) values for radiation exposure 0.19, 0.5, and 1.3 mR were measured as 54%, 55%, and 76%, respectively. The NPS curves gradually decreased at high spatial frequencies. This high DQE at low frequencies, may be useful for low frequency information. The results suggested that mobile DR system could be integrated with emergency ambulance system in teleradiologic imaging applications.

키워드